Boiler controller · BACnet points list
Contemporary Controls Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLX BACnet points list
Updated 12 November 2026
Gateway profile for the Cleaver-Brooks Falcon: 816 objects (121 AI, 440 AO, 115 BI, 140 BO), but only 7 are polled by default (firing rate, fan speed, flame signal, burner run time and three pump outputs). The rest of the Falcon register map is in it: status-change flags, burner control state and lockout code, CH/DHW demand and setpoints, pump status, limits and hundreds of configuration parameters as outputs.
This page lists 816 BACnet objects for the Contemporary Controls Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLX — 580 of them writable — with each object’s type, instance number, name, engineering units and access. It is re-typed from Contemporary Controls’s own free documentation, linked below.
- Manufacturer
- Contemporary Controls
- Model
- Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLX
- Equipment
- Boiler controller
- Equipment type
- Boilers & water heaters
- BACnet objects
- 816 (580 writable)
- Transport
- BACnet IP
- Firmware
- Not stated
- Also known as
- Falcon, CB Falcon, Cleaver Brooks Falcon Modbus, 750-308
Reference only, provided as-is: verify against Contemporary Controls’s current documentation and the live device before use. Not official Contemporary Controls information. Terms of use.
BMS integration notes: Contemporary Controls Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLX
Enable the burner control state, lockout code, outlet temperature and CH setpoint objects before mapping, then write the CH setpoint if the BMS sets it.
Minimum points to map
The short list most integrators start with — enough to run the unit from a BMS. Map more as the job needs.
| Object | Name | Why | Access |
|---|---|---|---|
| AO 276 | CH setpoint | CH setpoint | Command |
| AI 88 | Burner control state | Burner control state | Read |
| AI 69 | Outlet (S3S4) or Outlet limit (S3) sensor | Outlet temperature | Read |
| AI 78 | Active CH setpoint | Active CH setpoint | Read |
| AI 70 | Firing rate | Firing rate | Read |
| AI 72 | Flame signal | Flame signal | Read |
| AI 89 | Lockout code | Lockout code (0 = none) | Read |
| AI 90 | Alarm reason | Alarm reason | Read |
Network setup
- The BASgatewayLX presents each Modbus device as its own virtual BACnet device on BACnet IP; give it a unique device instance and Modbus address (serial) or IP address (Modbus TCP) when you add it with this profile.
- One BASgatewayLX handles up to 100 Modbus devices and 1000 polled points in total, so leave unneeded rows unpolled.
Watch out for
- Most configuration outputs (passwords, rates, limits) live in non-volatile memory; don't write them cyclically.
- Unpolled rows do not appear as BACnet objects until enabled in the gateway's device profile page.
Contemporary Controls Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLX BACnet objects
Type: AI, AO, AV, BI, BO, BV, MI/MO/MV (multi-state) · Access: Read read-only, Write writable, Command writable with a priority array.
Note: the source document has no read/write column, so access here is inferred from the object type (inputs read-only, values writable). Confirm on the live controller before writing.
| Description | States | |||||
|---|---|---|---|---|---|---|
| BI | 1 | Status Change Alert log | Modbus 400001 bit 10; not polled by default | Read | ||
| BI | 2 | Status Change Lockout history | Modbus 400001 bit 9; not polled by default | Read | ||
| BI | 3 | Status Change Lead Lag status | Modbus 400001 bit 8; not polled by default | Read | ||
| BI | 4 | Status Change Statistics | Modbus 400001 bit 7; not polled by default | Read | ||
| BI | 5 | Status Change Pump status | Modbus 400001 bit 6; not polled by default | Read | ||
| BI | 6 | Status Change DHW status | Modbus 400001 bit 5; not polled by default | Read | ||
| BI | 7 | Status Change CH status | Modbus 400001 bit 4; not polled by default | Read | ||
| BI | 8 | Status Change Demand Modulation status | Modbus 400001 bit 3; not polled by default | Read | ||
| BI | 9 | Status Change Sensor status | Modbus 400001 bit 2; not polled by default | Read | ||
| BI | 10 | Status Change Burner control status | Modbus 400001 bit 1; not polled by default | Read | ||
| BI | 11 | Status Change Active Lockout | Modbus 400001 bit 0; not polled by default | Read | ||
| BI | 12 | Configuration Change PCB configuration | Modbus 400002 bit 15; not polled by default | Read | ||
| BI | 13 | Configuration Change PIM configuration | Modbus 400002 bit 14; not polled by default | Read | ||
| BI | 14 | Configuration Change Lead Lag configuration | Modbus 400002 bit 12; not polled by default | Read | ||
| BI | 15 | Configuration Change Frost protection configuration | Modbus 400002 bit 11; not polled by default | Read | ||
| BI | 16 | Configuration Change Outdoor reset configuration | Modbus 400002 bit 10; not polled by default | Read | ||
| BI | 17 | Configuration Change Anti-condensation configuration | Modbus 400002 bit 9; not polled by default | Read | ||
| BI | 18 | Configuration Change limits configuration | Modbus 400002 bit 8; not polled by default | Read | ||
| BI | 19 | Configuration Change DHW configuration | Modbus 400002 bit 7; not polled by default | Read | ||
| BI | 20 | Configuration Change Annunciation configuration | Modbus 400002 bit 6; not polled by default | Read | ||
| BI | 21 | Configuration Change Pump configuration | Modbus 400002 bit 5; not polled by default | Read | ||
| BI | 22 | Configuration Change Fan configuration | Modbus 400002 bit 4; not polled by default | Read | ||
| BI | 23 | Configuration ChangeB urner control configuration | Modbus 400002 bit 3; not polled by default | Read | ||
| BI | 24 | Configuration Change CH configuration | Modbus 400002 bit 2; not polled by default | Read | ||
| BI | 25 | Configuration Change Modulation configuration | Modbus 400002 bit 1; not polled by default | Read | ||
| BI | 26 | Configuration Change System configuration | Modbus 400002 bit 0; not polled by default | Read | ||
| BI | 27 | Configuration Change Safety relay | Modbus 400003 bit 15; not polled by default | Read | ||
| BI | 28 | Configuration Change Time of Day | Modbus 400003 bit 14; not polled by default | Read | ||
| BI | 29 | Configuration Change STAT (Demand) | Modbus 400003 bit 13; not polled by default | Read | ||
| BI | 30 | Configuration Change High Fire Switch (HFS) | Modbus 400003 bit 12; not polled by default | Read | ||
| BI | 31 | Configuration Change Low Fire Switch (LFS) | Modbus 400003 bit 11; not polled by default | Read | ||
| BI | 32 | Configuration Change Load Control Input(LCI) | Modbus 400003 bit 10; not polled by default | Read | ||
| BI | 33 | Configuration Change Pre-ignition interlock (PII) | Modbus 400003 bit 9; not polled by default | Read | ||
| BI | 34 | Configuration Change Interlock (ILK) | Modbus 400003 bit 8; not polled by default | Read | ||
| BI | 35 | Configuration Change Alarm | Modbus 400003 bit 7; not polled by default | Read | ||
| BI | 36 | Configuration Change Main valve | Modbus 400003 bit 6; not polled by default | Read | ||
| BI | 37 | Configuration Change Pilot valve | Modbus 400003 bit 5; not polled by default | Read | ||
| BI | 38 | Configuration Change External ignition | Modbus 400003 bit 4; not polled by default | Read | ||
| BI | 39 | Configuration Change Blower motor/HSI | Modbus 400003 bit 3; not polled by default | Read | ||
| BI | 40 | Configuration Change Pump C | Modbus 400003 bit 2; not polled by default | Read | ||
| BI | 41 | Configuration Change Pump B | Modbus 400003 bit 1; not polled by default | Read | ||
| BI | 42 | Configuration Change Pump A | Modbus 400003 bit 0; not polled by default | Read | ||
| BI | 43 | Annunciation I/O Annunciator 8/LFS | Modbus 400004 bit 7; not polled by default | Read | ||
| BI | 44 | Annunciation I/O Annunciator 7/HFS | Modbus 400004 bit 6; not polled by default | Read | ||
| BI | 45 | Annunciation I/O Annunciator 6 | Modbus 400004 bit 5; not polled by default | Read | ||
| BI | 46 | Annunciation I/O Annunciator 5 | Modbus 400004 bit 4; not polled by default | Read | ||
| BI | 47 | Annunciation I/O Annunciator 4 | Modbus 400004 bit 3; not polled by default | Read | ||
| BI | 48 | Annunciation I/O Annunciator 3 | Modbus 400004 bit 2; not polled by default | Read | ||
| BI | 49 | Annunciation I/O Annunciator 2 | Modbus 400004 bit 1; not polled by default | Read | ||
| BI | 50 | Annunciation I/O Annunciator 1/IAS | Modbus 400004 bit 0; not polled by default | Read | ||
| BI | 51 | Limits Heat exchanger high limit | Modbus 400005 bit 11; not polled by default | Read | ||
| BI | 52 | Limits Exchanger T-rise limit | Modbus 400005 bit 10; not polled by default | Read | ||
| BI | 53 | Limits Outlet T-rise limit | Modbus 400005 bit 9; not polled by default | Read | ||
| BI | 54 | Limits Inversion inlet/exchanger limit | Modbus 400005 bit 8; not polled by default | Read | ||
| BI | 55 | Limits Inversion exchanger/outlet limit | Modbus 400005 bit 7; not polled by default | Read | ||
| BI | 56 | Limits Inversion inlet/outlet limit | Modbus 400005 bit 6; not polled by default | Read | ||
| BI | 57 | Limits Delta T inlet/exchanger limit | Modbus 400005 bit 5; not polled by default | Read | ||
| BI | 58 | Limits Delta T exchanger/outlet limit | Modbus 400005 bit 4; not polled by default | Read | ||
| BI | 59 | Limits Delta T inlet/outlet limit | Modbus 400005 bit 3; not polled by default | Read | ||
| BI | 60 | Limits Stack limit | Modbus 400005 bit 2; not polled by default | Read | ||
| BI | 61 | Limits DHW high limit | Modbus 400005 bit 1; not polled by default | Read | ||
| BI | 62 | Limits Outlet high limit | Modbus 400005 bit 10; not polled by default | Read | ||
| BI | 63 | Plug-In Module (PIM) Status OEM alert PCB stored in PIM | Modbus 400006 bit 9; not polled by default | Read | ||
| BI | 64 | Plug-In Module (PIM) Status OEM range PCB stored in PIM | Modbus 400006 bit 8; not polled by default | Read | ||
| BI | 65 | Plug-In Module (PIM) Status Valid copyright | Modbus 400006 bit 2; not polled by default | Read | ||
| BI | 66 | Plug-In Module (PIM) Status Lead/Lag enabled | Modbus 400006 bit 1; not polled by default | Read | ||
| BI | 67 | Plug-In Module (PIM) Status PIM installed | Modbus 400006 bit 0; not polled by default | Read | ||
| AI | 68 | Demand source | Modbus 400007; not polled by default | Read | ||
| AImin | 69 | Outlet (S3S4) or Outlet limit (S3) sensor | Modbus 400008; not polled by default | °C | Read | |
| AImin | 70 | Firing rate | Modbus 400009 | Read | ||
| AI | 71 | Fan speed | Modbus 400010 | rpm | Read | |
| AImin | 72 | Flame signal | Modbus 400011 | V | Read | |
| AI | 73 | Inlet (S1) sensor | Modbus 400012; not polled by default | °C | Read | |
| AI | 74 | DHW (S6S7) or DHW limit (S6) sensor | Modbus 400013; not polled by default | °C | Read | |
| AI | 75 | S5 sensor | Modbus 400014; not polled by default | °C | Read | |
| AI | 76 | Stack (S8S9) or Stack limit (S8) sensor | Modbus 400015; not polled by default | °C | Read | |
| AI | 77 | 4-20 mA remote control input (S2) terminal | Modbus 400016; not polled by default | mA | Read | |
| AImin | 78 | Active CH setpoint | Modbus 400017; not polled by default | °C | Read | |
| AI | 79 | Active DHW setpoint | Modbus 400018; not polled by default | °C | Read | |
| AI | 80 | Active LL setpoint | Modbus 400019; not polled by default | °C | Read | |
| AO | 81 | Register Access Status | Modbus 400020; not polled by default | Command | ||
| AI | 82 | Steam pressure | Modbus 400021; not polled by default | psi | Read | |
| AI | 83 | Analog modulation input | Modbus 400022; not polled by default | Read | ||
| AI | 84 | Active CH pressure setpoint | Modbus 400023; not polled by default | Read | ||
| BI | 85 | Extended Status Change DHW plate heat exchanger configuration | Modbus 400024 bit 4; not polled by default | Read | ||
| BI | 86 | Extended Status Change DHW plate heat exchanger status | Modbus 400024 bit 3; not polled by default | Read | ||
| AI | 87 | Burner control status | Modbus 400033; not polled by default | Read | ||
| AImin | 88 | Burner control state | Modbus 400034; not polled by default | Read | ||
| AImin | 89 | Lockout code | Modbus 400035; not polled by default | Read | ||
| AImin | 90 | Alarm reason | Modbus 400036; not polled by default | Read | ||
| AI | 91 | Annunciator first out | Modbus 400037; not polled by default | Read | ||
| AI | 92 | Annunciator hold | Modbus 400038; not polled by default | Read | ||
| AI | 93 | Sequence time | Modbus 400039; not polled by default | s | Read | |
| AI | 94 | Delay time | Modbus 400040; not polled by default | s | Read | |
| AI | 95 | Hold code | Modbus 400041; not polled by default | Read | ||
| AI | 96 | Burner control flags | Modbus 400042; not polled by default | Read | ||
| AI | 97 | Remote Stat | Modbus 400043; not polled by default | Read | ||
| AI | 98 | Outlet operation (S4=J8-10) terminal | Modbus 400044; not polled by default | °C | Read | |
| AI | 99 | DHW operation (S7=J9-3) terminal | Modbus 400045; not polled by default | °C | Read | |
| AI | 100 | Stack or Heat exchanger operation (S9=J9-6) | Modbus 400046; not polled by default | °C | Read | |
| AI | 101 | Outlet operation sensor (S4=J8-10) state | Modbus 400047; not polled by default | Read | ||
| AI | 102 | DHW operation sensor (S7=J9-3) state | Modbus 400048; not polled by default | Read | ||
| AI | 103 | Outlet limit sensor (S3=J8-8) State | Modbus 400049; not polled by default | Read | ||
| AI | 104 | Inlet sensor (S1=J8-4) state | Modbus 400050; not polled by default | Read | ||
| AI | 105 | DHW limit sensor (S7=J9-1) State | Modbus 400051; not polled by default | Read | ||
| AI | 106 | Stack limit sensor (S8=J9-4) State | Modbus 400052; not polled by default | Read | ||
| AI | 107 | S5 (J8-11) sensor state | Modbus 400053; not polled by default | Read | ||
| AI | 108 | 4-20mA remote control input(S2=J8-6) state | Modbus 400054; not polled by default | Read | ||
| AI | 109 | Pressure sensor (S1=J8-4) state | Modbus 400055; not polled by default | Read | ||
| AI | 110 | Stack operation or Heat exchanger sensor (S9=J9-6) State | Modbus 400056; not polled by default | Read | ||
| AI | 111 | Active rate limiter | Modbus 400057; not polled by default | Read | ||
| AI | 112 | Limited rate | Modbus 400058; not polled by default | Read | ||
| AI | 113 | Active rate override | Modbus 400059; not polled by default | Read | ||
| AI | 114 | Override rate | Modbus 400060; not polled by default | Read | ||
| AI | 115 | Demand rate | Modbus 400064; not polled by default | Read | ||
| AI | 116 | CH status | Modbus 400065; not polled by default | Read | ||
| AI | 117 | CH setpoint source | Modbus 400066; not polled by default | Read | ||
| AI | 118 | CH heat demand | Modbus 400067; not polled by default | Read | ||
| AI | 119 | CH burner demand | Modbus 400068; not polled by default | Read | ||
| AI | 120 | CH requested rate | Modbus 400069; not polled by default | Read | ||
| AI | 121 | CH frost heat demand | Modbus 400070; not polled by default | Read | ||
| AI | 122 | CH frost burner demand | Modbus 400071; not polled by default | Read | ||
| AI | 123 | Active CH on hysteresis | Modbus 400072; not polled by default | °C | Read | |
| AI | 124 | Active CH off hysteresis | Modbus 400073; not polled by default | °C | Read | |
| AI | 125 | Active CH pressure on hysteresis | Modbus 400074; not polled by default | psi | Read | |
| AI | 126 | Active CH pressure off hysteresis | Modbus 400075; not polled by default | psi | Read | |
| AI | 127 | DHW status | Modbus 400081; not polled by default | Read | ||
| AI | 128 | DHW setpoint source | Modbus 400082; not polled by default | Read | ||
| AI | 129 | DHW priority count | Modbus 400083; not polled by default | s | Read | |
| AI | 130 | DHW heat demand | Modbus 400084; not polled by default | Read | ||
| AI | 131 | DHW burner demand | Modbus 400085; not polled by default | Read | ||
| AI | 132 | DHW requested rate | Modbus 400086; not polled by default | Read | ||
| AI | 133 | DHW frost heat demand | Modbus 400087; not polled by default | Read | ||
| AI | 134 | DHW frost burner demand | Modbus 400088; not polled by default | Read | ||
| AI | 135 | Active DHW on hysteresis | Modbus 400089; not polled by default | °C | Read | |
| AI | 136 | Active DHW off hysteresis | Modbus 400090; not polled by default | °C | Read | |
| AI | 137 | DHW storage time | Modbus 400091; not polled by default | s | Read | |
| AI | 138 | DHW storage heat demand | Modbus 400092; not polled by default | Read | ||
| AI | 139 | DHW storage burner demand | Modbus 400093; not polled by default | Read | ||
| BI | 140 | Pump A status Auxiliary 2 pump demand | Modbus 400094 bit 13; not polled by default | Read | ||
| BI | 141 | Pump A status Auxiliary 1 pump demand | Modbus 400094 bit 12; not polled by default | Read | ||
| BI | 142 | Pump A status System pump demand | Modbus 400094 bit 11; not polled by default | Read | ||
| BI | 143 | Pump A status Boiler pump demand | Modbus 400094 bit 10; not polled by default | Read | ||
| BI | 144 | Pump A status DHW pump demand | Modbus 400094 bit 9; not polled by default | Read | ||
| BI | 145 | Pump A status CH pump demand | Modbus 400094 bit 8; not polled by default | Read | ||
| BI | 146 | Pump A status Pump assigned to logical pump | Modbus 400094 bit 6; not polled by default | Read | ||
| BI | 147 | Pump A status Pump exercise requested | Modbus 400094 bit 5; not polled by default | Read | ||
| BI | 148 | Pump A status On due to exercise | Modbus 400094 bit 4; not polled by default | Read | ||
| BI | 149 | Pump A status On due to overrun | Modbus 400094 bit 3; not polled by default | Read | ||
| BI | 150 | Pump A status Forced off | Modbus 400094 bit 2; not polled by default | Read | ||
| BI | 151 | Pump A status Forced on | Modbus 400094 bit 1; not polled by default | Read | ||
| BI | 152 | Pump A status On due to normal demand | Modbus 400094 bit 0; not polled by default | Read | ||
| BI | 153 | Pump B status Auxiliary 1 pump demand | Modbus 400095 bit 12; not polled by default | Read | ||
| BI | 154 | Pump B status System pump demand | Modbus 400095 bit 11; not polled by default | Read | ||
| BI | 155 | Pump B status Boiler pump demand | Modbus 400095 bit 10; not polled by default | Read | ||
| BI | 156 | Pump B status DHW pump demand | Modbus 400095 bit 9; not polled by default | Read | ||
| BI | 157 | Pump B status CH pump demand | Modbus 400095 bit 8; not polled by default | Read | ||
| BI | 158 | Pump B status Pump Bssigned to logical pump | Modbus 400095 bit 6; not polled by default | Read | ||
| BI | 159 | Pump B status Pump exercise requested | Modbus 400095 bit 5; not polled by default | Read | ||
| BI | 160 | Pump B status On due to exercise | Modbus 400095 bit 4; not polled by default | Read | ||
| BI | 161 | Pump B status On due to overrun | Modbus 400095 bit 3; not polled by default | Read | ||
| BI | 162 | Pump B status Forced off | Modbus 400095 bit 2; not polled by default | Read | ||
| BI | 163 | Pump B status Forced on | Modbus 400095 bit 1; not polled by default | Read | ||
