46 rooftop units, AHUs & DOAS BACnet points lists from 18 manufacturers — AAON, Cambridge Air Solutions, CaptiveAire, Carrier, Daikin Applied, Greenheck, Johnson Controls, Lennox, Melink, Neptronic, Price Industries, RenewAire, Swegon, Systemair, TROX, Trane, Viconics, WaterFurnace. Each one has the full object table, the minimum points an integrator needs, enable and heartbeat notes, and CSV/EDE downloads. Click a column heading to sort.
46 of 46 shown
Unit type
| Type | Download | ||||
|---|---|---|---|---|---|
| AAON | AAON PREHEAT-X ControllerAAON PREHEAT-X controllers that stage and modulate electric (SCR/SSR) preheat on AAON units and air handlers. · G086640 Also known as: PREHEAT-X, PREHEATX, Preheat-X, G086640, AAON preheat controller, Orion PREHEAT-X | Air handler | 28 | 3 | CSVEDE |
| AAON | AAON VCB-X ControllerAAON packaged rooftop units, air handlers, DOAS and water-source units controlled by the Orion VCB-X (OE335-26B-VCBX) unit controller. · OR-VCBX-FIELD-TGD-01X Also known as: VCBX, VCB-X, Orion VCB-X, OE335-26B-VCBX, V28940, WattMaster VCB-X, AAON VCB-X BACnet | Rooftop unitAir handler | 196 | 73 | CSVEDE |
| AAON | AAON VCCX2 ControllerAAON rooftop units, air handlers and DOAS units controlled by the VCCX2 (ASM01698) unit controller. · G115820 Also known as: VCC-X2, VCCX, VCC-X, ASM01698, Orion VCCX2, SS1088 | Rooftop unitAir handler | 534 | 99 | CSVEDE |
| Cambridge Air Solutions | Cambridge Air Solutions BACnet Controller - MAUCambridge Air Solutions direct-fired make-up air and space heating units fitted with the optional BACnet Controller. · Version 4.0.3.0012 Also known as: Cambridge MAU controller, Cambridge BACnet Controller, Cambridge heater BACnet, MAU Technical Manual 4.0.3.0012 | Make-up air | 77 | 42 | CSVEDE |
| CaptiveAire | CaptiveAire DCV Package DDC (Protocessor BACnet)CaptiveAire demand control ventilation packages that run kitchen hood exhaust and supply (make-up air) fans, with the factory BACnet option. Also known as: CaptiveAire DCV, Demand Control Ventilation, DCV Packages Network, Kitchen hood DCV, CASlink, Protocessor, CN0861 | Make-up air | 231 | 10 | CSVEDE |
| CaptiveAire | CaptiveAire MUA Heater DDC (Protocessor BACnet)CaptiveAire make-up air heater units (including direct-fired) with the factory DDC/BMS package. Also known as: CaptiveAire make-up air, Direct fired MUA, Tempered make-up air, DDC Application Guide MUA | Make-up air | 161 | 118 | CSVEDE |
| CaptiveAire | CaptiveAire Paragon RTU / DOAS DDC (Protocessor BACnet)CaptiveAire Paragon HVAC series packaged rooftop units and dedicated outdoor air systems with the factory DDC package. Also known as: Paragon, CaptiveAire DOAS, CaptiveAire RTU, Protocessor, CN0861, RTU DDC Points | Rooftop unitDOAS | 300 | 194 | CSVEDE |
| Carrier | Carrier 48/50K and 48/50V Rooftop (SmartVu PIC 6.1)Carrier 48/50K and 48/50V applied rooftop units (gas heat or electric heat, R-454B) with SmartVu controls on PIC 6.1 hardware. · 48-50-ART-SVU-1T Also known as: SmartVu, PIC 6.1, PIC6.1, 48K, 50K, 48V, 50V, 48/50K, 48/50V, Carrier applied rooftop, 48-50-ART-SVU-1T | Rooftop unit | 715 | 393 | CSVEDE |
| Carrier | Carrier RTU Open v5Carrier packaged rooftop units and heat pumps retrofitted or factory-fitted with the RTU Open controller. · 11-808-697-01 Also known as: RTU Open, OPN-RTU, RTU-Open, 11-808-697-01 | Rooftop unit | 200 | 104 | CSVEDE |
| Daikin Applied | Daikin Applied ADK digital air handler, DSTREAM controls (Daikin Applied Europe)Daikin Applied Europe ADK digital air handling units (D-AHU) with the MicroTech III or MicroTech 4 controller and DSTREAM control software. · D-EIGOC00108-22_05EN Also known as: ADK, D-AHU, Digital AHU, Daikin D-AHU, DSTREAM, D-EIGOC00108-22_05 | Air handler | 431 | 61 | CSVEDE |