| BI | 164 | Pump B status On due to normal demand | Modbus 400095 bit 0; not polled by default | Read | ||
| AI | 165 | CH pump start delay time | Modbus 400096; not polled by default | Read | ||
| AI | 166 | CH pump status | Modbus 400097; not polled by default | Read | ||
| AI | 167 | CH pump overrun time | Modbus 400098; not polled by default | s | Read | |
| AI | 168 | CH FP overrun time | Modbus 400099; not polled by default | s | Read | |
| AI | 169 | CH pump idle days count | Modbus 400100; not polled by default | days | Read | |
| AI | 170 | DHW pump status | Modbus 400101; not polled by default | Read | ||
| AI | 171 | DHW pump start delay time | Modbus 400102; not polled by default | s | Read | |
| AI | 172 | DHW pump overrun time | Modbus 400103; not polled by default | s | Read | |
| AI | 173 | DHW FP overrun time | Modbus 400104; not polled by default | s | Read | |
| AI | 174 | DHW pump idle days count | Modbus 400105; not polled by default | days | Read | |
| AI | 175 | System pump status | Modbus 400106; not polled by default | Read | ||
| AI | 176 | System pump overrun time | Modbus 400107; not polled by default | s | Read | |
| AI | 177 | System pump idle days count | Modbus 400108; not polled by default | days | Read | |
| AI | 178 | Boiler pump status | Modbus 400109; not polled by default | Read | ||
| AI | 179 | Boiler pump overrun time | Modbus 400110; not polled by default | s | Read | |
| AI | 180 | Boiler pump idle days count | Modbus 400111; not polled by default | days | Read | |
| AI | 181 | Auxiliary 1 pump status | Modbus 400112; not polled by default | Read | ||
| AI | 182 | Auxiliary 1 pump idle days count | Modbus 400113; not polled by default | days | Read | |
| AI | 183 | Auxiliary 2 pump status | Modbus 400114; not polled by default | Read | ||
| AI | 184 | Auxiliary 2 pump overrun time | Modbus 400115; not polled by default | s | Read | |
| AI | 185 | Auxiliary 2 pump idle days count | Modbus 400116; not polled by default | days | Read | |
| AI | 186 | Auxiliary 1 pump overrun time | Modbus 400120; not polled by default | s | Read | |
| AO | 187 | Burner cycle count | Modbus 400129; not polled by default | Command | ||
| AO | 188 | Burner run time | Modbus 400131 | h | Command | |
| AO | 189 | CH pump cycle count | Modbus 400133; not polled by default | Command | ||
| AO | 190 | DHW pump cycle count | Modbus 400135; not polled by default | Command | ||
| AO | 191 | System pump cycle count | Modbus 400137; not polled by default | Command | ||
| AO | 192 | Boiler pump cycle count | Modbus 400139; not polled by default | Command | ||
| AO | 193 | Auxiliary pump cycle count | Modbus 400141; not polled by default | Command | ||
| AO | 194 | Controller cycle count | Modbus 400143; not polled by default | Command | ||
| AI | 195 | Controller run time | Modbus 400145; not polled by default | h | Read | |
| AI | 196 | Auxiliary 2 pump cycle count R/W | Modbus 400147; not polled by default | Read | ||
| AI | 197 | Auxiliary 2 pump start delay time | Modbus 400149; not polled by default | Read | ||
| AI | 198 | Boiler pump start delay time | Modbus 400150; not polled by default | Read | ||
| AI | 199 | System pump start delay time | Modbus 400151; not polled by default | Read | ||
| AI | 200 | Auxiliary 1 pump start delay time | Modbus 400152; not polled by default | Read | ||
| AI | 201 | DHW tap heat demand | Modbus 400153; not polled by default | Read | ||
| AI | 202 | DHW preheat demand | Modbus 400154; not polled by default | Read | ||
| AI | 203 | DHW change rate | Modbus 400155; not polled by default | Read | ||
| AI | 204 | DHW tap on recognition time | Modbus 400156; not polled by default | Read | ||
| AI | 205 | DHW tap on time | Modbus 400157; not polled by default | Read | ||
| AI | 206 | DHW preheat delay after tap time | Modbus 400158; not polled by default | Read | ||
| AI | 207 | DHW preheat on recognition time | Modbus 400159; not polled by default | Read | ||
| AI | 208 | DHW preheat on time | Modbus 400160; not polled by default | Read | ||
| AI | 209 | Lead Lag master status | Modbus 400161; not polled by default | Read | ||
| BI | 210 | Lead Lag slave status Slave command received | Modbus 400162 bit 15; not polled by default | Read | ||
| BI | 211 | Lead Lag slave status Slave mode has priority over CH DHW | Modbus 400162 bit 14; not polled by default | Read | ||
| BI | 212 | Lead Lag slave status Slave is modulating | Modbus 400162 bit 13; not polled by default | Read | ||
| BI | 213 | Lead Lag slave status CH frost protection request | Modbus 400162 bit 12; not polled by default | Read | ||
| BI | 214 | Lead Lag slave status DHW frost protection request | Modbus 400162 bit 11; not polled by default | Read | ||
| BI | 215 | Lead Lag slave status Frost protection burner request | Modbus 400162 bit 10; not polled by default | Read | ||
| BI | 216 | Lead Lag slave status Local frost protection request | Modbus 400162 bit 9; not polled by default | Read | ||
| BI | 217 | Lead Lag slave status Burner control status (see register 32) | Modbus 400162 bit 7; not polled by default | Read | ||
| AI | 218 | Lead Lag master setpoint source | Modbus 400163; not polled by default | Read | ||
| AI | 219 | Lead Lag master heat demand | Modbus 400164; not polled by default | Read | ||
| AI | 220 | Lead Lag slave burner demand | Modbus 400165; not polled by default | Read | ||
| AI | 221 | Lead Lag slave requested rate | Modbus 400166; not polled by default | Read | ||
| BI | 222 | Pump C status Auxiliary 2 pump demand | Modbus 400169 bit 13; not polled by default | Read | ||
| BI | 223 | Pump C status Auxiliary 1 pump demand | Modbus 400169 bit 12; not polled by default | Read | ||
| BI | 224 | Pump C status System pump demand | Modbus 400169 bit 11; not polled by default | Read | ||
| BI | 225 | Pump C status Boiler pump demand | Modbus 400169 bit 10; not polled by default | Read | ||
| BI | 226 | Pump C status DHW pump demand | Modbus 400169 bit 9; not polled by default | Read | ||
| BI | 227 | Pump C status CH pump demand | Modbus 400169 bit 8; not polled by default | Read | ||
| BI | 228 | Pump C status Pump assigned to logical pump | Modbus 400169 bit 6; not polled by default | Read | ||
| BI | 229 | Pump C status Pump exercise requested | Modbus 400169 bit 5; not polled by default | Read | ||
| BI | 230 | Pump C status On due to exercise | Modbus 400169 bit 4; not polled by default | Read | ||
| BI | 231 | Pump C status On due to overrun | Modbus 400169 bit 3; not polled by default | Read | ||
| BI | 232 | Pump C status Forced off | Modbus 400169 bit 2; not polled by default | Read | ||
| BI | 233 | Pump C status Forced on | Modbus 400169 bit 1; not polled by default | Read | ||
| BI | 234 | Pump C status On due to normal demand | Modbus 400169 bit 0; not polled by default | Read | ||
| AI | 235 | Outdoor temperature | Modbus 400171; not polled by default | °C | Read | |
| AI | 236 | Outdoor sensor state | Modbus 400172; not polled by default | Read | ||
| AI | 237 | Outlet T-rise rate | Modbus 400173; not polled by default | Read | ||
| AI | 238 | Exchanger T-rise rate | Modbus 400174; not polled by default | Read | ||
| AI | 239 | S10 sensor reading | Modbus 400175; not polled by default | °C | Read | |
| AI | 240 | S10 sensor state | Modbus 400176; not polled by default | Read | ||
| AI | 241 | Product type | Modbus 400177; not polled by default | Read | ||
| AO | 242 | Password | Modbus 400178; not polled by default | Command | ||
| AO | 243 | Temperature units | Modbus 400179; not polled by default | Command | ||
| AO | 244 | Antishort cycle time | Modbus 400180; not polled by default | s | Command | |
| AO | 245 | Alarm silence time | Modbus 400181; not polled by default | min | Command | |
| AO | 246 | Power up with lockout | Modbus 400182; not polled by default | Command | ||
| AO | 247 | Reset and restart | Modbus 400183; not polled by default | Command | ||
| AO | 248 | Burner name | Modbus 400184; not polled by default | Command | ||
| AO | 249 | Installation data | Modbus 400185; not polled by default | Command | ||
| AO | 250 | OEM ID | Modbus 400186; not polled by default | Command | ||
| AI | 251 | OS number | Modbus 400187; not polled by default | Read | ||
| AI | 252 | Date code | Modbus 400188; not polled by default | Read | ||
| AI | 253 | Safety Processor build | Modbus 400189; not polled by default | Read | ||
| AI | 254 | Application Processor build | Modbus 400190; not polled by default | Read | ||
| AO | 255 | Installer password | Modbus 400191; not polled by default | Command | ||
| AO | 256 | OEM password | Modbus 400192; not polled by default | Command | ||
| AO | 257 | Modulation output | Modbus 400193; not polled by default | Command | ||
| AO | 258 | CH maximum modulation rate | Modbus 400194; not polled by default | Command | ||
| AO | 259 | DHW maximum modulation rate | Modbus 400195; not polled by default | Command | ||
| AO | 260 | Minimum modulation rate | Modbus 400196; not polled by default | Command | ||
| AO | 261 | Prepurge rate | Modbus 400197; not polled by default | Command | ||
| AO | 262 | Lightoff rate | Modbus 400198; not polled by default | Command | ||
| AO | 263 | Postpurge rate | Modbus 400199; not polled by default | Command | ||
| AO | 264 | CH forced rate | Modbus 400200; not polled by default | Command | ||
| AO | 265 | CH forced rate time | Modbus 400201; not polled by default | s | Command | |
| AO | 266 | DHW forced rate | Modbus 400202; not polled by default | Command | ||
| AO | 267 | DHW forced rate time | Modbus 400203; not polled by default | s | Command | |
| AO | 268 | Burner switch | Modbus 400204; not polled by default | Command | ||
| AO | 269 | Firing rate control | Modbus 400205; not polled by default | Command | ||
| AO | 270 | Manual firing rate | Modbus 400206; not polled by default | Command | ||
| AO | 271 | Analog output hysteresis | Modbus 400207; not polled by default | Command | ||
| AO | 272 | Standby rate | Modbus 400208; not polled by default | Command | ||
| AO | 273 | CH enable | Modbus 400209; not polled by default | Command | ||
| AO | 274 | CH demand switch | Modbus 400210; not polled by default | Command | ||
| AO | 275 | CH modulation sensor | Modbus 400211; not polled by default | Command | ||
| AOmin | 276 | CH setpoint | Modbus 400212; not polled by default | °C | Command | |
| AO | 277 | CH time of day setpoint | Modbus 400213; not polled by default | °C | Command | |
| AO | 278 | CH on hysteresis | Modbus 400214; not polled by default | Command | ||
| AO | 279 | CH off hysteresis | Modbus 400215; not polled by default | Command | ||
| AO | 280 | CH outdoor reset enable | Modbus 400216; not polled by default | Command | ||
| AO | 281 | CH P-gain | Modbus 400217; not polled by default | Command | ||
| AO | 282 | CH I-gain | Modbus 400218; not polled by default | Command | ||
| AO | 283 | CH D-gain | Modbus 400219; not polled by default | Command | ||
| AO | 284 | CH hysteresis step time | Modbus 400220; not polled by default | s | Command | |
| AO | 285 | CH pressure setpoint | Modbus 400221; not polled by default | psi | Command | |
| AO | 286 | CH pressure on hysteresis | Modbus 400222; not polled by default | psi | Command | |
| AO | 287 | CH pressure off hysteresis | Modbus 400224; not polled by default | psi | Command | |
| AO | 288 | Ignition source | Modbus 400225; not polled by default | Command | ||
| AO | 289 | BLR/HSI function | Modbus 400226; not polled by default | Command | ||
| AO | 290 | Igniter on during | Modbus 400227; not polled by default | Command | ||
| AO | 291 | Pilot type | Modbus 400228; not polled by default | Command | ||
| AO | 292 | Flame sensor type | Modbus 400229; not polled by default | Command | ||
| AO | 293 | Purge rate proving | Modbus 400230; not polled by default | Command | ||
| AO | 294 | Lightoff rate proving | Modbus 400231; not polled by default | Command | ||
| AO | 295 | Prepurge time | Modbus 400232; not polled by default | s | Command | |
| AO | 296 | Pre-ignition time | Modbus 400233; not polled by default | Command | ||
| AO | 297 | Pilot flame establishing period (PFEP) | Modbus 400234; not polled by default | Command | ||
| AO | 298 | Main flame establishing period (MFEP) | Modbus 400235; not polled by default | Command | ||
| AO | 299 | Run stabilization time | Modbus 400236; not polled by default | s | Command | |
| AO | 300 | Postpurge time | Modbus 400237; not polled by default | s | Command | |
| AO | 301 | Interlock start check enable | Modbus 400238; not polled by default | Command | ||
| AO | 302 | Interlock open response | Modbus 400239; not polled by default | Command | ||
| AO | 303 | Ignite failure response | Modbus 400240; not polled by default | Command | ||
| AO | 304 | Ignite failure retries | Modbus 400241; not polled by default | Command | ||
| AO | 305 | Ignite failure delay | Modbus 400242; not polled by default | s | Command | |
| AO | 306 | MFEP flame failure response | Modbus 400243; not polled by default | Command | ||
| AO | 307 | Run flame failure response | Modbus 400244; not polled by default | Command | ||
| AO | 308 | Pilot test hold | Modbus 400245; not polled by default | Command | ||
| AO | 309 | Interrupted air switch (IAS) enable | Modbus 400247; not polled by default | Command | ||
| AO | 310 | IAS start check enable | Modbus 400248; not polled by default | Command | ||
| AO | 311 | LCI enable | Modbus 400249; not polled by default | Command | ||
| AO | 312 | PII enable | Modbus 400250; not polled by default | Command | ||
| AO | 313 | Flame threshold | Modbus 400251; not polled by default | Command | ||
| AO | 314 | ILK bounce detection | Modbus 400254; not polled by default | Command | ||
| AO | 315 | Forced recycle interval time | Modbus 400255; not polled by default | Command | ||
| AO | 316 | Absolute maximum fan speed | Modbus 400257; not polled by default | rpm | Command | |
| AO | 317 | Absolute minimum fan speed | Modbus 400258; not polled by default | rpm | Command | |
| AO | 318 | Fan PWM frequency | Modbus 400259; not polled by default | Command | ||
| AO | 319 | Fan pulses per revolution | Modbus 400260; not polled by default | Command | ||
| AO | 320 | Fan speed-up ramp | Modbus 400261; not polled by default | Command | ||
| AO | 321 | Fan slow-down ramp | Modbus 400262; not polled by default | Command | ||
| AO | 322 | Fan gain up | Modbus 400263; not polled by default | Command | ||
| AO | 323 | Fan gain down | Modbus 400264; not polled by default | Command | ||
| AO | 324 | Fan minimum duty cycle | Modbus 400265; not polled by default | Command | ||
| AO | 325 | CH pump output | Modbus 400273; not polled by default | Command | ||
| AO | 326 | CH pump control | Modbus 400274; not polled by default | Command | ||
| AO | 327 | CH pump overrun time | Modbus 400275; not polled by default | s | Command | |
| AO | 328 | CH FP pump overrun time | Modbus 400276; not polled by default | s | Command | |
| AO | 329 | DHW pump output | Modbus 400277; not polled by default | Command | ||
| AO | 330 | DHW pump control | Modbus 400278; not polled by default | Command | ||
| AO | 331 | DHW pump overrun time | Modbus 400279; not polled by default | s | Command | |
| AO | 332 | DHW FP pump overrun time R/W | Modbus 400280; not polled by default | s | Command | |
| AO | 333 | DHW pump start delay | Modbus 400281; not polled by default | s | Command | |
| AO | 334 | Boiler pump output | Modbus 400282 | Command | ||
| AO | 335 | Boiler pump control | Modbus 400283; not polled by default | Command | ||
| AO | 336 | Boiler pump overrun time | Modbus 400284; not polled by default | s | Command | |
| AO | 337 | Auxiliary 1 pump output | Modbus 400285 | Command | ||
| AO | 338 | Auxiliary 1 pump control | Modbus 400286; not polled by default | Command | ||
| AO | 339 | System pump output | Modbus 400288 | Command | ||
| AO | 340 | System pump control | Modbus 400289; not polled by default | Command | ||
| AO | 341 | System pump overrun time | Modbus 400290; not polled by default | s | Command | |
| AO | 342 | Pump exercise interval | Modbus 400291; not polled by default | days | Command | |
| AO | 343 | Pump exercise time | Modbus 400292; not polled by default | s | Command | |
| AO | 344 | CH pump start delay | Modbus 400293; not polled by default | s | Command | |
| AO | 345 | Boiler pump start delay | Modbus 400294; not polled by default | s | Command | |
| AO | 346 | System pump start delay | Modbus 400295; not polled by default | s | Command | |
| AO | 347 | Auxiliary 1 pump start delay | Modbus 400296; not polled by default | s | Command | |
| BO | 348 | CH pump options 1 Normal pump demand when aux pump Z is set | Modbus 400297 bit 15; not polled by default | Command | ||
| BO | 349 | CH pump options 1 Normal pump demand when aux pump Y is set | Modbus 400297 bit 14; not polled by default | Command | ||
| BO | 350 | CH pump options 1 Normal pump demand when aux pump X is set | Modbus 400297 bit 13; not polled by default | Command | ||
| BO | 351 | CH pump options 1 Normal pump demand when DHW service is active | Modbus 400297 bit 6; not polled by default | Command | ||
| BO | 352 | CH pump options 1 Normal pump demand when CH service is active | Modbus 400297 bit 5; not polled by default | Command | ||
| BO | 353 | CH pump options 1 Normal pump demand when DHW demand | Modbus 400297 bit 3; not polled by default | Command | ||
| BO | 354 | CH pump options 1 Normal pump demand when CH demand | Modbus 400297 bit 2; not polled by default | Command | ||
| BO | 355 | CH pump options 1 Normal pump demand when local burner demand | Modbus 400297 bit 1; not polled by default | Command | ||
| BO | 356 | CH pump options 1 Local demand inhibited for faults | Modbus 400297 bit 0; not polled by default | Command | ||
| BO | 357 | CH pump options 2 Pump used for Lead Lag | Modbus 400298 bit 15; not polled by default | Command | ||
| BO | 358 | CH pump options 2 Pump used for local demand | Modbus 400298 bit 14; not polled by default | Command | ||
| BO | 359 | CH pump options 2 Force pump off when DHW high limit | Modbus 400298 bit 8; not polled by default | Command | ||
| BO | 360 | CH pump options 2 Force pump off when DHW anti-condensation | Modbus 400298 bit 7; not polled by default | Command | ||
| BO | 361 | CH pump options 2 Force pump off when CH anti-condensation | Modbus 400298 bit 6; not polled by default | Command | ||
| BO | 362 | CH pump options 2 Force pump off when DHW priority is active | Modbus 400298 bit 5; not polled by default | Command | ||
| BO | 363 | CH pump options 2 Force pump on when DHW frost protection | Modbus 400298 bit 4; not polled by default | Command | ||
| BO | 364 | CH pump options 2 Force pump on when CH frost protection | Modbus 400298 bit 3; not polled by default | Command | ||
| BO | 365 | CH pump options 2 Force pump on when Lead Lag slave demand | Modbus 400298 bit 2; not polled by default | Command | ||
| BO | 366 | CH pump options 2 Force pump on when local burner demand | Modbus 400298 bit 1; not polled by default | Command | ||
| BO | 367 | CH pump options 2 Force pump on when Outlet high limit | Modbus 400298 bit 0; not polled by default | Command | ||
| BO | 368 | DHW pump options 1 Normal pump demand when aux pump Z is set | Modbus 400299 bit 15; not polled by default | Command | ||
| BO | 369 | DHW pump options 1 Normal pump demand when aux pump Y is set | Modbus 400299 bit 14; not polled by default | Command | ||
| BO | 370 | DHW pump options 1 Normal pump demand when aux pump X is set | Modbus 400299 bit 13; not polled by default | Command | ||
| BO | 371 | DHW pump options 1 Normal pump demand when DHW is active | Modbus 400299 bit 6; not polled by default | Command | ||
| BO | 372 | DHW pump options 1 Normal pump demand when CH is active | Modbus 400299 bit 5; not polled by default | Command | ||
| BO | 373 | DHW pump options 1 Normal pump demand when DHW demand | Modbus 400299 bit 3; not polled by default | Command | ||
| BO | 374 | DHW pump options 1 Normal pump demand when CH demand | Modbus 400299 bit 2; not polled by default | Command | ||
| BO | 375 | DHW pump options 1 Normal pump demand when local burner demand | Modbus 400299 bit 1; not polled by default | Command | ||
| BO | 376 | DHW pump options 1 Local demand inhibited for faults | Modbus 400299 bit 0; not polled by default | Command | ||
| BO | 377 | DHW pump options 2 Pump used for Lead Lag | Modbus 400300 bit 15; not polled by default | Command | ||
| BO | 378 | DHW pump options 2 Pump used for local demand | Modbus 400300 bit 14; not polled by default | Command | ||
| BO | 379 | DHW pump options 2 Force pump off when DHW high limit | Modbus 400300 bit 8; not polled by default | Command | ||
| BO | 380 | DHW pump options 2 Force pump off when DHW anti-condensation | Modbus 400300 bit 7; not polled by default | Command | ||
| BO | 381 | DHW pump options 2 Force pump off when CH anti-condensation | Modbus 400300 bit 6; not polled by default | Command | ||
| BO | 382 | DHW pump options 2 Force pump off when DHW priority is active | Modbus 400300 bit 5; not polled by default | Command | ||
| BO | 383 | DHW pump options 2 Force pump on when DHW frost protection | Modbus 400300 bit 4; not polled by default | Command | ||
| BO | 384 | DHW pump options 2 Force pump on when CH frost protection | Modbus 400300 bit 3; not polled by default | Command | ||
| BO | 385 | DHW pump options 2 Force pump on when Lead Lag slave demand | Modbus 400300 bit 2; not polled by default | Command | ||
| BO | 386 | DHW pump options 2 Force pump on when local burner demand | Modbus 400300 bit 1; not polled by default | Command | ||
| BO | 387 | DHW pump options 2 Force pump on when Outlet high limit | Modbus 400300 bit 0; not polled by default | Command | ||
| BO | 388 | Boiler pump options 1 Normal pump demand when aux pump Z is set | Modbus 400301 bit 15; not polled by default | Command | ||
| BO | 389 | Boiler pump options 1 Normal pump demand when aux pump Y is set | Modbus 400301 bit 14; not polled by default | Command | ||
| BO | 390 | Boiler pump options 1 Normal pump demand when aux pump X is set | Modbus 400301 bit 13; not polled by default | Command | ||
| BO | 391 | Boiler pump options 1 Normal pump demand when DHW is active | Modbus 400301 bit 6; not polled by default | Command | ||
| BO | 392 | Boiler pump options 1 Normal pump demand when CH is active | Modbus 400301 bit 5; not polled by default | Command | ||
| BO | 393 | Boiler pump options 1 Normal pump demand when DHW demand | Modbus 400301 bit 3; not polled by default | Command | ||
| BO | 394 | Boiler pump options 1 Normal pump demand when CH demand | Modbus 400301 bit 2; not polled by default | Command | ||
| BO | 395 | Boiler pump options 1 Normal pump demand local burner demand | Modbus 400301 bit 1; not polled by default | Command | ||
| BO | 396 | Boiler pump options 1 Local demand inhibited for faults | Modbus 400301 bit 0; not polled by default | Command | ||
| BO | 397 | Boiler pump options 2 Pump used for Lead Lag | Modbus 400302 bit 15; not polled by default | Command | ||
| BO | 398 | Boiler pump options 2 Pump used for local demand | Modbus 400302 bit 14; not polled by default | Command | ||
| BO | 399 | Boiler pump options 2 Force pump off when DHW high limit | Modbus 400302 bit 8; not polled by default | Command | ||
| BO | 400 | Boiler pump options 2 Force pump off when DHW anti-condensation | Modbus 400302 bit 7; not polled by default | Command | ||
| BO | 401 | Boiler pump options 2 Force pump off when CH anti-condensation | Modbus 400302 bit 6; not polled by default | Command | ||
| BO | 402 | Boiler pump options 2 Force pump off HW priority is active | Modbus 400302 bit 5; not polled by default | Command | ||
| BO | 403 | Boiler pump options 2 Force pump on when DHW frost protection | Modbus 400302 bit 4; not polled by default | Command | ||
| BO | 404 | Boiler pump options 2 Force pump on when CH frost protection | Modbus 400302 bit 3; not polled by default | Command | ||
| BO | 405 | Boiler pump options 2 Force pump on when Lead Lag slave demand | Modbus 400302 bit 2; not polled by default | Command | ||
| BO | 406 | Boiler pump options 2 Force pump on when local burner demand | Modbus 400302 bit 1; not polled by default | Command | ||
| BO | 407 | Boiler pump options 2 Force pump on when Outlet high limit | Modbus 400302 bit 0; not polled by default | Command | ||
| BO | 408 | System pump options 1 Normal pump demand when aux pump Z is set | Modbus 400303 bit 15; not polled by default | Command | ||
| BO | 409 | System pump options 1 Normal pump demand when pump Y is set | Modbus 400303 bit 14; not polled by default | Command | ||
| BO | 410 | System pump options 1 Normal pump demand when aux pump X is set | Modbus 400303 bit 13; not polled by default | Command | ||
| BO | 411 | System pump options 1 Normal pump demand DHW service is active | Modbus 400303 bit 6; not polled by default | Command | ||
| BO | 412 | System pump options 1 Normal pump demand CH service is active | Modbus 400303 bit 5; not polled by default | Command | ||
| BO | 413 | System pump options 1 Normal pump demand DHW demand | Modbus 400303 bit 3; not polled by default | Command | ||
| BO | 414 | System pump options 1 Normal pump demand when CH demand | Modbus 400303 bit 2; not polled by default | Command | ||
| BO | 415 | System pump options 1 Normal pump demand local burner demand | Modbus 400303 bit 1; not polled by default | Command | ||
| BO | 416 | System pump options 1 Local demand inhibited for faults | Modbus 400303 bit 0; not polled by default | Command | ||
| BO | 417 | System pump options 2 Pump used for Lead Lag | Modbus 400304 bit 15; not polled by default | Command | ||
| BO | 418 | System pump options 2 Pump used for local demand | Modbus 400304 bit 14; not polled by default | Command | ||
| BO | 419 | System pump options 2 Force pump off when DHW high limit | Modbus 400304 bit 8; not polled by default | Command | ||
| BO | 420 | System pump options 2 Force pump off when DHW anti-condensation | Modbus 400304 bit 7; not polled by default | Command | ||
| BO | 421 | System pump options 2 Force pump off when CH anti-condensation | Modbus 400304 bit 6; not polled by default | Command | ||
| BO | 422 | System pump options 2 Force pump off DHW priority is active | Modbus 400304 bit 5; not polled by default | Command | ||
| BO | 423 | System pump options 2 Force pump on DHW frost protection | Modbus 400304 bit 4; not polled by default | Command | ||
| BO | 424 | System pump options 2 Force pump on when CH frost protection | Modbus 400304 bit 3; not polled by default | Command | ||
| BO | 425 | System pump options 2 Force pump on when Lead Lag slave demand | Modbus 400304 bit 2; not polled by default | Command | ||
| BO | 426 | System pump options 2 Force pump on when local burner demand | Modbus 400304 bit 1; not polled by default | Command | ||
| BO | 427 | System pump options 2 Force pump on when Outlet high limit | Modbus 400304 bit 0; not polled by default | Command | ||
| AO | 428 | Annunciation enable | Modbus 400305; not polled by default | Command | ||
| AO | 429 | Annunciator mode | Modbus 400306; not polled by default | Command | ||
| AO | 430 | Annunciator 1 configuration word 01 | Modbus 400307; not polled by default | Command | ||
| AO | 431 | Annunciator 1 configuration word 02 | Modbus 400308; not polled by default | Command | ||
| AO | 432 | Annunciator 1 configuration word 03 | Modbus 400309; not polled by default | Command | ||
| AO | 433 | Annunciator 1 configuration word 04 | Modbus 400310; not polled by default | Command | ||
| AO | 434 | Annunciator 1 configuration word 05 | Modbus 400311; not polled by default | Command | ||
| AO | 435 | Annunciator 1 configuration word 06 | Modbus 400312; not polled by default | Command | ||
| AO | 436 | Annunciator 1 configuration word 07 | Modbus 400313; not polled by default | Command | ||
| AO | 437 | Annunciator 1 configuration word 08 | Modbus 400314; not polled by default | Command | ||
| AO | 438 | Annunciator 1 configuration word 09 | Modbus 400315; not polled by default | Command | ||
| AO | 439 | Annunciator 1 configuration word 10 | Modbus 400316; not polled by default | Command | ||
| AO | 440 | Annunciator 1 configuration word 11 | Modbus 400317; not polled by default | Command | ||
| AO | 441 | Annunciator 1 configuration word 12 | Modbus 400318; not polled by default | Command | ||
| AO | 442 | Annunciator 1 configuration word 13 | Modbus 400319; not polled by default | Command | ||
| AO | 443 | Annunciator 2 configuration word 01 | Modbus 400320; not polled by default | Command | ||
| AO | 444 | Annunciator 2 configuration word 02 | Modbus 400321; not polled by default | Command | ||
| AO | 445 | Annunciator 2 configuration word 03 | Modbus 400322; not polled by default | Command | ||
| AO | 446 | Annunciator 2 configuration word 04 | Modbus 400323; not polled by default | Command | ||
| AO | 447 | Annunciator 2 configuration word 05 | Modbus 400324; not polled by default | Command | ||
| AO | 448 | Annunciator 2 configuration word 06 | Modbus 400325; not polled by default | Command | ||
| AO | 449 | Annunciator 2 configuration word 07 | Modbus 400326; not polled by default | Command | ||
| AO | 450 | Annunciator 2 configuration word 08 | Modbus 400327; not polled by default | Command | ||
| AO | 451 | Annunciator 2 configuration word 09 | Modbus 400328; not polled by default | Command | ||
| AO | 452 | Annunciator 2 configuration word 10 | Modbus 400329; not polled by default | Command | ||
| AO | 453 | Annunciator 2 configuration word 11 | Modbus 400330; not polled by default | Command | ||
| AO | 454 | Annunciator 2 configuration word 12 | Modbus 400331; not polled by default | Command | ||
| AO | 455 | Annunciator 2 configuration word 13 | Modbus 400332; not polled by default | Command | ||
| AO | 456 | Annunciator 3 configuration word 01 | Modbus 400333; not polled by default | Command | ||
| AO | 457 | Annunciator 3 configuration word 02 | Modbus 400334; not polled by default | Command | ||
| AO | 458 | Annunciator 3 configuration word 03 | Modbus 400335; not polled by default | Command | ||
| AO | 459 | Annunciator 3 configuration word 04 | Modbus 400336; not polled by default | Command | ||
| AO | 460 | Annunciator 3 configuration word 05 | Modbus 400337; not polled by default | Command | ||
| AO | 461 | Annunciator 3 configuration word 06 | Modbus 400338; not polled by default | Command | ||
| AO | 462 | Annunciator 3 configuration word 07 | Modbus 400339; not polled by default | Command | ||
| AO | 463 | Annunciator 3 configuration word 08 | Modbus 400340; not polled by default | Command | ||
| AO | 464 | Annunciator 3 configuration word 09 | Modbus 400341; not polled by default | Command | ||
| AO | 465 | Annunciator 3 configuration word 10 | Modbus 400342; not polled by default | Command | ||
| AO | 466 | Annunciator 3 configuration word 11 | Modbus 400343; not polled by default | Command | ||
| AO | 467 | Annunciator 3 configuration word 12 | Modbus 400344; not polled by default | Command | ||
| AO | 468 | Annunciator 3 configuration word 13 | Modbus 400345; not polled by default | Command | ||
| AO | 469 | Annunciator 4 configuration word 01 | Modbus 400346; not polled by default | Command | ||
| AO | 470 | Annunciator 4 configuration word 02 | Modbus 400347; not polled by default | Command | ||
| AO | 471 | Annunciator 4 configuration word 03 | Modbus 400348; not polled by default | Command | ||
| AO | 472 | Annunciator 4 configuration word 04 | Modbus 400349; not polled by default | Command | ||
| AO | 473 | Annunciator 4 configuration word 05 | Modbus 400350; not polled by default | Command | ||
| AO | 474 | Annunciator 4 configuration word 06 | Modbus 400351; not polled by default | Command | ||
| AO | 475 | Annunciator 4 configuration word 07 | Modbus 400352; not polled by default | Command | ||
| AO | 476 | Annunciator 4 configuration word 08 | Modbus 400353; not polled by default | Command | ||
| AO | 477 | Annunciator 4 configuration word 09 | Modbus 400354; not polled by default | Command | ||
| AO | 478 | Annunciator 4 configuration word 10 | Modbus 400355; not polled by default | Command | ||
| AO | 479 | Annunciator 4 configuration word 11 | Modbus 400356; not polled by default | Command | ||
| AO | 480 | Annunciator 4 configuration word 12 | Modbus 400357; not polled by default | Command | ||
| AO | 481 | Annunciator 4 configuration word 13 | Modbus 400358; not polled by default | Command | ||
| AO | 482 | Annunciator 5 configuration word 01 | Modbus 400359; not polled by default | Command | ||
| AO | 483 | Annunciator 5 configuration word 02 | Modbus 400360; not polled by default | Command | ||
| AO | 484 | Annunciator 5 configuration word 03 | Modbus 400361; not polled by default | Command | ||
| AO | 485 | Annunciator 5 configuration word 04 | Modbus 400362; not polled by default | Command | ||
| AO | 486 | Annunciator 5 configuration word 05 | Modbus 400363; not polled by default | Command | ||
| AO | 487 | Annunciator 5 configuration word 06 | Modbus 400364; not polled by default | Command | ||
| AO | 488 | Annunciator 5 configuration word 07 | Modbus 400365; not polled by default | Command | ||
| AO | 489 | Annunciator 5 configuration word 08 | Modbus 400366; not polled by default | Command | ||
| AO | 490 | Annunciator 5 configuration word 09 | Modbus 400367; not polled by default | Command | ||
| AO | 491 | Annunciator 5 configuration word 10 | Modbus 400368; not polled by default | Command | ||
| AO | 492 | Annunciator 5 configuration word 11 | Modbus 400369; not polled by default | Command | ||
| AO | 493 | Annunciator 5 configuration word 12 | Modbus 400370; not polled by default | Command | ||
| AO | 494 | Annunciator 5 configuration word 13 | Modbus 400371; not polled by default | Command | ||
| AO | 495 | Annunciator 6 configuration word 01 | Modbus 400372; not polled by default | Command | ||
| AO | 496 | Annunciator 6 configuration word 02 | Modbus 400373; not polled by default | Command | ||
| AO | 497 | Annunciator 6 configuration word 03 | Modbus 400374; not polled by default | Command | ||
| AO | 498 | Annunciator 6 configuration word 04 | Modbus 400375; not polled by default | Command | ||
| AO | 499 | Annunciator 6 configuration word 05 | Modbus 400376; not polled by default | Command | ||
| AO | 500 | Annunciator 6 configuration word 06 | Modbus 400377; not polled by default | Command | ||
| AO | 501 | Annunciator 6 configuration word 07 | Modbus 400378; not polled by default | Command | ||
| AO | 502 | Annunciator 6 configuration word 08 | Modbus 400379; not polled by default | Command | ||
| AO | 503 | Annunciator 6 configuration word 09 | Modbus 400380; not polled by default | Command | ||
| AO | 504 | Annunciator 6 configuration word 10 | Modbus 400381; not polled by default | Command | ||
| AO | 505 | Annunciator 6 configuration word 11 | Modbus 400382; not polled by default | Command | ||
| AO | 506 | Annunciator 6 configuration word 12 | Modbus 400383; not polled by default | Command | ||
| AO | 507 | Annunciator 6 configuration word 13 | Modbus 400384; not polled by default | Command | ||
| AO | 508 | Annunciator 7 configuration word 01 | Modbus 400385; not polled by default | Command | ||
| AO | 509 | Annunciator 7 configuration word 02 | Modbus 400386; not polled by default | Command | ||
| AO | 510 | Annunciator 7 configuration word 03 | Modbus 400387; not polled by default | Command | ||
| AO | 511 | Annunciator 7 configuration word 04 | Modbus 400388; not polled by default | Command | ||
| AO | 512 | Annunciator 7 configuration word 05 | Modbus 400389; not polled by default | Command | ||
| AO | 513 | Annunciator 7 configuration word 06 | Modbus 400390; not polled by default | Command | ||
| AO | 514 | Annunciator 7 configuration word 07 | Modbus 400391; not polled by default | Command | ||
| AO | 515 | Annunciator 7 configuration word 08 | Modbus 400392; not polled by default | Command | ||
| AO | 516 | Annunciator 7 configuration word 09 | Modbus 400393; not polled by default | Command | ||
| AO | 517 | Annunciator 7 configuration word 10 | Modbus 400394; not polled by default | Command | ||
| AO | 518 | Annunciator 7 configuration word 11 | Modbus 400395; not polled by default | Command | ||
| AO | 519 | Annunciator 7 configuration word 12 | Modbus 400396; not polled by default | Command | ||
| AO | 520 | Annunciator 7 configuration word 13 | Modbus 400397; not polled by default | Command | ||
| AO | 521 | Annunciator 8 configuration word 01 | Modbus 400398; not polled by default | Command | ||
| AO | 522 | Annunciator 8 configuration word 02 | Modbus 400399; not polled by default | Command | ||
| AO | 523 | Annunciator 8 configuration word 03 | Modbus 400400; not polled by default | Command | ||
| AO | 524 | Annunciator 8 configuration word 04 | Modbus 400401; not polled by default | Command | ||
| AO | 525 | Annunciator 8 configuration word 05 | Modbus 400402; not polled by default | Command | ||
| AO | 526 | Annunciator 8 configuration word 06 | Modbus 400403; not polled by default | Command | ||
| AO | 527 | Annunciator 8 configuration word 07 | Modbus 400404; not polled by default | Command | ||
| AO | 528 | Annunciator 8 configuration word 08 | Modbus 400405; not polled by default | Command | ||
| AO | 529 | Annunciator 8 configuration word 09 | Modbus 400406; not polled by default | Command | ||
| AO | 530 | Annunciator 8 configuration word 10 | Modbus 400407; not polled by default | Command | ||
| AO | 531 | Annunciator 8 configuration word 11 | Modbus 400408; not polled by default | Command | ||
| AO | 532 | Annunciator 8 configuration word 12 | Modbus 400409; not polled by default | Command | ||
| AO | 533 | Annunciator 8 configuration word 13 | Modbus 400410; not polled by default | Command | ||
| AO | 534 | PII configuration word 01 | Modbus 400411; not polled by default | Command | ||
| AO | 535 | PII configuration word 02 | Modbus 400412; not polled by default | Command | ||
| AO | 536 | PII configuration word 03 | Modbus 400413; not polled by default | Command | ||
| AO | 537 | PII configuration word 04 | Modbus 400414; not polled by default | Command | ||
| AO | 538 | PII configuration word 05 | Modbus 400415; not polled by default | Command | ||
| AO | 539 | PII configuration word 06 | Modbus 400416; not polled by default | Command | ||