| Daikin Applied | Daikin Applied MicroTech 4 Rebel Applied Rooftop Unit ControllerDaikin Rebel Applied (DPSA) packaged rooftop units with the MicroTech 4 unit controller. · ED 19117-3 Also known as: Rebel Applied, DPSA, MicroTech 4 AHU, MT4 AHU, MT4_AHU, ED 19117 | Rooftop unit | 384 | 94 | CSVEDE |
| Daikin Applied | Daikin Applied MicroTech III Applied Rooftop and Self-Contained Unit ControllerRebel (DPS/DPH), Maverick (MPS), RoofPak rooftops and air handlers (RPS, RDT, RFS, RDS, RAH, RPE, RDE) and SWP/SWT self-contained units. · ED 15112-20 Also known as: MicroTech III AHU, RoofPak, Rebel DPS, Maverick MPS, RPS, RDT, RFS, RDS, RAH, RPE, RDE, SWP, SWT, ED 15112 | Rooftop unitAir handler | 294 | 112 | CSVEDE |
| Daikin Applied | Daikin Applied MicroTech PreciseLine Light Air Handler ControllerPreciseLine light commercial air handlers (BCV, BCA, BCH; 600-10,000 CFM) with the MicroTech 4 Lite controller, including R-410A D-Kit and R-32 EV-kit VRV units. · ED 19126-4 Also known as: PreciseLine, MicroTech 4 Lite, MT4 Lite AHU, PL AHU, BCV, BCA, BCH, ED 19126 | Air handler | 310 | 125 | CSVEDE |
| Daikin Applied | Daikin Applied MicroTech Unit Ventilator ControllerDaikin Applied unit ventilators with the MicroTech UV unit controller and its on-board BACnet MS/TP port. · ED 19110-6 Also known as: MicroTech UV, MTUC_UV, Daikin unit ventilator, ED 19110 | Air handler | 187 | 127 | CSVEDE |
| Daikin Applied | Daikin Applied MicroTech Vision / Skyline EC Fan Array ControllerVision (CAH/CAC) and Skyline (OAH/OAC) air handlers with an EC fan array on the MicroTech 4 fan controller (Premium controls option), up to 20 fans. · ED 19122-3 Also known as: Vision, Skyline, MT4_DFA_EC, MT4_DFA, CAH, CAC, OAH, OAC, EC fan array, ED 19122 | Air handler | 146 | 10 | CSVEDE |
| Daikin Applied | Daikin Applied Modular Light (ALB) air handler, EvoLVE controls (Daikin Applied Europe)Daikin Applied Europe Modular Light (ALB) compact air handling units with the MicroTech controller and EvoLVE / Airstream control software. · D-EIGOC00106-26_00EN Also known as: Modular Light, ALB, Daikin Modular Light AHU, EvoLVE, Airstream, D-EIGOC00106-26_00 | Air handler | 81 | 18 | CSVEDE |
| Greenheck | Greenheck Dedicated Outdoor Air Systems (DOAS) - BACnetGreenheck dedicated outdoor air units whose factory controller runs the DOAS_10 program with BACnet licensed. · Document 485940 (DOAS_10.006 Rev 5) Also known as: Greenheck DOAS, DOAS, DOAS_10.006, 485940 | DOAS | 109 | 45 | CSVEDE |
| Greenheck | Greenheck IVE Indoor Energy Recovery Ventilator (BACnet)Greenheck IVE indoor energy recovery ventilators with the factory c.pCO Mini controller. · Document 487690 (IVE_01.002 Rev 1) Also known as: IVE, Greenheck IVE, IVE_01.002, 487690, c.pCO Mini | Energy recovery | 95 | 42 | CSVEDE |
| Johnson Controls | Johnson Controls Premier Rooftop Units 25-50 TonJohnson Controls Premier 25-50 ton R-410A packaged rooftop units (MZVAV or SZVAV) with the Applied Smart Equipment controller. · 5586996-JSG-A-520 Also known as: JCI Premier RTU, Premier 25-50 ton, Applied Smart Equipment controller, Smart Equipment rooftop, 5586996-JSG-A | Rooftop unit | 322 | 115 | CSVEDE |
| Johnson Controls | Johnson Controls TEC3000 Series TEC3630 / TEC3631 Single- or Two-Stage RTU / Heat Pump Thermostat with Economizer (BACnet MS/TP)Single- or two-stage unitary rooftop units and heat-pump RTUs, with or without an economizer, using the networked TEC3630 and TEC3631 thermostats. · LIT-12011956 Also known as: TEC3630, TEC3631, TEC363x, TEC3000 economizer, JCI TEC3000 rooftop thermostat | Rooftop unit | 101 | 73 | CSVEDE |