| AO | 540 | PII configuration word 07 | Modbus 400417; not polled by default | Command | ||
| AO | 541 | PII configuration word 08 | Modbus 400418; not polled by default | Command | ||
| AO | 542 | PII configuration word 09 | Modbus 400419; not polled by default | Command | ||
| AO | 543 | PII configuration word 10 | Modbus 400420; not polled by default | Command | ||
| AO | 544 | PII configuration word 11 | Modbus 400421; not polled by default | Command | ||
| AO | 545 | PII configuration word 12 | Modbus 400422; not polled by default | Command | ||
| AO | 546 | LCI configuration word 01 | Modbus 400423; not polled by default | Command | ||
| AO | 547 | LCI configuration word 02 | Modbus 400424; not polled by default | Command | ||
| AO | 548 | LCI configuration word 03 | Modbus 400425; not polled by default | Command | ||
| AO | 549 | LCI configuration word 04 | Modbus 400426; not polled by default | Command | ||
| AO | 550 | LCI configuration word 05 | Modbus 400427; not polled by default | Command | ||
| AO | 551 | LCI configuration word 06 | Modbus 400428; not polled by default | Command | ||
| AO | 552 | LCI configuration word 07 | Modbus 400429; not polled by default | Command | ||
| AO | 553 | LCI configuration word 08 | Modbus 400430; not polled by default | Command | ||
| AO | 554 | LCI configuration word 09 | Modbus 400431; not polled by default | Command | ||
| AO | 555 | LCI configuration word 10 | Modbus 400432; not polled by default | Command | ||
| AO | 556 | LCI configuration word 11 | Modbus 400433; not polled by default | Command | ||
| AO | 557 | LCI configuration word 12 | Modbus 400434; not polled by default | Command | ||
| AO | 558 | ILK configuration word 01 | Modbus 400435; not polled by default | Command | ||
| AO | 559 | ILK configuration word 02 | Modbus 400436; not polled by default | Command | ||
| AO | 560 | ILK configuration word 03 | Modbus 400437; not polled by default | Command | ||
| AO | 561 | ILK configuration word 04 | Modbus 400438; not polled by default | Command | ||
| AO | 562 | ILK configuration word 05 | Modbus 400439; not polled by default | Command | ||
| AO | 563 | ILK configuration word 06 | Modbus 400440; not polled by default | Command | ||
| AO | 564 | ILK configuration word 07 | Modbus 400441; not polled by default | Command | ||
| AO | 565 | ILK configuration word 08 | Modbus 400442; not polled by default | Command | ||
| AO | 566 | ILK configuration word 09 | Modbus 400443; not polled by default | Command | ||
| AO | 567 | ILK configuration word 10 | Modbus 400444; not polled by default | Command | ||
| AO | 568 | ILK configuration word 11 | Modbus 400445; not polled by default | Command | ||
| AO | 569 | ILK configuration word 12 | Modbus 400446; not polled by default | Command | ||
| AO | 570 | DHW enable | Modbus 400449; not polled by default | Command | ||
| AO | 571 | DHW demand switch | Modbus 400450; not polled by default | Command | ||
| AO | 572 | DHW priority vs CH | Modbus 400451; not polled by default | Command | ||
| AO | 573 | DHW priority vs LL | Modbus 400452; not polled by default | Command | ||
| AO | 574 | DHW priority time | Modbus 400453; not polled by default | Command | ||
| AO | 575 | DHW setpoint | Modbus 400454; not polled by default | °C | Command | |
| AO | 576 | DHW time of day setpoint | Modbus 400455; not polled by default | °C | Command | |
| AO | 577 | DHW on hysteresis | Modbus 400456; not polled by default | °C | Command | |
| AO | 578 | DHW off hysteresis | Modbus 400457; not polled by default | °C | Command | |
| AO | 579 | DHW P-gain | Modbus 400458; not polled by default | Command | ||
| AO | 580 | DHW I-gain | Modbus 400459; not polled by default | Command | ||
| AO | 581 | DHW D-gain | Modbus 400460; not polled by default | Command | ||
| AO | 582 | DHW hysteresis step time | Modbus 400461; not polled by default | s | Command | |
| AO | 583 | DHW modulation sensor | Modbus 400462; not polled by default | Command | ||
| AO | 584 | DHW priority source | Modbus 400464; not polled by default | Command | ||
| AO | 585 | Outlet high limit setpoint | Modbus 400465; not polled by default | °C | Command | |
| AO | 586 | Outlet high limit response | Modbus 400466; not polled by default | Command | ||
| AO | 587 | Stack limit enable | Modbus 400467; not polled by default | Command | ||
| AO | 588 | Stack limit setpoint | Modbus 400468; not polled by default | °C | Command | |
| AO | 589 | Stack limit response | Modbus 400469; not polled by default | Command | ||
| AO | 590 | Stack limit delay | Modbus 400470; not polled by default | s | Command | |
| AO | 591 | Delta-T inlet/outlet enable | Modbus 400471; not polled by default | Command | ||
| AO | 592 | Delta-T inlet/outlet degrees | Modbus 400472; not polled by default | °C | Command | |
| AO | 593 | Delta-T response | Modbus 400473; not polled by default | Command | ||
| AO | 594 | Delta-T delay | Modbus 400474; not polled by default | s | Command | |
| AO | 595 | DHW high limit enable | Modbus 400475; not polled by default | Command | ||
| AO | 596 | DHW high limit setpoint | Modbus 400476; not polled by default | °C | Command | |
| AO | 597 | DHW high limit response | Modbus 400477; not polled by default | Command | ||
| AO | 598 | CH slow start enable | Modbus 400478; not polled by default | Command | ||
| AO | 599 | DHW slow start enable | Modbus 400479; not polled by default | Command | ||
| AO | 600 | Slow start ramp | Modbus 400480; not polled by default | Command | ||
| AO | 601 | Slow start setpoint | Modbus 400481; not polled by default | °C | Command | |
| AO | 602 | Outlet T-rise enable | Modbus 400482; not polled by default | Command | ||
| AO | 603 | Outlet T-rise degrees | Modbus 400483; not polled by default | Command | ||
| AO | 604 | Outlet T-rise delay | Modbus 400484; not polled by default | s | Command | |
| AO | 605 | Outlet high limit enable | Modbus 400485; not polled by default | Command | ||
| AO | 606 | Delta-T retry limit | Modbus 400486; not polled by default | Command | ||
| AO | 607 | Delta-T rate limit enable | Modbus 400487; not polled by default | Command | ||
| AO | 608 | Delta-T inverse limit time | Modbus 400488; not polled by default | s | Command | |
| AO | 609 | Delta-T inverse limit response | Modbus 400489; not polled by default | Command | ||
| AO | 610 | Delta-T exchanger/outlet enable | Modbus 400490; not polled by default | Command | ||
| AO | 611 | Delta-T exchanger/outlet degrees | Modbus 400491; not polled by default | °C | Command | |
| AO | 612 | Exchanger T-rise enable | Modbus 400492; not polled by default | Command | ||
| AO | 613 | T-rise response | Modbus 400493; not polled by default | Command | ||
| AO | 614 | T-rise retry limit | Modbus 400494; not polled by default | Command | ||
| AO | 615 | Delta-T inlet/exchanger enable | Modbus 400495; not polled by default | Command | ||
| AO | 616 | Delta-T inlet/exchanger degrees | Modbus 400496; not polled by default | °C | Command | |
| AO | 617 | CH anticondensation enable | Modbus 400497; not polled by default | Command | ||
| AO | 618 | CH anticondensation setpoint | Modbus 400498; not polled by default | °C | Command | |
| AO | 619 | CH anticondensation pump force off | Modbus 400499; not polled by default | Command | ||
| AO | 620 | DHW anticondensation enable | Modbus 400500; not polled by default | Command | ||
| AO | 621 | DHW anticondensation setpoint | Modbus 400501; not polled by default | °C | Command | |
| AO | 622 | DHW anticondensation pump force off | Modbus 400502; not polled by default | Command | ||
| BO | 623 | Anticondensation priority Outlet high limit | Modbus 400503 bit 4; not polled by default | Command | ||
| BO | 624 | Anticondensation priority Forced rate | Modbus 400503 bit 3; not polled by default | Command | ||
| BO | 625 | Anticondensation priority Slow start | Modbus 400503 bit 2; not polled by default | Command | ||
| BO | 626 | Anticondensation priority Delta-T limit | Modbus 400503 bit 1; not polled by default | Command | ||
| BO | 627 | Anticondensation priority Stack limit | Modbus 400503 bit 0; not polled by default | Command | ||
| AO | 628 | Frost protection anticondensation enable | Modbus 400504; not polled by default | Command | ||
| AO | 629 | DHW storage enable | Modbus 400505; not polled by default | Command | ||
| AO | 630 | DHW storage time | Modbus 400506; not polled by default | s | Command | |
| AO | 631 | DHW storage setpoint | Modbus 400507; not polled by default | Command | ||
| AO | 632 | DHW storage on hysteresis | Modbus 400508; not polled by default | Command | ||
| AO | 633 | DHW storage off hysteresis | Modbus 400509; not polled by default | Command | ||
| AO | 634 | DHW priority method | Modbus 400510; not polled by default | Command | ||
| AO | 635 | CH ODR maximum outdoor temperature | Modbus 400513; not polled by default | °C | Command | |
| AO | 636 | CH ODR minimum outdoor temperature | Modbus 400514; not polled by default | °C | Command | |
| AO | 637 | CH ODR low water temperature | Modbus 400515; not polled by default | °C | Command | |
| AO | 638 | CH ODR boost time | Modbus 400516; not polled by default | s | Command | |
| AO | 639 | CH ODR maximum off point | Modbus 400517; not polled by default | °C | Command | |
| AO | 640 | Lead Lag CH ODR maximum outdoor temperature | Modbus 400518; not polled by default | °C | Command | |
| AO | 641 | Lead Lag CH ODR minimum outdoor temperature | Modbus 400519; not polled by default | °C | Command | |
| AO | 642 | Lead Lag CH ODR low water temperature | Modbus 400520; not polled by default | °C | Command | |
| AO | 643 | Lead Lag CH ODR boost time | Modbus 400521; not polled by default | s | Command | |
| AO | 644 | Lead Lag CH ODR maximum off point | Modbus 400522; not polled by default | °C | Command | |
| AO | 645 | CH ODR boost step | Modbus 400523; not polled by default | °C | Command | |
| AO | 646 | CH ODR boost recovery step time | Modbus 400524; not polled by default | s | Command | |
| AO | 647 | Lead Lag CH ODR boost step | Modbus 400525; not polled by default | °C | Command | |
| AO | 648 | Lead Lag CH ODR boost recovery step time | Modbus 400526; not polled by default | s | Command | |
| AO | 649 | Minimum boiler water temperature | Modbus 400527; not polled by default | °C | Command | |
| AO | 650 | Lead Lag CH ODR minimum water temperature | Modbus 400528; not polled by default | °C | Command | |
| AO | 651 | CH frost protection enable | Modbus 400529; not polled by default | Command | ||
| AO | 652 | DHW frost protection enable R/W | Modbus 400530; not polled by default | Command | ||
| AO | 653 | Outdoor frost protection setpoint | Modbus 400531; not polled by default | °C | Command | |
| AO | 654 | Lead Lag frost protection enable | Modbus 400533; not polled by default | Command | ||
| AO | 655 | Lead Lag frost protection rate | Modbus 400534; not polled by default | % | Command | |
| AO | 656 | IAS open modulation enable | Modbus 400537; not polled by default | Command | ||
| AO | 657 | IAS open rate differential | Modbus 400538; not polled by default | Command | ||
| AO | 658 | IAS open modulation step rate | Modbus 400539; not polled by default | Command | ||
| AO | 659 | IAS open modulation step time | Modbus 400540; not polled by default | s | Command | |
| AO | 660 | IAS closed response | Modbus 400541; not polled by default | Command | ||
| AO | 661 | CH minimum pressure | Modbus 400542; not polled by default | psi | Command | |
| AO | 662 | CH time of day pressure setpoint | Modbus 400543; not polled by default | psi | Command | |
| AO | 663 | Analog input hysteresis | Modbus 400544; not polled by default | mA | Command | |
| AO | 664 | Lead Lag slave enable | Modbus 400545; not polled by default | Command | ||
| AO | 665 | Lead Lag master enable | Modbus 400546; not polled by default | Command | ||
| AO | 666 | Lead Lag setpoint | Modbus 400547; not polled by default | °C | Command | |
| AO | 667 | Lead Lag time of day setpoint | Modbus 400548; not polled by default | °C | Command | |
| AO | 668 | Lead Lag outdoor reset enable | Modbus 400549; not polled by default | Command | ||
| AO | 669 | Lead Lag on hysteresis | Modbus 400550; not polled by default | °C | Command | |
| AO | 670 | Lead Lag off hysteresis | Modbus 400551; not polled by default | °C | Command | |
| AO | 671 | Lead Lag hysteresis step time | Modbus 400552; not polled by default | s | Command | |
| AO | 672 | Lead Lag P-gain | Modbus 400553; not polled by default | Command | ||
| AO | 673 | Lead Lag I-gain | Modbus 400554; not polled by default | Command | ||
| AO | 674 | Lead Lag D-gain | Modbus 400555; not polled by default | Command | ||
| AO | 675 | Lead Lag operation switch | Modbus 400556; not polled by default | Command | ||
| AO | 676 | Lead Lag CH demand switch | Modbus 400557; not polled by default | Command | ||
| AO | 677 | Lead Lag CH setpoint source | Modbus 400558; not polled by default | Command | ||
| AO | 678 | Lead Lag modulation sensor | Modbus 400559; not polled by default | Command | ||
| AO | 679 | Lead Lag modulation backup sensor | Modbus 400560; not polled by default | Command | ||
| AO | 680 | Lead Lag CH 4 mA water temperature | Modbus 400561; not polled by default | °C | Command | |
| AO | 681 | Lead Lag CH 20 mA water temperature | Modbus 400562; not polled by default | °C | Command | |
| AO | 682 | Lead Lag CH Modbus setpoint | Modbus 400563; not polled by default | °C | Command | |
| AO | 683 | Lead Lag CH Modbus STAT | Modbus 400564; not polled by default | Command | ||
| AO | 684 | Slave mode | Modbus 400565; not polled by default | Command | ||
| BO | 685 | Slave command Slave demand request | Modbus 400566 bit 15; not polled by default | Command | ||
| BO | 686 | Slave command Slave suspend startup | Modbus 400566 bit 14; not polled by default | Command | ||
| BO | 687 | Slave command Slave run fan request | Modbus 400566 bit 13; not polled by default | Command | ||
| BO | 688 | Slave command Turn on auxiliary pump X | Modbus 400566 bit 12; not polled by default | Command | ||
| BO | 689 | Slave command Turn on auxiliary pump Y | Modbus 400566 bit 11; not polled by default | Command | ||
| BO | 690 | Slave command Turn on auxiliary pump Z | Modbus 400566 bit 10; not polled by default | Command | ||
| BO | 691 | Slave command Commanded rate is binary fraction % | Modbus 400566 bit 8; not polled by default | Command | ||
| BO | 692 | Slave command Commanded rate bit 7 | Modbus 400566 bit 7; not polled by default | Command | ||
| BO | 693 | Slave command Commanded rate bit 6 | Modbus 400566 bit 6; not polled by default | Command | ||
| BO | 694 | Slave command Commanded rate bit 5 | Modbus 400566 bit 5; not polled by default | Command | ||
| BO | 695 | Slave command Commanded rate bit 4 | Modbus 400566 bit 4; not polled by default | Command | ||
| BO | 696 | Slave command Commanded rate bit 3 | Modbus 400566 bit 3; not polled by default | Command | ||
| BO | 697 | Slave command Commanded rate bit 2 | Modbus 400566 bit 2; not polled by default | Command | ||
| BO | 698 | Slave command Commanded rate bit 1 | Modbus 400566 bit 1; not polled by default | Command | ||
| BO | 699 | Slave command Commanded rate bit 0 | Modbus 400566 bit 0; not polled by default | Command | ||
| AO | 700 | Base load rate | Modbus 400567; not polled by default | Command | ||
| AO | 701 | Fan during off cycle rate | Modbus 400568; not polled by default | Command | ||
| AO | 702 | Slave sequence order | Modbus 400569; not polled by default | Command | ||
| AO | 703 | Lead Lag Modbus port | Modbus 400570; not polled by default | Command | ||
| AO | 704 | Slave demand to firing delay R/W | Modbus 400571; not polled by default | s | Command | |
| AO | 705 | Slave capacity | Modbus 400572; not polled by default | Command | ||
| AO | 706 | Base load common rate | Modbus 400573; not polled by default | Command | ||
| AO | 707 | Rate allocation method | Modbus 400574; not polled by default | Command | ||
| AO | 708 | Lead allocation method | Modbus 400575; not polled by default | Command | ||
| AO | 709 | Lag allocation method | Modbus 400576; not polled by default | Command | ||
| AO | 710 | CH Modbus STAT | Modbus 400578; not polled by default | Command | ||
| AO | 711 | CH setpoint source | Modbus 400579; not polled by default | Command | ||
| AO | 712 | CH Modbus setpoint | Modbus 400580; not polled by default | °C | Command | |
| AO | 713 | CH modulation rate source | Modbus 400581; not polled by default | Command | ||
| AO | 714 | CH Modbus rate | Modbus 400582; not polled by default | Command | ||
| AO | 715 | CH priority vs. Lead Lag | Modbus 400583; not polled by default | Command | ||
| AO | 716 | CH 4mA water temperature | Modbus 400584; not polled by default | °C | Command | |
| AO | 717 | CH 20mA water temperature | Modbus 400585; not polled by default | °C | Command | |
| AO | 718 | CH 4mA steam pressure | Modbus 400586; not polled by default | psi | Command | |
| AO | 719 | CH 20mA steam pressure | Modbus 400587; not polled by default | psi | Command | |
| AO | 720 | Heat exchanger high limit enable | Modbus 400593; not polled by default | Command | ||
| AO | 721 | Heat exchanger high limit setpoint | Modbus 400594; not polled by default | °C | Command | |
| AO | 722 | Heat exchanger high limit response | Modbus 400595; not polled by default | Command | ||
| AO | 723 | Heat exchanger high limit delay | Modbus 400596; not polled by default | s | Command | |
| AO | 724 | Heat exchanger retry limit | Modbus 400597; not polled by default | Command | ||
| AO | 725 | S1 (J8-4) connector type (inlet sensor) | Modbus 400609; not polled by default | Command | ||
| AO | 726 | S2 (J8-6) connector type(4-20mA remote control input) | Modbus 400610; not polled by default | Command | ||
| AO | 727 | S3S4 (J8-8 10) connector type | Modbus 400611; not polled by default | Command | ||
| AO | 728 | S5 (J8-11) connector type | Modbus 400612; not polled by default | Command | ||
| AO | 729 | S6S7 (J9-1 3) connector type | Modbus 400613; not polled by default | Command | ||
| AO | 730 | S8S9 (J9-4 6) connector type | Modbus 400614; not polled by default | Command | ||
| AO | 731 | S10 (J10-7) connector type | Modbus 400615; not polled by default | Command | ||
| AO | 732 | Installer passcode | Modbus 400625; not polled by default | Command | ||
| AO | 733 | OEM passcode | Modbus 400626; not polled by default | Command | ||
| AO | 734 | Outdoor temperature source | Modbus 400627; not polled by default | Command | ||
| AO | 735 | Warm weather shutdown enable | Modbus 400628; not polled by default | Command | ||
| AO | 736 | Warm weather shutdown setpoint | Modbus 400629; not polled by default | °C | Command | |
| AO | 737 | Use STAT with EnviraCOM remote stat | Modbus 400630; not polled by default | Command | ||
| AO | 738 | Plate preheat delay after tap | Modbus 400689; not polled by default | s | Command | |
| AO | 739 | Plate preheat setpoint | Modbus 400690; not polled by default | °C | Command | |
| AO | 740 | Plate preheat on recognition time | Modbus 400691; not polled by default | s | Command | |
| AO | 741 | Plate preheat on hysteresis | Modbus 400692; not polled by default | °C | Command | |
| AO | 742 | Plate preheat off hysteresis | Modbus 400693; not polled by default | °C | Command | |
| AO | 743 | Plate preheat minimum on time | Modbus 400694; not polled by default | s | Command | |
| AO | 744 | Tap detect degrees | Modbus 400695; not polled by default | °C | Command | |
| AO | 745 | Tap detect on hysteresis | Modbus 400696; not polled by default | °C | Command | |
| AO | 746 | Tap detect on recognition time | Modbus 400697; not polled by default | s | Command | |
| AO | 747 | Tap stop DHW-Inlet degrees | Modbus 400698; not polled by default | °C | Command | |
| AO | 748 | Tap stop Outlet-Inlet degrees | Modbus 400699; not polled by default | °C | Command | |
| AO | 749 | Tap detect minimum on time | Modbus 400700; not polled by default | s | Command | |
| AO | 750 | Lead Lag DHW demand switch | Modbus 400705; not polled by default | Command | ||
| AO | 751 | Lead Lag DHW setpoint | Modbus 400706; not polled by default | °C | Command | |
| AO | 752 | Lead Lag DHW priority vs. CH | Modbus 400707; not polled by default | Command | ||
| AO | 753 | Warm weather shutdown enable | Modbus 400712; not polled by default | Command | ||
| AO | 754 | Warm weather shutdown setpoint | Modbus 400713; not polled by default | °C | Command | |
| AO | 755 | Slave dropout/return compensation | Modbus 400714; not polled by default | Command | ||
| AO | 756 | Add stage method | Modbus 400715; not polled by default | Command | ||
| AO | 757 | Add stage detection time | Modbus 400717; not polled by default | s | Command | |
| AO | 758 | Add stage error threshold | Modbus 400719; not polled by default | °C | Command | |
| AO | 759 | Add stage rate offset | Modbus 400720; not polled by default | % | Command | |
| AO | 760 | Add stage error gain | Modbus 400721; not polled by default | Command | ||
| AO | 761 | Add stage rate gain | Modbus 400722; not polled by default | Command | ||
| AO | 762 | Add stage inter-stage delay | Modbus 400723; not polled by default | s | Command | |
| AO | 763 | Drop stage method | Modbus 400724; not polled by default | Command | ||
| AO | 764 | Drop stage detection time | Modbus 400726; not polled by default | s | Command | |
| AO | 765 | Drop stage error threshold | Modbus 400728; not polled by default | °C | Command | |
| AO | 766 | Drop stage rate offset | Modbus 400729; not polled by default | % | Command | |
| AO | 767 | Drop stage error gain | Modbus 400730; not polled by default | Command | ||
| AO | 768 | Drop stage rate gain | Modbus 400731; not polled by default | Command | ||
| AO | 769 | Drop stage inter-stage delay | Modbus 400732; not polled by default | s | Command | |
| AO | 770 | Lead rotation time | Modbus 400734; not polled by default | s | Command | |
| AO | 771 | Force lead rotation time | Modbus 400735; not polled by default | s | Command | |
| AO | 772 | Auxiliary 1 pump overrun time | Modbus 400753; not polled by default | s | Command | |
| BO | 773 | Aux 1 pump option 1 Normal demand when aux pump Z is set | Modbus 400754 bit 15; not polled by default | Command | ||
| BO | 774 | Aux 1 pump option 1 Normal demand when aux pump Y is set | Modbus 400754 bit 14; not polled by default | Command | ||
| BO | 775 | Aux 1 pump option 1 Normal demand when aux pump X is set | Modbus 400754 bit 13; not polled by default | Command | ||
| BO | 776 | Aux 1 pump option 1 Normal demand when DHW service is active | Modbus 400754 bit 6; not polled by default | Command | ||
| BO | 777 | Aux 1 pump option 1 Normal demand when CH service is active | Modbus 400754 bit 5; not polled by default | Command | ||
| BO | 778 | Aux 1 pump option 1 Normal demand when DHW demand | Modbus 400754 bit 3; not polled by default | Command | ||
| BO | 779 | Aux 1 pump option 1 Normal demand when CH demand | Modbus 400754 bit 2; not polled by default | Command | ||
| BO | 780 | Aux 1 pump option 1 Normal demand when local burner demand | Modbus 400754 bit 1; not polled by default | Command | ||
| BO | 781 | Aux 1 pump option 1 Local demand inhibited for faults | Modbus 400754 bit 0; not polled by default | Command | ||
| BO | 782 | Aux 1 pump options 2 Pump used for Lead Lag | Modbus 400755 bit 15; not polled by default | Command | ||
| BO | 783 | Aux 1 pump options 2 Pump used for local demand | Modbus 400755 bit 14; not polled by default | Command | ||
| BO | 784 | Aux 1 pump options 2 Force pump off when DHW high limit | Modbus 400755 bit 8; not polled by default | Command | ||
| BO | 785 | Aux 1 pump options 2 Force pump off when DHW anti-condensation | Modbus 400755 bit 7; not polled by default | Command | ||
| BO | 786 | Aux 1 pump options 2 Force pump off when CH anti-condensation | Modbus 400755 bit 6; not polled by default | Command | ||
| BO | 787 | Aux 1 pump options 2 Force pump off when DHW priority is active | Modbus 400755 bit 5; not polled by default | Command | ||
| BO | 788 | Aux 1 pump options 2 Force pump on when DHW frost protection | Modbus 400755 bit 4; not polled by default | Command | ||
| BO | 789 | Aux 1 pump options 2 Force pump on when CH frost protection | Modbus 400755 bit 3; not polled by default | Command | ||
| BO | 790 | Aux 1 pump options 2 Force pump on when Lead Lag slave demand | Modbus 400755 bit 2; not polled by default | Command | ||
| BO | 791 | Aux 1 pump options 2 Force pump on when local burner demand | Modbus 400755 bit 1; not polled by default | Command | ||
| BO | 792 | Aux 1 pump options 2 Force pump on when Outlet high limit | Modbus 400755 bit 0; not polled by default | Command | ||
| AO | 793 | Auxiliary 2 pump output | Modbus 400756; not polled by default | Command | ||
| AO | 794 | Auxiliary 2 pump control | Modbus 400757; not polled by default | Command | ||
| AO | 795 | Auxiliary 2 pump start delay | Modbus 400758; not polled by default | s | Command | |
| AO | 796 | Auxiliary 2 pump overrun time | Modbus 400759; not polled by default | s | Command | |
| BO | 797 | Aux 2 pump option 1 Normal demand when aux pump Z is set | Modbus 400760 bit 15; not polled by default | Command | ||
| BO | 798 | Aux 2 pump option 1 Normal demand when aux pump Y is set | Modbus 400760 bit 14; not polled by default | Command | ||
| BO | 799 | Aux 2 pump option 1 Normal demand when aux pump X is set | Modbus 400760 bit 13; not polled by default | Command | ||
| BO | 800 | Aux 2 pump option 1 Normal demand when DHW service is active | Modbus 400760 bit 6; not polled by default | Command | ||
| BO | 801 | Aux 2 pump option 1 Normal demand when CH service is active | Modbus 400760 bit 5; not polled by default | Command | ||
| BO | 802 | Aux 2 pump option 1 Normal demand when DHW demand | Modbus 400760 bit 3; not polled by default | Command | ||
| BO | 803 | Aux 2 pump option 1 Normal demand when CH demand | Modbus 400760 bit 2; not polled by default | Command | ||
| BO | 804 | Aux 2 pump option 1 Normal demand when local burner demand | Modbus 400760 bit 1; not polled by default | Command | ||
| BO | 805 | Aux 2 pump option 1 Local demand inhibited for faults | Modbus 400760 bit 0; not polled by default | Command | ||
| BO | 806 | Aux 2 pump option 1 Pump used for Lead Lag | Modbus 400761 bit 15; not polled by default | Command | ||
| BO | 807 | Aux 2 pump option 1 Pump used for local demand | Modbus 400761 bit 14; not polled by default | Command | ||
| BO | 808 | Aux 2 pump option 1 Force pump off when DHW high limit | Modbus 400761 bit 8; not polled by default | Command | ||
| BO | 809 | Aux 2 pump option 1 Force pump off when DHW anti-condensation | Modbus 400761 bit 7; not polled by default | Command | ||
| BO | 810 | Aux 2 pump option 1 Force pump off when CH anti-condensation | Modbus 400761 bit 6; not polled by default | Command | ||
| BO | 811 | Aux 2 pump option 1 Force pump off when DHW priority is active | Modbus 400761 bit 5; not polled by default | Command | ||
| BO | 812 | Aux 2 pump option 1 Force pump on when DHW frost protection | Modbus 400761 bit 4; not polled by default | Command | ||
| BO | 813 | Aux 2 pump option 1 Force pump on when CH frost protection | Modbus 400761 bit 3; not polled by default | Command | ||
| BO | 814 | Aux 2 pump option 1 Force pump on when Lead Lag slave demand | Modbus 400761 bit 2; not polled by default | Command | ||
| BO | 815 | Aux 2 pump option 1 Force pump on when local burner demand | Modbus 400761 bit 1; not polled by default | Command | ||
| BO | 816 | Aux 2 pump option 1 Force pump on when Outlet high limit | Modbus 400761 bit 0; not polled by default | Command |
No points match these filters.
Object ID lookup: Contemporary Controls BASgatewayLX Cleaver-Brooks Falcon point IDs by name
BI1Status Change Alert logBI2Status Change Lockout historyBI3Status Change Lead Lag statusBI4Status Change StatisticsBI5Status Change Pump statusBI6Status Change DHW statusBI7Status Change CH statusBI8Status Change Demand Modulation statusBI9Status Change Sensor statusBI10Status Change Burner control statusBI11Status Change Active LockoutBI12Configuration Change PCB configurationBI13Configuration Change PIM configurationBI14Configuration Change Lead Lag configurationBI15Configuration Change Frost protection configurationBI16Configuration Change Outdoor reset configurationBI17Configuration Change Anti-condensation configurationBI18Configuration Change limits configurationBI19Configuration Change DHW configurationBI20Configuration Change Annunciation configurationBI21Configuration Change Pump configurationBI22Configuration Change Fan configurationBI23Configuration ChangeB urner control configurationBI24Configuration Change CH configurationBI25Configuration Change Modulation configurationBI26Configuration Change System configurationBI27Configuration Change Safety relayBI28Configuration Change Time of DayBI29Configuration Change STAT (Demand)BI30Configuration Change High Fire Switch (HFS)BI31Configuration Change Low Fire Switch (LFS)BI32Configuration Change Load Control Input(LCI)BI33Configuration Change Pre-ignition interlock (PII)BI34Configuration Change Interlock (ILK)BI35Configuration Change AlarmBI36Configuration Change Main valveBI37Configuration Change Pilot valveBI38Configuration Change External ignitionBI39Configuration Change Blower motor/HSIBI40Configuration Change Pump CBI41Configuration Change Pump BBI42Configuration Change Pump ABI43Annunciation I/O Annunciator 8/LFSBI44Annunciation I/O Annunciator 7/HFSBI45Annunciation I/O Annunciator 6BI46Annunciation I/O Annunciator 5BI47Annunciation I/O Annunciator 4BI48Annunciation I/O Annunciator 3BI49Annunciation I/O Annunciator 2BI50Annunciation I/O Annunciator 1/IASBI51Limits Heat exchanger high limitBI52Limits Exchanger T-rise limitBI53Limits Outlet T-rise limitBI54Limits Inversion inlet/exchanger limitBI55Limits Inversion exchanger/outlet limitBI56Limits Inversion inlet/outlet limitBI57Limits Delta T inlet/exchanger limitBI58Limits Delta T exchanger/outlet limitBI59Limits Delta T inlet/outlet limitBI60Limits Stack limitBI61Limits DHW high limitBI62Limits Outlet high limitBI63Plug-In Module (PIM) Status OEM alert PCB stored in PIMBI64Plug-In Module (PIM) Status OEM range PCB stored in PIMBI65Plug-In Module (PIM) Status Valid copyrightBI66Plug-In Module (PIM) Status Lead/Lag enabledBI67Plug-In Module (PIM) Status PIM installedAI68Demand sourceAI69Outlet (S3S4) or Outlet limit (S3) sensorAI70Firing rateAI71Fan speedAI72Flame signalAI73Inlet (S1) sensorAI74DHW (S6S7) or DHW limit (S6) sensorAI75S5 sensorAI76Stack (S8S9) or Stack limit (S8) sensorAI774-20 mA remote control input (S2) terminalAI78Active CH setpointAI79Active DHW setpointAI80Active LL setpointAO81Register Access StatusAI82Steam pressureAI83Analog modulation inputAI84Active CH pressure setpointBI85Extended Status Change DHW plate heat exchanger configurationBI86Extended Status Change DHW plate heat exchanger statusAI87Burner control statusAI88Burner control stateAI89Lockout codeAI90Alarm reasonAI91Annunciator first outAI92Annunciator holdAI93Sequence timeAI94Delay timeAI95Hold codeAI96Burner control flagsAI97Remote StatAI98Outlet operation (S4=J8-10) terminalAI99DHW operation (S7=J9-3) terminalAI100Stack or Heat exchanger operation (S9=J9-6)AI101Outlet operation sensor (S4=J8-10) stateAI102DHW operation sensor (S7=J9-3) stateAI103Outlet limit sensor (S3=J8-8) StateAI104Inlet sensor (S1=J8-4) stateAI105DHW limit sensor (S7=J9-1) StateAI106Stack limit sensor (S8=J9-4) StateAI107S5 (J8-11) sensor stateAI1084-20mA remote control input(S2=J8-6) stateAI109Pressure sensor (S1=J8-4) stateAI110Stack operation or Heat exchanger sensor (S9=J9-6) StateAI111Active rate limiterAI112Limited rateAI113Active rate overrideAI114Override rateAI115Demand rateAI116CH statusAI117CH setpoint sourceAI118CH heat demandAI119CH burner demandAI120CH requested rateAI121CH frost heat demandAI122CH frost burner demandAI123Active CH on hysteresisAI124Active CH off hysteresisAI125Active CH pressure on hysteresisAI126Active CH pressure off hysteresisAI127DHW statusAI128DHW setpoint sourceAI129DHW priority countAI130DHW heat demandAI131DHW burner demandAI132DHW requested rateAI133DHW frost heat demandAI134DHW frost burner demandAI135Active DHW on hysteresisAI136Active DHW off hysteresisAI137DHW storage timeAI138DHW storage heat demandAI139DHW storage burner demandBI140Pump A status Auxiliary 2 pump demandBI141Pump A status Auxiliary 1 pump demandBI142Pump A status System pump demandBI143Pump A status Boiler pump demandBI144Pump A status DHW pump demandBI145Pump A status CH pump demandBI146Pump A status Pump assigned to logical pumpBI147Pump A status Pump exercise requestedBI148Pump A status On due to exerciseBI149Pump A status On due to overrunBI150Pump A status Forced offBI151Pump A status Forced onBI152Pump A status On due to normal demandBI153Pump B status Auxiliary 1 pump demandBI154Pump B status System pump demandBI155Pump B status Boiler pump demandBI156Pump B status DHW pump demandBI157Pump B status CH pump demandBI158Pump B status Pump Bssigned to logical pumpBI159Pump B status Pump exercise requestedBI160Pump B status On due to exerciseBI161Pump B status On due to overrunBI162Pump B status Forced offBI163Pump B status Forced onBI164Pump B status On due to normal demandAI165CH pump start delay timeAI166CH pump statusAI167CH pump overrun timeAI168CH FP overrun timeAI169CH pump idle days countAI170DHW pump statusAI171DHW pump start delay timeAI172DHW pump overrun timeAI173DHW FP overrun timeAI174DHW pump idle days countAI175System pump statusAI176System pump overrun timeAI177System pump idle days countAI178Boiler pump statusAI179Boiler pump overrun timeAI180Boiler pump idle days countAI181Auxiliary 1 pump statusAI182Auxiliary 1 pump idle days countAI183Auxiliary 2 pump statusAI184Auxiliary 2 pump overrun timeAI185Auxiliary 2 pump idle days countAI186Auxiliary 1 pump overrun timeAO187Burner cycle countAO188Burner run timeAO189CH pump cycle countAO190DHW pump cycle countAO191System pump cycle countAO192Boiler pump cycle countAO193Auxiliary pump cycle countAO194Controller cycle countAI195Controller run timeAI196Auxiliary 2 pump cycle count R/WAI197Auxiliary 2 pump start delay timeAI198Boiler pump start delay timeAI199System pump start delay timeAI200Auxiliary 1 pump start delay timeAI201DHW tap heat demandAI202DHW preheat demandAI203DHW change rateAI204DHW tap on recognition timeAI205DHW tap on timeAI206DHW preheat delay after tap timeAI207DHW preheat on recognition timeAI208DHW preheat on timeAI209Lead Lag master statusBI210Lead Lag slave status Slave command receivedBI211Lead Lag slave status Slave mode has priority over CH DHWBI212Lead Lag slave status Slave is modulatingBI213Lead Lag slave status CH frost protection requestBI214Lead Lag slave status DHW frost protection requestBI215Lead Lag slave status Frost protection burner requestBI216Lead Lag slave status Local frost protection requestBI217Lead Lag slave status Burner control status (see register 32)AI218Lead Lag master setpoint sourceAI219Lead Lag master heat demandAI220Lead Lag slave burner demandAI221Lead Lag slave requested rateBI222Pump C status Auxiliary 2 pump demandBI223Pump C status Auxiliary 1 pump demandBI224Pump C status System pump demandBI225Pump C status Boiler pump demandBI226Pump C status DHW pump demandBI227Pump C status CH pump demandBI228Pump C status Pump assigned to logical pumpBI229Pump C status Pump exercise requestedBI230Pump C status On due to exerciseBI231Pump C status On due to overrunBI232Pump C status Forced offBI233Pump C status Forced onBI234Pump C status On due to normal demandAI235Outdoor temperatureAI236Outdoor sensor stateAI237Outlet T-rise rateAI238Exchanger T-rise rateAI239S10 sensor readingAI240S10 sensor stateAI241Product typeAO242PasswordAO243Temperature unitsAO244Antishort cycle timeAO245Alarm silence timeAO246Power up with lockoutAO247Reset and restartAO248Burner nameAO249Installation dataAO250OEM IDAI251OS numberAI252Date codeAI253Safety Processor buildAI254Application Processor buildAO255Installer passwordAO256OEM passwordAO257Modulation outputAO258CH maximum modulation rateAO259DHW maximum modulation rateAO260Minimum modulation rateAO261Prepurge rateAO262Lightoff rateAO263Postpurge rateAO264CH forced rateAO265CH forced rate timeAO266DHW forced rateAO267DHW forced rate timeAO268Burner switchAO269Firing rate controlAO270Manual firing rateAO271Analog output hysteresisAO272Standby rateAO273CH enableAO274CH demand switchAO275CH modulation sensorAO276CH setpointAO277CH time of day setpointAO278CH on hysteresisAO279CH off hysteresisAO280CH outdoor reset enableAO281CH P-gainAO282CH I-gainAO283CH D-gainAO284CH hysteresis step timeAO285CH pressure setpointAO286CH pressure on hysteresisAO287CH pressure off hysteresisAO288Ignition sourceAO289BLR/HSI functionAO290Igniter on duringAO291Pilot typeAO292Flame sensor typeAO293Purge rate provingAO294Lightoff rate provingAO295Prepurge timeAO296Pre-ignition timeAO297Pilot flame establishing period (PFEP)AO298Main flame establishing period (MFEP)AO299Run stabilization timeAO300Postpurge timeAO301Interlock start check enableAO302Interlock open responseAO303Ignite failure responseAO304Ignite failure retriesAO305Ignite failure delayAO306MFEP flame failure responseAO307Run flame failure responseAO308Pilot test holdAO309Interrupted air switch (IAS) enableAO310IAS start check enableAO311LCI enableAO312PII enableAO313Flame thresholdAO314ILK bounce detectionAO315Forced recycle interval timeAO316Absolute maximum fan speedAO317Absolute minimum fan speedAO318Fan PWM frequencyAO319Fan pulses per revolutionAO320Fan speed-up rampAO321Fan slow-down rampAO322Fan gain upAO323Fan gain downAO324Fan minimum duty cycleAO325CH pump outputAO326CH pump controlAO327CH pump overrun timeAO328CH FP pump overrun timeAO329DHW pump outputAO330DHW pump controlAO331DHW pump overrun timeAO332DHW FP pump overrun time R/WAO333DHW pump start delayAO334Boiler pump outputAO335Boiler pump controlAO336Boiler pump overrun timeAO337Auxiliary 1 pump outputAO338Auxiliary 1 pump controlAO339System pump outputAO340System pump controlAO341System pump overrun timeAO342Pump exercise intervalAO343Pump exercise timeAO344CH pump start delayAO345Boiler pump start delayAO346System pump start delayAO347Auxiliary 1 pump start