| Lennox | Lennox CORE LITE Unit ControllerLennox rooftop units built with the CORE LITE Unit Controller, fitted with the add-on BACnet MS/TP plug-in module. · 508727-01 Also known as: CORE Lite, Lennox CORE Lite, CORE LITE BACnet, Lennox_M4, 508727 | Rooftop unit | 62 | 29 | CSVEDE |
| Lennox | Lennox CORE Unit ControllerLennox commercial rooftop units built with the CORE Unit Controller. · 508112-02 Also known as: Lennox CORE, CORE controller, CORE RTU controller, M4 unit controller, A55, Lennox_CORE, 508112 | Rooftop unit | 99 | 38 | CSVEDE |
| Lennox | Lennox Prodigy M3 BACnet ModuleLennox commercial rooftop units that use the Prodigy M3 unit controller. · Corp 1404-L4 (450402) Also known as: M3 BACnet Module, BM2, Prodigy M3, Lennox_M3, Prodigy 2.0 BACnet, 1404-L4 | Rooftop unit | 83 | 33 | CSVEDE |
| Melink | Melink Intelli-Hood IH4 Exhaust Fan / Auxiliary AirflowEach exhaust fan and auxiliary airflow (make-up air fan) VFD run by a Melink Intelli-Hood 4 system. Also known as: Intelli-Hood, IH4, IH4-SC, Melink IH4, Intelli-Hood 4 | Make-up air | 8 | 1 | CSVEDE |
| Melink | Melink Intelli-Hood IH4 Hood ControllerEach Hood Controller (temperature probes and optic smoke sensor) in a Melink Intelli-Hood 4 system. Also known as: Intelli-Hood, IH4, IH4-SC, Melink IH4, Intelli-Hood 4 | Make-up air | 5 | 0 | CSVEDE |
| Melink | Melink Intelli-Hood IH4 System ControllerThe main BACnet device of a Melink Intelli-Hood 4 (IH4-SC) kitchen demand-control ventilation system. Also known as: Intelli-Hood, IH4, IH4-SC, Melink IH4, Intelli-Hood 4 | Make-up air | 20 | 0 | CSVEDE |
| Melink | Melink Intelli-Hood IH4 Virtual Input ModuleVirtual Input Modules of a Melink Intelli-Hood 4 system, which let a BMS drive the system over BACnet. Also known as: Intelli-Hood, IH4, IH4-SC, Melink IH4, Intelli-Hood 4 | Make-up air | 8 | 8 | CSVEDE |
| Melink | Melink Intelli-Hood IH4 Virtual Output ModuleVirtual Output Modules of a Melink Intelli-Hood 4 system, which give a BMS extra status outputs over BACnet. Also known as: Intelli-Hood, IH4, IH4-SC, Melink IH4, Intelli-Hood 4 | Make-up air | 4 | 0 | CSVEDE |
| Neptronic | Neptronic CMU Compact Make-up Air UnitNeptronic CMU compact make-up air units with electric heating, EC fan, damper and optional exhaust fan outputs. · CMU-BACnet Guide-211201 Also known as: CMU, Neptronic CMU | Make-up air | 130 | 76 | CSVEDE |
| Price Industries | Price Industries PRTU Price Rooftop Unit ControllerPackaged single- and multi-stage rooftop units (about 2-30 tons) run by a Price PRTU, alone or polling Price zone controllers. Also known as: PRTU, Price Rooftop Unit Controller, PRTU-STAT | Rooftop unit | 89 | 55 | CSVEDE |
| RenewAire | RenewAire BACnet Fan Control BACNETFC-WRenewAire HE and LE series ERVs, plus EV Premium, EV Premium+, SL75 and SL+ 75 units. · 105802_003_FEB26 Also known as: BACNETFC-W, BACNETFC, RenewAire BACnet Fan Control, RenewAire BACnet fan controller | Energy recovery | 16 | 5 | CSVEDE |
| RenewAire | RenewAire Premium Commercial Controls (ERV & DOAS)RenewAire commercial ERVs and DOAS units (HE-Series, LE-Series and DN-Series) with Premium Commercial Controls version 4.xx (Carel c.pCO Mini controller plus c.pCOe expansion module). · 147641_010_MAY26 Also known as: RenewAire Premium Controls, Premium Commercial Controls, RenewAire DOAS controls, Carel c.pCO Mini, c.pCOe, 147641 | DOASEnergy recovery | 184 | 66 | CSVEDE |