delayBO348CH pump options 1 Normal pump demand when aux pump Z is setBO349CH pump options 1 Normal pump demand when aux pump Y is setBO350CH pump options 1 Normal pump demand when aux pump X is setBO351CH pump options 1 Normal pump demand when DHW service is activeBO352CH pump options 1 Normal pump demand when CH service is activeBO353CH pump options 1 Normal pump demand when DHW demandBO354CH pump options 1 Normal pump demand when CH demandBO355CH pump options 1 Normal pump demand when local burner demandBO356CH pump options 1 Local demand inhibited for faultsBO357CH pump options 2 Pump used for Lead LagBO358CH pump options 2 Pump used for local demandBO359CH pump options 2 Force pump off when DHW high limitBO360CH pump options 2 Force pump off when DHW anti-condensationBO361CH pump options 2 Force pump off when CH anti-condensationBO362CH pump options 2 Force pump off when DHW priority is activeBO363CH pump options 2 Force pump on when DHW frost protectionBO364CH pump options 2 Force pump on when CH frost protectionBO365CH pump options 2 Force pump on when Lead Lag slave demandBO366CH pump options 2 Force pump on when local burner demandBO367CH pump options 2 Force pump on when Outlet high limitBO368DHW pump options 1 Normal pump demand when aux pump Z is setBO369DHW pump options 1 Normal pump demand when aux pump Y is setBO370DHW pump options 1 Normal pump demand when aux pump X is setBO371DHW pump options 1 Normal pump demand when DHW is activeBO372DHW pump options 1 Normal pump demand when CH is activeBO373DHW pump options 1 Normal pump demand when DHW demandBO374DHW pump options 1 Normal pump demand when CH demandBO375DHW pump options 1 Normal pump demand when local burner demandBO376DHW pump options 1 Local demand inhibited for faultsBO377DHW pump options 2 Pump used for Lead LagBO378DHW pump options 2 Pump used for local demandBO379DHW pump options 2 Force pump off when DHW high limitBO380DHW pump options 2 Force pump off when DHW anti-condensationBO381DHW pump options 2 Force pump off when CH anti-condensationBO382DHW pump options 2 Force pump off when DHW priority is activeBO383DHW pump options 2 Force pump on when DHW frost protectionBO384DHW pump options 2 Force pump on when CH frost protectionBO385DHW pump options 2 Force pump on when Lead Lag slave demandBO386DHW pump options 2 Force pump on when local burner demandBO387DHW pump options 2 Force pump on when Outlet high limitBO388Boiler pump options 1 Normal pump demand when aux pump Z is setBO389Boiler pump options 1 Normal pump demand when aux pump Y is setBO390Boiler pump options 1 Normal pump demand when aux pump X is setBO391Boiler pump options 1 Normal pump demand when DHW is activeBO392Boiler pump options 1 Normal pump demand when CH is activeBO393Boiler pump options 1 Normal pump demand when DHW demandBO394Boiler pump options 1 Normal pump demand when CH demandBO395Boiler pump options 1 Normal pump demand local burner demandBO396Boiler pump options 1 Local demand inhibited for faultsBO397Boiler pump options 2 Pump used for Lead LagBO398Boiler pump options 2 Pump used for local demandBO399Boiler pump options 2 Force pump off when DHW high limitBO400Boiler pump options 2 Force pump off when DHW anti-condensationBO401Boiler pump options 2 Force pump off when CH anti-condensationBO402Boiler pump options 2 Force pump off HW priority is activeBO403Boiler pump options 2 Force pump on when DHW frost protectionBO404Boiler pump options 2 Force pump on when CH frost protectionBO405Boiler pump options 2 Force pump on when Lead Lag slave demandBO406Boiler pump options 2 Force pump on when local burner demandBO407Boiler pump options 2 Force pump on when Outlet high limitBO408System pump options 1 Normal pump demand when aux pump Z is setBO409System pump options 1 Normal pump demand when pump Y is setBO410System pump options 1 Normal pump demand when aux pump X is setBO411System pump options 1 Normal pump demand DHW service is activeBO412System pump options 1 Normal pump demand CH service is activeBO413System pump options 1 Normal pump demand DHW demandBO414System pump options 1 Normal pump demand when CH demandBO415System pump options 1 Normal pump demand local burner demandBO416System pump options 1 Local demand inhibited for faultsBO417System pump options 2 Pump used for Lead LagBO418System pump options 2 Pump used for local demandBO419System pump options 2 Force pump off when DHW high limitBO420System pump options 2 Force pump off when DHW anti-condensationBO421System pump options 2 Force pump off when CH anti-condensationBO422System pump options 2 Force pump off DHW priority is activeBO423System pump options 2 Force pump on DHW frost protectionBO424System pump options 2 Force pump on when CH frost protectionBO425System pump options 2 Force pump on when Lead Lag slave demandBO426System pump options 2 Force pump on when local burner demandBO427System pump options 2 Force pump on when Outlet high limitAO428Annunciation enableAO429Annunciator modeAO430Annunciator 1 configuration word 01AO431Annunciator 1 configuration word 02AO432Annunciator 1 configuration word 03AO433Annunciator 1 configuration word 04AO434Annunciator 1 configuration word 05AO435Annunciator 1 configuration word 06AO436Annunciator 1 configuration word 07AO437Annunciator 1 configuration word 08AO438Annunciator 1 configuration word 09AO439Annunciator 1 configuration word 10AO440Annunciator 1 configuration word 11AO441Annunciator 1 configuration word 12AO442Annunciator 1 configuration word 13AO443Annunciator 2 configuration word 01AO444Annunciator 2 configuration word 02AO445Annunciator 2 configuration word 03AO446Annunciator 2 configuration word 04AO447Annunciator 2 configuration word 05AO448Annunciator 2 configuration word 06AO449Annunciator 2 configuration word 07AO450Annunciator 2 configuration word 08AO451Annunciator 2 configuration word 09AO452Annunciator 2 configuration word 10AO453Annunciator 2 configuration word 11AO454Annunciator 2 configuration word 12AO455Annunciator 2 configuration word 13AO456Annunciator 3 configuration word 01AO457Annunciator 3 configuration word 02AO458Annunciator 3 configuration word 03AO459Annunciator 3 configuration word 04AO460Annunciator 3 configuration word 05AO461Annunciator 3 configuration word 06AO462Annunciator 3 configuration word 07AO463Annunciator 3 configuration word 08AO464Annunciator 3 configuration word 09AO465Annunciator 3 configuration word 10AO466Annunciator 3 configuration word 11AO467Annunciator 3 configuration word 12AO468Annunciator 3 configuration word 13AO469Annunciator 4 configuration word 01AO470Annunciator 4 configuration word 02AO471Annunciator 4 configuration word 03AO472Annunciator 4 configuration word 04AO473Annunciator 4 configuration word 05AO474Annunciator 4 configuration word 06AO475Annunciator 4 configuration word 07AO476Annunciator 4 configuration word 08AO477Annunciator 4 configuration word 09AO478Annunciator 4 configuration word 10AO479Annunciator 4 configuration word 11AO480Annunciator 4 configuration word 12AO481Annunciator 4 configuration word 13AO482Annunciator 5 configuration word 01AO483Annunciator 5 configuration word 02AO484Annunciator 5 configuration word 03AO485Annunciator 5 configuration word 04AO486Annunciator 5 configuration word 05AO487Annunciator 5 configuration word 06AO488Annunciator 5 configuration word 07AO489Annunciator 5 configuration word 08AO490Annunciator 5 configuration word 09AO491Annunciator 5 configuration word 10AO492Annunciator 5 configuration word 11AO493Annunciator 5 configuration word 12AO494Annunciator 5 configuration word 13AO495Annunciator 6 configuration word 01AO496Annunciator 6 configuration word 02AO497Annunciator 6 configuration word 03AO498Annunciator 6 configuration word 04AO499Annunciator 6 configuration word 05AO500Annunciator 6 configuration word 06AO501Annunciator 6 configuration word 07AO502Annunciator 6 configuration word 08AO503Annunciator 6 configuration word 09AO504Annunciator 6 configuration word 10AO505Annunciator 6 configuration word 11AO506Annunciator 6 configuration word 12AO507Annunciator 6 configuration word 13AO508Annunciator 7 configuration word 01AO509Annunciator 7 configuration word 02AO510Annunciator 7 configuration word 03AO511Annunciator 7 configuration word 04AO512Annunciator 7 configuration word 05AO513Annunciator 7 configuration word 06AO514Annunciator 7 configuration word 07AO515Annunciator 7 configuration word 08AO516Annunciator 7 configuration word 09AO517Annunciator 7 configuration word 10AO518Annunciator 7 configuration word 11AO519Annunciator 7 configuration word 12AO520Annunciator 7 configuration word 13AO521Annunciator 8 configuration word 01AO522Annunciator 8 configuration word 02AO523Annunciator 8 configuration word 03AO524Annunciator 8 configuration word 04AO525Annunciator 8 configuration word 05AO526Annunciator 8 configuration word 06AO527Annunciator 8 configuration word 07AO528Annunciator 8 configuration word 08AO529Annunciator 8 configuration word 09AO530Annunciator 8 configuration word 10AO531Annunciator 8 configuration word 11AO532Annunciator 8 configuration word 12AO533Annunciator 8 configuration word 13AO534PII configuration word 01AO535PII configuration word 02AO536PII configuration word 03AO537PII configuration word 04AO538PII configuration word 05AO539PII configuration word 06AO540PII configuration word 07AO541PII configuration word 08AO542PII configuration word 09AO543PII configuration word 10AO544PII configuration word 11AO545PII configuration word 12AO546LCI configuration word 01AO547LCI configuration word 02AO548LCI configuration word 03AO549LCI configuration word 04AO550LCI configuration word 05AO551LCI configuration word 06AO552LCI configuration word 07AO553LCI configuration word 08AO554LCI configuration word 09AO555LCI configuration word 10AO556LCI configuration word 11AO557LCI configuration word 12AO558ILK configuration word 01AO559ILK configuration word 02AO560ILK configuration word 03AO561ILK configuration word 04AO562ILK configuration word 05AO563ILK configuration word 06AO564ILK configuration word 07AO565ILK configuration word 08AO566ILK configuration word 09AO567ILK configuration word 10AO568ILK configuration word 11AO569ILK configuration word 12AO570DHW enableAO571DHW demand switchAO572DHW priority vs CHAO573DHW priority vs LLAO574DHW priority timeAO575DHW setpointAO576DHW time of day setpointAO577DHW on hysteresisAO578DHW off hysteresisAO579DHW P-gainAO580DHW I-gainAO581DHW D-gainAO582DHW hysteresis step timeAO583DHW modulation sensorAO584DHW priority sourceAO585Outlet high limit setpointAO586Outlet high limit responseAO587Stack limit enableAO588Stack limit setpointAO589Stack limit responseAO590Stack limit delayAO591Delta-T inlet/outlet enableAO592Delta-T inlet/outlet degreesAO593Delta-T responseAO594Delta-T delayAO595DHW high limit enableAO596DHW high limit setpointAO597DHW high limit responseAO598CH slow start enableAO599DHW slow start enableAO600Slow start rampAO601Slow start setpointAO602Outlet T-rise enableAO603Outlet T-rise degreesAO604Outlet T-rise delayAO605Outlet high limit enableAO606Delta-T retry limitAO607Delta-T rate limit enableAO608Delta-T inverse limit timeAO609Delta-T inverse limit responseAO610Delta-T exchanger/outlet enableAO611Delta-T exchanger/outlet degreesAO612Exchanger T-rise enableAO613T-rise responseAO614T-rise retry limitAO615Delta-T inlet/exchanger enableAO616Delta-T inlet/exchanger degreesAO617CH anticondensation enableAO618CH anticondensation setpointAO619CH anticondensation pump force offAO620DHW anticondensation enableAO621DHW anticondensation setpointAO622DHW anticondensation pump force offBO623Anticondensation priority Outlet high limitBO624Anticondensation priority Forced rateBO625Anticondensation priority Slow startBO626Anticondensation priority Delta-T limitBO627Anticondensation priority Stack limitAO628Frost protection anticondensation enableAO629DHW storage enableAO630DHW storage timeAO631DHW storage setpointAO632DHW storage on hysteresisAO633DHW storage off hysteresisAO634DHW priority methodAO635CH ODR maximum outdoor temperatureAO636CH ODR minimum outdoor temperatureAO637CH ODR low water temperatureAO638CH ODR boost timeAO639CH ODR maximum off pointAO640Lead Lag CH ODR maximum outdoor temperatureAO641Lead Lag CH ODR minimum outdoor temperatureAO642Lead Lag CH ODR low water temperatureAO643Lead Lag CH ODR boost timeAO644Lead Lag CH ODR maximum off pointAO645CH ODR boost stepAO646CH ODR boost recovery step timeAO647Lead Lag CH ODR boost stepAO648Lead Lag CH ODR boost recovery step timeAO649Minimum boiler water temperatureAO650Lead Lag CH ODR minimum water temperatureAO651CH frost protection enableAO652DHW frost protection enable R/WAO653Outdoor frost protection setpointAO654Lead Lag frost protection enableAO655Lead Lag frost protection rateAO656IAS open modulation enableAO657IAS open rate differentialAO658IAS open modulation step rateAO659IAS open modulation step timeAO660IAS closed responseAO661CH minimum pressureAO662CH time of day pressure setpointAO663Analog input hysteresisAO664Lead Lag slave enableAO665Lead Lag master enableAO666Lead Lag setpointAO667Lead Lag time of day setpointAO668Lead Lag outdoor reset enableAO669Lead Lag on hysteresisAO670Lead Lag off hysteresisAO671Lead Lag hysteresis step timeAO672Lead Lag P-gainAO673Lead Lag I-gainAO674Lead Lag D-gainAO675Lead Lag operation switchAO676Lead Lag CH demand switchAO677Lead Lag CH setpoint sourceAO678Lead Lag modulation sensorAO679Lead Lag modulation backup sensorAO680Lead Lag CH 4 mA water temperatureAO681Lead Lag CH 20 mA water temperatureAO682Lead Lag CH Modbus setpointAO683Lead Lag CH Modbus STATAO684Slave modeBO685Slave command Slave demand requestBO686Slave command Slave suspend startupBO687Slave command Slave run fan requestBO688Slave command Turn on auxiliary pump XBO689Slave command Turn on auxiliary pump YBO690Slave command Turn on auxiliary pump ZBO691Slave command Commanded rate is binary fraction %BO692Slave command Commanded rate bit 7BO693Slave command Commanded rate bit 6BO694Slave command Commanded rate bit 5BO695Slave command Commanded rate bit 4BO696Slave command Commanded rate bit 3BO697Slave command Commanded rate bit 2BO698Slave command Commanded rate bit 1BO699Slave command Commanded rate bit 0AO700Base load rateAO701Fan during off cycle rateAO702Slave sequence orderAO703Lead Lag Modbus portAO704Slave demand to firing delay R/WAO705Slave capacityAO706Base load common rateAO707Rate allocation methodAO708Lead allocation methodAO709Lag allocation methodAO710CH Modbus STATAO711CH setpoint sourceAO712CH Modbus setpointAO713CH modulation rate sourceAO714CH Modbus rateAO715CH priority vs. Lead LagAO716CH 4mA water temperatureAO717CH 20mA water temperatureAO718CH 4mA steam pressureAO719CH 20mA steam pressureAO720Heat exchanger high limit enableAO721Heat exchanger high limit setpointAO722Heat exchanger high limit responseAO723Heat exchanger high limit delayAO724Heat exchanger retry limitAO725S1 (J8-4) connector type (inlet sensor)AO726S2 (J8-6) connector type(4-20mA remote control input)AO727S3S4 (J8-8 10) connector typeAO728S5 (J8-11) connector typeAO729S6S7 (J9-1 3) connector typeAO730S8S9 (J9-4 6) connector typeAO731S10 (J10-7) connector typeAO732Installer passcodeAO733OEM passcodeAO734Outdoor temperature sourceAO735Warm weather shutdown enableAO736Warm weather shutdown setpointAO737Use STAT with EnviraCOM remote statAO738Plate preheat delay after tapAO739Plate preheat setpointAO740Plate preheat on recognition timeAO741Plate preheat on hysteresisAO742Plate preheat off hysteresisAO743Plate preheat minimum on timeAO744Tap detect degreesAO745Tap detect on hysteresisAO746Tap detect on recognition timeAO747Tap stop DHW-Inlet degreesAO748Tap stop Outlet-Inlet degreesAO749Tap detect minimum on timeAO750Lead Lag DHW demand switchAO751Lead Lag DHW setpointAO752Lead Lag DHW priority vs. CHAO753Warm weather shutdown enableAO754Warm weather shutdown setpointAO755Slave dropout/return compensationAO756Add stage methodAO757Add stage detection timeAO758Add stage error thresholdAO759Add stage rate offsetAO760Add stage error gainAO761Add stage rate gainAO762Add stage inter-stage delayAO763Drop stage methodAO764Drop stage detection timeAO765Drop stage error thresholdAO766Drop stage rate offsetAO767Drop stage error gainAO768Drop stage rate gainAO769Drop stage inter-stage delayAO770Lead rotation timeAO771Force lead rotation timeAO772Auxiliary 1 pump overrun timeBO773Aux 1 pump option 1 Normal demand when aux pump Z is setBO774Aux 1 pump option 1 Normal demand when aux pump Y is setBO775Aux 1 pump option 1 Normal demand when aux pump X is setBO776Aux 1 pump option 1 Normal demand when DHW service is activeBO777Aux 1 pump option 1 Normal demand when CH service is activeBO778Aux 1 pump option 1 Normal demand when DHW demandBO779Aux 1 pump option 1 Normal demand when CH demandBO780Aux 1 pump option 1 Normal demand when local burner demandBO781Aux 1 pump option 1 Local demand inhibited for faultsBO782Aux 1 pump options 2 Pump used for Lead LagBO783Aux 1 pump options 2 Pump used for local demandBO784Aux 1 pump options 2 Force pump off when DHW high limitBO785Aux 1 pump options 2 Force pump off when DHW anti-condensationBO786Aux 1 pump options 2 Force pump off when CH anti-condensationBO787Aux 1 pump options 2 Force pump off when DHW priority is activeBO788Aux 1 pump options 2 Force pump on when DHW frost protectionBO789Aux 1 pump options 2 Force pump on when CH frost protectionBO790Aux 1 pump options 2 Force pump on when Lead Lag slave demandBO791Aux 1 pump options 2 Force pump on when local burner demandBO792Aux 1 pump options 2 Force pump on when Outlet high limitAO793Auxiliary 2 pump outputAO794Auxiliary 2 pump controlAO795Auxiliary 2 pump start delayAO796Auxiliary 2 pump overrun timeBO797Aux 2 pump option 1 Normal demand when aux pump Z is setBO798Aux 2 pump option 1 Normal demand when aux pump Y is setBO799Aux 2 pump option 1 Normal demand when aux pump X is setBO800Aux 2 pump option 1 Normal demand when DHW service is activeBO801Aux 2 pump option 1 Normal demand when CH service is activeBO802Aux 2 pump option 1 Normal demand when DHW demandBO803Aux 2 pump option 1 Normal demand when CH demandBO804Aux 2 pump option 1 Normal demand when local burner demandBO805Aux 2 pump option 1 Local demand inhibited for faultsBO806Aux 2 pump option 1 Pump used for Lead LagBO807Aux 2 pump option 1 Pump used for local demandBO808Aux 2 pump option 1 Force pump off when DHW high limitBO809Aux 2 pump option 1 Force pump off when DHW anti-condensationBO810Aux 2 pump option 1 Force pump off when CH anti-condensationBO811Aux 2 pump option 1 Force pump off when DHW priority is activeBO812Aux 2 pump option 1 Force pump on when DHW frost protectionBO813Aux 2 pump option 1 Force pump on when CH frost protectionBO814Aux 2 pump option 1 Force pump on when Lead Lag slave demandBO815Aux 2 pump option 1 Force pump on when local burner demandBO816Aux 2 pump option 1 Force pump on when Outlet high limit
Integration notes
- Built from Contemporary Controls' BASgatewayLX Modbus device profile CleaverBrooks_Falcon_b_LX.csv; the profile maps the registers in the Falcon Modbus guide (750-308) (https://www.ccontrols.com/support/dp/750-308FalconModbus.pdf).
- Object instances are the ones this profile assigns when it is loaded into the gateway. A site that edited or rebuilt the profile may use different instances.
- Only 7 of the 816 rows are flagged for polling in the profile; the rest are served only after you tick them in the gateway. Their descriptions say "not polled by default".
- The CSV has no read/write column: Analog/Binary Inputs are read-only and Analog/Binary Outputs are commandable (priority array), which is how the gateway maps them (access inferred). Descriptions give the Modbus register each object reads.
- Some names appear more than once in the profile as published (CH setpoint source; DHW storage time; CH pump overrun time...); they are kept as printed and told apart by instance.
Check it against the live device. A points list tells you what the controller can expose; the unit in front of you may differ by firmware or installed options. This list is provided as-is for reference only and may contain mistakes — confirming it before you write, map or commission anything is up to you (terms). Easy BACnet scans a network for BACnet IP devices from an Android phone, reads every object on the Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLX and exports what it actually has to Excel — free. New to BACnet? Start with what a BACnet points list is and what the object types mean.
Questions about the Contemporary Controls Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLX
How many BACnet points does the Contemporary Controls Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLX have?
This list has 816 BACnet objects: 121 analog inputs, 440 analog outputs, 115 binary inputs, 140 binary outputs. The exact set on a given unit depends on its firmware, installed options and configuration.
Which Contemporary Controls Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLX BACnet points are writable?
580 of the 816 objects accept a write. Points marked Command have a priority array: a write holds until it is released, so release it back to automatic when you are done. The source has no read/write column, so this is inferred from object type.
Where is the official Contemporary Controls Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLX BACnet documentation?
The source is BASgatewayLX Modbus device profile CleaverBrooks_Falcon_b (CleaverBrooks_Falcon_b_LX.csv), published free by Contemporary Controls at https://www.ccontrols.com/support/dp/CleaverBrooksFalcon2.zip.
What are the minimum BACnet points to integrate the Contemporary Controls Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLX?
Start with AO 276 CH setpoint (CH setpoint); AI 88 Burner control state (Burner control state); AI 69 Outlet (S3S4) or Outlet limit (S3) sensor (Outlet temperature); AI 78 Active CH setpoint (Active CH setpoint); AI 70 Firing rate (Firing rate); AI 72 Flame signal (Flame signal); AI 89 Lockout code (Lockout code (0 = none)); AI 90 Alarm reason (Alarm reason).
How do I check these points on the real Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLX?
Scan the network with a BACnet IP browser such as Easy BACnet, open the device and compare its object list with this table. Anything missing is usually an option that isn't installed or a point that is disabled in the controller's configuration.
More Contemporary Controls BACnet points lists
- Variable frequency drive (HVAC)
Contemporary Controls ABB ACH 400 via BASgatewayLX
ABB ACH 400 HVAC drives read over Modbus RTU by a Contemporary Controls BASgatewayLX.
Also known as: ABB ACH400, ACH400 drive, ACH 400 Modbus - Variable frequency drive (HVAC)
Contemporary Controls ABB ACH550 (ABB DRV FULL profile, 5305 = 2) via BASgatewayLX
ABB ACH550 HVAC drives on embedded fieldbus (Modbus RTU) with parameter 5305 = 2 (ABB DRV FULL profile), read by a BASgatewayLX.
Also known as: ACH550, ACH550 ABB DRV FULL, ABB_Drive_DRV_FULL_5305_is_2 - Variable frequency drive (HVAC)
Contemporary Controls ABB ACH550 (ABB DRV LIM profile, 5305 = 0) via BASgatewayLX
ABB ACH550 HVAC drives on embedded fieldbus (Modbus RTU) with parameter 5305 = 0 (ABB DRV LIM profile), read by a BASgatewayLX.
Also known as: ACH550, ACH550 ABB DRV LIM, ABB_Drive_DRV_LIM_5305_is_0 - Variable frequency drive (HVAC)
Contemporary Controls ABB ACH550 (DCU profile, 5305 = 1) via BASgatewayLX
ABB ACH550 HVAC drives on embedded fieldbus (Modbus RTU) with parameter 5305 = 1 (DCU profile), read by a BASgatewayLX.
Also known as: ACH550, ACH550 DCU profile, ABB_Drive_DCU_5305_is_1 - I/O module (analog inputs)
Contemporary Controls Acromag 961EN / 962EN Ethernet I/O module via BASgatewayLX
Acromag 961EN and 962EN Modbus TCP analog input modules, read by a BASgatewayLX.
Also known as: 961EN, 962EN, 961EN-4006, 962EN-4006, Acromag EtherStax - Boiler (modular cascade)
Contemporary Controls Advanced Thermal Hydronics (Hydrotherm) KN-2 / KN-4 via BASgatewayLX
Hydrotherm / Advanced Thermal Hydronics KN-2 and KN-4 modular boilers with the KN boiler-room controller on Modbus, read by a BASgatewayLX.
Also known as: Hydrotherm KN, KN-2, KN-4, Advanced Thermal Hydronics, Mastek KN - Boiler sequencer (boiler management system)
Contemporary Controls AERCO BMS / BMS II Boiler Management System via BASgatewayLX
AERCO BMS and BMS II boiler management systems on Modbus, read by a BASgatewayLX.
Also known as: AERCO BMS, AERCO BMS II, Boiler Management System, BMSII - Boiler controller
Contemporary Controls AERCO C-More Boiler Controller via BASgatewayLX
AERCO boilers and water heaters with the C-More control on Modbus, read by a BASgatewayLX.
Also known as: C-More, AERCO Benchmark C-More, KC1000 C-More - Chiller / heat pump controller
Contemporary Controls AERMEC chillers/heat pumps via AER485 interface via BASgatewayLX
AERMEC chillers and heat pumps fitted with the AER485 RS-485 Modbus interface, read by a BASgatewayLX.
Also known as: AER485, AERMEC Modbus, AERMEC chiller, AERMEC heat pump - Automatic transfer switch controller
Contemporary Controls ASCO 7000 Series Group 5 controller via BASgatewayLX
ASCO 7000 Series automatic transfer switches with the Group 5 controller on Modbus, read by a BASgatewayLX.
Also known as: ASCO Group 5, ASCO 7000 ATS, Group 5 controller, ASCO 7000 Series - Power meter (transfer switch power manager)
Contemporary Controls ASCO Power Manager Xp via BASgatewayLX
ASCO Power Manager Xp metering modules on ASCO transfer switches, read over Modbus by a BASgatewayLX.
Also known as: ASCO 5210, Power Manager Xp, ASCO PMXp, ASCO Power Manager - Refrigerant leak monitor (gas sensor, 16 zones)
Contemporary Controls Bacharach HGM-MZ multi-zone refrigerant monitor via BASgatewayLX
Bacharach HGM-MZ multi-zone halogen/refrigerant gas monitors on Modbus, read by a BASgatewayLX.
Also known as: HGM-MZ, Bacharach HGM MZ, Multi-Zone refrigerant monitor, 3015-5074 - Thermostat (single mode heat/cool/ventilation, BACnet MS/TP)
Contemporary Controls BASstat BAST-121C-B2 Single Mode Thermostat
Contemporary Controls BAST-121C-B2 wired thermostats for single-mode heating, cooling or ventilation equipment.
Also known as: BAST-121C-B2, BAST-121-B2, BASstat 121C - Thermostat (single mode heat/cool/ventilation, Wi-Fi BACnet IP)
Contemporary Controls BASstat BAST-121C-BW2 Wireless Single Mode Thermostat
Contemporary Controls BAST-121C-BW2 Wi-Fi thermostats for single-mode heating, cooling or ventilation equipment.
Also known as: BAST-121C-BW2, BAST-121-BW2, BASstat 121C Wi-Fi - Thermostat (multi-stage heat/cool, BACnet MS/TP)
Contemporary Controls BASstat BAST-221C/CH-B2 Multi-Stage Thermostat
Contemporary Controls BAST-221C and BAST-221CH (with humidity) wired thermostats for multi-stage heating, cooling and ventilation, such as rooftop units.
Also known as: BAST-221C-B2, BAST-221CH-B2, BASstat B2, BASstat 221C MS/TP - Thermostat (multi-stage heat/cool, Wi-Fi BACnet IP)
Contemporary Controls BASstat BAST-221C/CH-BW2 Wireless Multi-Stage Thermostat
Contemporary Controls BAST-221C and BAST-221CH (with humidity) Wi-Fi thermostats for multi-stage heating, cooling and ventilation, such as rooftop units.
Also known as: BAST-221C-BW2, BAST-221CH-BW2, BASstat BW2, BASstat 221C - Thermostat for 2-stage HP systems (BACnet MS/TP)
Contemporary Controls BASstat BAST-321HP-B2 Heat Pump Thermostat
Contemporary Controls BAST-321HP-B2 wired thermostats for single or dual compressor heat pumps with auxiliary heat.
Also known as: BAST-321HP-B2, BAST-321-B2, BASstat 321HP - Thermostat for 2-stage HP systems (Wi-Fi BACnet IP)
Contemporary Controls BASstat BAST-321HP-BW2 Wireless Heat Pump Thermostat
Contemporary Controls BAST-321HP-BW2 Wi-Fi thermostats for single or dual compressor heat pumps with auxiliary heat.
Also known as: BAST-321HP-BW2, BAST-321-BW2, BASstat 321HP Wi-Fi - Thermostat for modulating 4-pipe FCUs (BACnet MS/TP)
Contemporary Controls BASstat BAST-421C-B2 Modulating Fan Coil Thermostat
Contemporary Controls BAST-421C-B2 wired thermostats for 4-pipe fan coils with modulating or floating valves.
Also known as: BAST-421C-B2, BAST-421-B2, BASstat 421C MS/TP - Thermostat for modulating 4-pipe FCUs (Wi-Fi BACnet IP)
Contemporary Controls BASstat BAST-421C-BW2 Wireless Modulating Fan Coil Thermostat
Contemporary Controls BAST-421C-BW2 Wi-Fi thermostats for 4-pipe fan coils with modulating or floating valves.
Also known as: BAST-421C-BW2, BAST-421-BW2, BASstat 421C - Water treatment controller (pool chemistry)
Contemporary Controls BECS BECsys5 / BECsys7 / BECsysBW water chemistry controller via BASgatewayLX
BECS Technology BECsys5, BECsys7 and BECsysBW pool/aquatic water chemistry controllers on Modbus, read by a BASgatewayLX.
Also known as: BECsys5, BECsys7, BECsysBW, BECS Technology, BECsys Modbus - Soft starter (motor)
Contemporary Controls Benshaw RediStart RB2 / RC2 / RX2E soft starter via BASgatewayLX
Benshaw RediStart RB2, RC2 and RX2E solid-state soft starters on Modbus, read by a BASgatewayLX.
Also known as: RB2, RC2, RX2E, Benshaw RediStart, Benshaw soft starter Modbus - Power and energy meter
Contemporary Controls Carlo Gavazzi EM21 via BASgatewayLX
Carlo Gavazzi EM21 three-phase energy analyzers on Modbus RTU, read by a BASgatewayLX.
Also known as: EM21, EM21 72D, Carlo Gavazzi EM21 Modbus - Power and energy meter
Contemporary Controls Carlo Gavazzi EM24 via BASgatewayLX
Carlo Gavazzi EM24 three-phase energy meters on Modbus RTU, read by a BASgatewayLX.
Also known as: EM24, EM24-DIN, Carlo Gavazzi EM24 Modbus - Automatic transfer switch controller
Contemporary Controls Caterpillar ATC 300+ transfer switch controller via BASgatewayLX
Caterpillar transfer switches with the ATC 300+ controller on Modbus, read by a BASgatewayLX.
Also known as: ATC 300+, ATC300+, Cat ATS controller, Eaton ATC-300+ - Generator set controller
Contemporary Controls Caterpillar EMCP 4 generator set control via BASgatewayLX
Caterpillar generator sets with the EMCP 4 control panel (Modbus data link), read by a BASgatewayLX.
Also known as: EMCP 4, EMCP4, EMCP 4.2, EMCP 4.4, Cat genset Modbus - Power and energy meter
Contemporary Controls Crompton Instruments INTEGRA 15xx via BASgatewayLX
Crompton Instruments (TE) INTEGRA 1540/1560/1580 digital metering systems on Modbus, read by a BASgatewayLX.
Also known as: INTEGRA 1540, INTEGRA 1560, INTEGRA 1580, Crompton Integra Modbus, TE Crompton INTEGRA - Generator set controller
Contemporary Controls Cummins PowerCommand 2.x / 3.x genset control via BASgatewayLX
Cummins generator sets with PowerCommand 2.x or 3.x controls on Modbus, read by a BASgatewayLX.
Also known as: PowerCommand 2.2, PowerCommand 3.3, PCC 2.x, PCC 3.x, Cummins PCC Modbus - Generator set monitor
Contemporary Controls Cummins PowerCommand CCM-G genset monitoring via BASgatewayLX
Cummins generator sets monitored by a PowerCommand CCM-G (through the Cummins Modbus/LonWorks gateway), read by a BASgatewayLX.
Also known as: CCM-G, Cummins CCM-G, PowerCommand CCM, ModLon gateway - Variable frequency drive (HVAC)
Contemporary Controls Danfoss VLT HVAC Drive FC 102 via BASgatewayLX
Danfoss VLT HVAC Drive FC 102 on Modbus RTU (FC protocol set to Modbus), read by a BASgatewayLX.
Also known as: FC102, FC 102, VLT HVAC Drive, Danfoss FC-102 Modbus - Power and energy meter
Contemporary Controls E-Mon D-Mon Class 3200 / 3400 / 5000 via BASgatewayLX
E-Mon D-Mon Class 3200, 3400 and 5000 submeters on Modbus, read by a BASgatewayLX.
Also known as: E-Mon D-Mon 3200, E-Mon 3400, E-Mon 5000, Class 3200, Class 5000, Honeywell E-Mon - Pulse meter data recorder (meter interface)
Contemporary Controls E-Mon D-Mon IDR-8 / IDR-16 interval data recorder via BASgatewayLX
E-Mon D-Mon IDR-8 and IDR-16 interval data recorders (pulse-input meter recorders) on Modbus, read by a BASgatewayLX.
Also known as: IDR-8, IDR-16, E-Mon IDR, E-Mon interval recorder - Power and energy meter
Contemporary Controls Eaton IQ 250 / IQ 260 via BASgatewayLX
Eaton IQ 250 and IQ 260 electronic power meters on Modbus, read by a BASgatewayLX.
Also known as: IQ 250, IQ 260, IQ250, IQ260, Eaton IQ meter - Power and energy meter
Contemporary Controls Eaton IQ 300 via BASgatewayLX
Eaton IQ 300 power meters on Modbus, read by a BASgatewayLX.
Also known as: IQ 300, IQ300, Eaton IQ 300 meter - Motor overload relay (motor protection)
Contemporary Controls Eaton Motor Insight overload relay via BASgatewayLX
Eaton Motor Insight (C441) motor protection overload relays with Modbus, read by a BASgatewayLX.
Also known as: Motor Insight, C441, Eaton C441 Motor Insight, Cutler-Hammer Motor Insight - Lighting control panel (remote-operated breakers)
Contemporary Controls Eaton Pow-R-Command PRC100 / Mod100 lighting panel via BASgatewayLX
Eaton Pow-R-Command lighting control panelboards with remote-operated breakers (PRC100 / Mod100 controller), read over Modbus by a BASgatewayLX.
Also known as: Pow-R-Command, PRC100, Mod100, PRC1000, Eaton lighting control panelboard - Power and energy meter
Contemporary Controls Eaton Power Xpert PXM 2000 via BASgatewayLX
Eaton Power Xpert PXM 2000 series meters on Modbus, read by a BASgatewayLX.
Also known as: PXM 2000, PXM2000, PXM 2250, PXM 2260, PXM 2270, Power Xpert Meter 2000 - UPS (uninterruptible power supply)
Contemporary Controls Eaton Powerware 9390 UPS via BASgatewayLX
Eaton Powerware 9390 three-phase UPS systems on Modbus, read by a BASgatewayLX.
Also known as: Powerware 9390, Eaton 9390, 9390 UPS Modbus - Power and energy meter
Contemporary Controls Eaton RS-485 PONI (IQ product network interface) via BASgatewayLX
Eaton (Cutler-Hammer) IQ meters and trip units with an RS-485 PONI Modbus card, read by a BASgatewayLX (LO/HI word order).
Also known as: PONI, RS485 PONI, Eaton IQ PONI, Cutler-Hammer PONI - Boiler controller (cascade dependent)
Contemporary Controls ebm-papst ArgusVision Dependent Boiler via BASgatewayLX
Boilers with an ebm-papst ArgusVision control running as a dependent (cascade member), read over Modbus by a BASgatewayLX.
Also known as: ArgusVision, ebmpapst dependent boiler, Argus boiler control - Energy recovery ventilator (heat recovery unit)
Contemporary Controls ebm-papst ArgusVision Heat Recovery Unit (Basic) via BASgatewayLX
Heat recovery ventilation units with an ebm-papst ArgusVision control (basic map), read over Modbus by a BASgatewayLX.
Also known as: ArgusVision HRU, ebmpapst heat recovery unit, Argus HRU basic - Boiler controller (cascade managing)
Contemporary Controls ebm-papst ArgusVision Trio Managing Boiler via BASgatewayLX
Boilers with an ebm-papst ArgusVision control acting as the managing (lead) boiler of a cascade, read over Modbus by a BASgatewayLX.
Also known as: ArgusVision Trio, ebmpapst managing boiler, Argus cascade master - Elevator controller
Contemporary Controls Elevator Controls Corporation Pixel elevator controller via BASgatewayLX
Elevator Controls Corporation Pixel elevator controllers with Modbus monitoring, read by a BASgatewayLX.
Also known as: Pixel controller, ECC Pixel, Elevator Controls Pixel Modbus - Boiler burner management (parallel positioning)
Contemporary Controls Fireye PPC4000 parallel positioning control via BASgatewayLX
Fireye PPC4000 fuel/air parallel positioning controls on boilers, read over Modbus by a BASgatewayLX.
Also known as: PPC4000, PPC 4000, Fireye PPC-4000 - Thermal mass flow meter
Contemporary Controls Fox Thermal Instruments FT2 via BASgatewayLX
Fox Thermal Instruments FT2 thermal mass gas flow meters on Modbus, read by a BASgatewayLX.
Also known as: FT2, Fox FT2, Fox Thermal FT2 flow meter - Power and energy meter
Contemporary Controls GE EPM 2200 via BASgatewayLX
GE Multilin EPM 2200 power meters on Modbus, read by a BASgatewayLX.
Also known as: EPM 2200, EPM2200, GE Multilin EPM 2200 - Multi-circuit power and energy meter (submeter)
Contemporary Controls GE EPM 4500 multi-point submeter via BASgatewayLX
GE EPM 4500 multi-circuit submeters (up to 24 meter points) on Modbus, read by a BASgatewayLX.
Also known as: EPM 4500, EPM4500, GE Multilin EPM 4500 - Power and energy meter
Contemporary Controls GE EPM 6000 via BASgatewayLX
GE Multilin EPM 6000 power meters on Modbus, read by a BASgatewayLX.
Also known as: EPM 6000, EPM6000, GE Multilin EPM 6000 - Power and energy meter
Contemporary Controls GE Multilin PQMII via BASgatewayLX
GE Multilin PQMII power quality meters on Modbus, read by a BASgatewayLX ("lite" profile).
Also known as: PQMII, PQM II, GE Multilin PQM II, PQMII power quality meter - Automatic transfer switch controller
Contemporary Controls GE Zenith Controls MX200 transfer switch controller via BASgatewayLX
GE Zenith transfer switches with the MX200 microprocessor controller and Modbus card, read by a BASgatewayLX.
Also known as: MX200, Zenith MX200, ZTS MX200, GE Zenith ATS - Generator set controller
Contemporary Controls Generac G-Panel generator control via BASgatewayLX
Generac generator sets with the G-Panel control (Modbus), read by a BASgatewayLX.
Also known as: G-Panel, Generac G Panel, Generac Modbus G-Panel - Generator set controller
Contemporary Controls Generac H-100 control panel via BASgatewayLX
Generac industrial generator sets with the H-100 control panel on Modbus, read by a BASgatewayLX.
Also known as: H-100, H100, Generac H Panel, Generac H-Panel Modbus - Boiler controller
Contemporary Controls Harsco Patterson-Kelley NURO via BASgatewayLX
Patterson-Kelley NURO condensing boilers (Harsco) on Modbus, read by a BASgatewayLX.
Also known as: NURO, Patterson-Kelley NURO, Harsco Air-Xchange NURO, P-K NURO - Boiler burner control (flame safeguard)
Contemporary Controls Honeywell 7800 SERIES burner control (S7800A1142 display) via BASgatewayLX
Honeywell 7800 SERIES relay modules (RM/EC7800) with the S7800A1142 keyboard display module providing Modbus, read by a BASgatewayLX.
Also known as: S7800A1142, 7800 SERIES, RM7800, EC7800, Honeywell burner control Modbus - Air compressor controller
Contemporary Controls Ingersoll Rand XE-90M / XE-145M compressor controller via BASgatewayLX
Ingersoll Rand rotary screw air compressors with the Xe-90M or Xe-145M controller on Modbus, read by a BASgatewayLX.
Also known as: XE-90M, XE-145M, Xe-90M, Ingersoll Rand Xe controller - Generator set controller
Contemporary Controls Kohler Decision-Maker 550 generator controller via BASgatewayLX
Kohler generator sets with the Decision-Maker 550 controller on Modbus, read by a BASgatewayLX.
Also known as: Decision-Maker 550, DEC 550, Kohler DM550, Kohler genset Modbus - Automatic transfer switch controller
Contemporary Controls Kohler MPAC 1500 transfer switch controller via BASgatewayLX
Kohler transfer switches with the MPAC 1500 controller on Modbus, read by a BASgatewayLX.
Also known as: MPAC 1500, Kohler ATS, MPAC1500 - Precision cooling unit (computer room air handler)
Contemporary Controls Liebert iCOM v4 (Challenger 3000, Challenger ITR, CW, Deluxe System/3, DS, DSE, PeX, HPM) via BASgatewayLX
Liebert precision cooling units with iCOM v4 controls (Challenger 3000/ITR, CW, Deluxe System/3, DS, DSE, PeX, HPM), read over Modbus by a BASgatewayLX.
Also known as: iCOM v4, Liebert iCOM, Liebert DS, Liebert DSE, Liebert CW, Liebert PeX, Liebert HPM, Challenger 3000, Challenger ITR, Deluxe System/3 - Precision cooling unit (ceiling split)
Contemporary Controls Liebert Mini-Mate2 via BASgatewayLX
Liebert Mini-Mate2 ceiling-mounted precision cooling units on Modbus, read by a BASgatewayLX.
Also known as: Mini-Mate2, Mini Mate 2, Liebert MiniMate - UPS (uninterruptible power supply)
Contemporary Controls Liebert Series 600 UPS via BASgatewayLX
Liebert Series 600 UPS systems on Modbus, read by a BASgatewayLX.
Also known as: Series 600, Liebert 600T, Liebert UPS Modbus - Precision cooling unit (computer room air handler)
Contemporary Controls Liebert Table 27 units (LAM, Challenger 3000, Deluxe System/3, Himod, ICS) via BASgatewayLX
Older Liebert precision cooling units on the Advanced Microprocessor (LAM) control, Challenger 3000, Deluxe System/3, Himod (LNA) and ICS, read over Modbus by a BASgatewayLX (Liebert Modbus table 27).
Also known as: Liebert LAM, Advanced Microprocessor, Liebert Challenger 3000, Liebert Deluxe System/3, Liebert Himod, Liebert ICS, Liebert SiteScan - Boiler / water heater controller
Contemporary Controls Lochinvar Armor, Knight, FTXL and Wall Mount via BASgatewayLX
Lochinvar Knight (KB/KBX), Knight Wall Mount (WB), Armor (AW) and FTXL boilers and water heaters with SMART SYSTEM Modbus, read by a BASgatewayLX.
Also known as: Lochinvar Knight, Lochinvar Armor, FTXL, Knight Wall Mount, WB, AW, KB, KBX, SMART SYSTEM Modbus - Boiler controller
Contemporary Controls Lochinvar Crest boiler via BASgatewayLX
Lochinvar Crest commercial condensing boilers with SMART SYSTEM Modbus, read by a BASgatewayLX.
Also known as: Crest, Lochinvar Crest Modbus, FBN Crest - UPS (uninterruptible power supply)
Contemporary Controls Mitsubishi Electric 9900A UPS (Modbus TCP) via BASgatewayLX
Mitsubishi Electric 9900A series UPS on Modbus TCP, read by a BASgatewayLX.
Also known as: 9900A, 9900 UPS, Mitsubishi UPS Modbus TCP, MUCM 9900 - VRF indoor unit gateway (3 indoor units)
Contemporary Controls Mitsubishi Electric AG-150 central controller via Procon Mod-IP/50 via BASgatewayLX
Mitsubishi Electric City Multi VRF indoor units on an AG-150 central controller, read through the Procon Mod-IP/50 Modbus interface by a BASgatewayLX.
Also known as: Procon Mod-IP/50, AG-150, AG150, Mitsubishi City Multi Modbus, MitsubishiProcon - UPS (uninterruptible power supply)
Contemporary Controls Mitsubishi Electric UPS 1100/2033/7011/9800/9900 via Procon Mod-IP/50 (MUCM) via BASgatewayLX
Mitsubishi Electric 1100, 2033, 7011, 9800 and 9900 series UPS with the MUCM / Procon Mod-IP/50 Modbus interface, read by a BASgatewayLX.
Also known as: MUCM, Procon Mod-IP/50, Mitsubishi 1100 UPS, Mitsubishi 2033 UPS, Mitsubishi 7011 UPS, Mitsubishi 9800 UPS, Mitsubishi 9900 UPS - Heat-tracing controller
Contemporary Controls Pentair Raychem DigiTrace C910 heat-tracing controller via BASgatewayLX
Pentair (Raychem) DigiTrace C910 single-circuit heat-tracing controllers on Modbus, read by a BASgatewayLX.
Also known as: C910, DigiTrace C910, Raychem C910-485, Pentair heat trace controller - Water heater controller
Contemporary Controls PVI Industries TempTrac water heater control via BASgatewayLX
PVI Industries commercial water heaters with the TempTrac control on Modbus, read by a BASgatewayLX.
Also known as: TempTrac, PVI TempTrac, PVI water heater Modbus - Water heater controller
Contemporary Controls PVI Industries XR10CX controller via BASgatewayLX
PVI Industries water heaters using the XR10CX digital controller on Modbus, read by a BASgatewayLX.
Also known as: XR10CX, Dixell XR10CX, PVI XR10CX Modbus - Thermal mass flow meter
Contemporary Controls Sage Metering Sage Prime SIP / SRP via BASgatewayLX
Sage Metering Sage Prime insertion (SIP) and in-line (SRP) thermal mass gas flow meters on Modbus, read by a BASgatewayLX.
Also known as: Sage Prime, SIP, SRP, Sage Metering flow meter - Power and energy meter
Contemporary Controls Schneider Electric (Veris) Enercept meter via BASgatewayLX
Schneider Electric / Square D Enercept networked power meters on Modbus, read by a BASgatewayLX (HI/LO word order).
Also known as: Enercept, Square D Enercept, Veris Enercept H8035, H8036 Enercept - In-row precision cooling unit (chilled water)
Contemporary Controls Schneider Electric APC InRow RC (ACRC100 series) via BASgatewayLX
Schneider Electric APC InRow RC ACRC100-series in-row coolers on Modbus, read by a BASgatewayLX.
Also known as: ACRC100, ACRC103, InRow RC, APC InRow RC Modbus - In-row precision cooling unit (chilled water)
Contemporary Controls Schneider Electric APC InRow RC ACRC301 via BASgatewayLX
Schneider Electric APC InRow RC ACRC301 chilled-water in-row coolers on Modbus, read by a BASgatewayLX.
Also known as: ACRC301, ACRC301S, InRow RC 300 mm, APC InRow chilled water - UPS (uninterruptible power supply)
Contemporary Controls Schneider Electric APC Symmetra PX 250/500 kW UPS via BASgatewayLX
Schneider Electric APC Symmetra PX 250 kW and 500 kW UPS systems on Modbus, read by a BASgatewayLX.
Also known as: Symmetra PX 250, Symmetra PX 500, APC Symmetra PX, SY250K, SY500K - Power and energy meter
Contemporary Controls Schneider Electric PowerLogic CM4000 via BASgatewayLX
Schneider Electric (Square D) PowerLogic CM4000-series circuit monitors on Modbus, read by a BASgatewayLX.
Also known as: CM4000, CM4250, Square D CM4000, PowerLogic circuit monitor - Power and energy meter
Contemporary Controls Schneider Electric PowerLogic ION6200 via BASgatewayLX
Schneider Electric PowerLogic ION6200 meters on Modbus, read by a BASgatewayLX.
Also known as: ION6200, PowerLogic ION6200 - Power and energy meter
Contemporary Controls Schneider Electric PowerLogic ION7550 / ION7650 via BASgatewayLX
Schneider Electric PowerLogic ION7550 and ION7650 power quality meters on Modbus, read by a BASgatewayLX.
Also known as: ION7550, ION7650, PowerLogic ION7550, PowerLogic ION7650 - Power and energy meter
Contemporary Controls Schneider Electric PowerLogic PM200 via BASgatewayLX
Schneider Electric PowerLogic PM200-series power meters on Modbus, read by a BASgatewayLX.
Also known as: PM200, PM210, PowerLogic PM200, Square D PM200 - Power and energy meter
Contemporary Controls Schneider Electric PowerLogic PM750 via BASgatewayLX
Schneider Electric PowerLogic PM750 power meters on Modbus, read by a BASgatewayLX.
Also known as: PM750, PM700, PowerLogic PM750 - Power and energy meter
Contemporary Controls Schneider Electric PowerLogic PM800 via BASgatewayLX
Schneider Electric PowerLogic PM800-series power meters on Modbus, read by a BASgatewayLX.
Also known as: PM800, PM810, PM820, PM850, PM870, PowerLogic PM800 - Boiler burner management system
Contemporary Controls Siemens LMV3 burner management via BASgatewayLX
Siemens LMV3 (LMV26/36/37) burner management systems with Modbus, read by a BASgatewayLX.
Also known as: LMV3, LMV36, LMV37, LMV26, Siemens LMV Modbus - Boiler burner management system
Contemporary Controls Siemens LMV5 burner management via BASgatewayLX
Siemens LMV5 (LMV51/52) burner management systems with Modbus through the AZL5 display, read by a BASgatewayLX.
Also known as: LMV5, LMV51, LMV52, Siemens LMV5 Modbus, AZL5 - Boiler burner management interface
Contemporary Controls Siemens SCC TS-1100 touchscreen (LMV3/LMV5/RWF, Modbus RTU) via BASgatewayLX
Boilers with an SCC/Siemens TS-1100 touchscreen fronting LMV3 or LMV5 burner management and RWF40/55 controllers, read over Modbus RTU by a BASgatewayLX.
Also known as: TS-1100, TS1100, SCC TS-1100 touchscreen, LMV RWF touchscreen - Flow meter
Contemporary Controls Sierra Instruments InnovaMass / IM 600-700 series via BASgatewayLX
Sierra Instruments 600/700-series flow meters with Modbus output, read by a BASgatewayLX.
Also known as: IM600, IM700, Sierra 600, Sierra 700, Sierra flow meter Modbus - Flow meter (steam / liquid / gas)
Contemporary Controls Spirax Sarco RIM10 flowmeter via BASgatewayLX
Spirax Sarco RIM10 in-line rotor insertion flowmeters (steam, water, gases) with Modbus, read by a BASgatewayLX.
Also known as: RIM10, RIM 10, Spirax Sarco RIM10 Modbus - Combined heat and power (CHP) module
Contemporary Controls Tecogen InVerde Ultra 100 CHP via BASgatewayLX
Tecogen InVerde Ultra 100 inverter-based CHP modules on Modbus, read by a BASgatewayLX.
Also known as: InVerde Ultra 100, InVerde 100, INV-100, Tecogen CHP Modbus - Room operating unit (thermostat / sensor)
Contemporary Controls Thermokon Thanos room operating unit via BASgatewayLX
Thermokon Thanos touch room operating units with Modbus, read by a BASgatewayLX.
Also known as: Thanos, Thanos SR, Thanos EH, Thermokon Thanos Modbus - Boiler controller
Contemporary Controls U.S. Boiler Company Sage2 combustion controller via BASgatewayLX
U.S. Boiler (Burnham) boilers with the Sage2 combustion controller on Modbus, read by a BASgatewayLX.
Also known as: Sage2, SAGE2.1, US Boiler Sage, Burnham Sage2 - Humidity and temperature transmitter (sensor)
Contemporary Controls Vaisala HUMICAP HMW90 via BASgatewayLX
Vaisala HUMICAP HMW90-series humidity and temperature transmitters with Modbus, read by a BASgatewayLX.
Also known as: HMW90, HMW92, HMW93, Vaisala HMW90 Modbus - Process PID controller
Contemporary Controls Valve Pro VC-88 PID controller via BASgatewayLX
Valve Pro VC-88 digital PID process controllers on Modbus, read by a BASgatewayLX.
Also known as: VC-88, VC88, Valve Pro controller - Power and energy meter
Contemporary Controls Veris E50B1A / E50C2A / E50C3A via BASgatewayLX
Veris Industries E50-series DIN-rail power meters on Modbus, read by a BASgatewayLX.
Also known as: E50B1A, E50C2A, E50C3A, Veris E50, E50 power meter - Power and energy meter
Contemporary Controls Veris H8036 Enercept via BASgatewayLX
Veris Industries H8036 networked power meters (Enercept) on Modbus, read by a BASgatewayLX.
Also known as: H8036, Veris H8036, H8035, Enercept H8036 - Variable frequency drive (HVAC)
Contemporary Controls Yaskawa E7 via BASgatewayLX
Yaskawa E7 HVAC drives on Modbus RTU (MEMOBUS), read by a BASgatewayLX.
Also known as: E7 drive, Yaskawa E7 Modbus, CIMR-E7 - Solar PV inverter
Contemporary Controls Yaskawa Solectria PVI 50-100 kW inverter via BASgatewayLX
Yaskawa Solectria Renewables PVI 50 to 100 kW three-phase string/central inverters on Modbus, read by a BASgatewayLX.
Also known as: PVI 50TL, PVI 60TL, PVI 100KW, Solectria PVI, Yaskawa Solectria inverter Modbus
Source: BASgatewayLX Modbus device profile CleaverBrooks_Falcon_b · CleaverBrooks_Falcon_b_LX.csv. Object names, instances and units are reproduced as published; descriptions are our own.