| RenewAire | RenewAire Premium Commercial Controls (Legacy, v3.xx)Older RenewAire commercial ERVs (HE1.5-8X, LE-Series and RD-Series) with Premium Commercial Controls version 3.xx (Carel c.pCO Mini plus c.pCOe expansion module). · 105999_010_D01_JUN25 Also known as: RenewAire Premium Controls legacy, Premium Commercial Controls v3, Carel c.pCO Mini, 105999 | Energy recovery | 137 | 47 | CSVEDE |
| Swegon | Swegon Compact / GOLD LP BACnet IP (PV 2.01+)Swegon COMPACT and GOLD LP air handling units with controller program version 2.01 or later. · GB.BACnet480.100129 Also known as: COMPACT Air, GOLD LP, Compact/GOLD LP, GB.BACnet480.100129, BACnet480 | Air handler | 600 | 401 | CSVEDE |
| Swegon | Swegon GOLD generation E (RX/PX/CX/SD) BACnet IPSwegon GOLD air handling units of generation E (RX, PX, CX and SD versions) running program version 1.10 or later. · GOLD_E_BACnet_150316 Also known as: GOLD E, GOLD RX, GOLD PX, GOLD CX, GOLD SD, IQlogic, GOLD_E_BACnet_150316 | Air handler | 1452 | 525 | CSVEDE |
| Systemair | Systemair Access controller 4.x (4.7) BACnetSystemair air handling units with the Access controller on software 4.x (object files published for 4.7-1-02 build 78). · 4.7-1-02 build 78 Also known as: Systemair Access 4.7, Access 4.7-1-02, Access 4.x, BACnet_Module01_ControllerProgram | Air handler | 1050 | 362 | CSVEDE |
| Systemair | Systemair Access controller 5.x (ControllerProgram) BACnetSystemair air handling units controlled by the Systemair Access controller running application 5.x (published for 5.5-1-01 build 411). · 5.5-1-01 build 411 Also known as: Systemair Access, Access 5.5, Access 5.5-1-01, Systemair Access controller, Access ControllerProgram, EXOL | Air handler | 1201 | 348 | CSVEDE |
| Trane | Trane BCI2-R (ReliaTel)Trane packaged rooftop units with ReliaTel controls (Voyager, Precedent, Odyssey) fitted with the BCI2-R BACnet card. · BAS-SVP053A-EN Also known as: BCI2-R, BCI2R, ReliaTel BACnet interface, BACnet Communication Interface for ReliaTel, BAS-SVP053, Voyager, Precedent, Odyssey | Rooftop unit | 250 | 53 | CSVEDE |
| Trane | Trane Symbio 500 Commercial Self-Contained (SWUD)Trane commercial self-contained (SWUD) units controlled by a Symbio 500. · BAS-PTS038B-EN Also known as: Symbio 500, SWUD, Commercial Self-Contained, CSC, BAS-PTS038 | Self-contained | 356 | 89 | CSVEDE |
| Trane | Trane Symbio 500 Modular Self-Contained (SCWM)Trane modular self-contained (SCWM) units controlled by a Symbio 500. · BAS-PTS037A-EN Also known as: Symbio 500, SCWM, Modular Self-Contained, BAS-PTS037 | Self-contained | 511 | 111 | CSVEDE |
| Trane | Trane Symbio 700 Precedent / AxiomTrane Precedent packaged rooftop units and Axiom rooftop water-source heat pumps with the Symbio 700 controller. · BAS-PTS001C-EN Also known as: Symbio 700, Symbio700, Precedent rooftop, Axiom rooftop WSHP, BAS-PTS001 | Rooftop unit | 639 | 232 | CSVEDE |
| Trane | Trane Symbio 800 IntelliPakTrane IntelliPak large packaged rooftop units running the Symbio 800 controller. · BAS-PTS003C-EN Also known as: Symbio 800, IntelliPak rooftop, IntelliPak with Symbio 800, BAS-PTS003 | Rooftop unitAir handler | 380 | 95 | CSVEDE |
| TROX | TROX X-CUBE Control BACnet data point listTROX X-CUBE central air handling units with the factory X-CUBE Control system. · V003 Also known as: X-CUBE, TROX X-CUBE, X-CUBE Control, BACnet DPL, BACnet EDE XCUBE | Air handler | 743 | 17 | CSVEDE |
| Viconics | Viconics VT8650 Rooftop Unit and Heat Pump ControllerViconics VT8000-series VT8650 room controllers for packaged rooftop units and heat pumps (up to 2 heating and 2 cooling stages), with economizer and indoor air quality options. · 028-0437-07_IG-VT8650-BNET_A4_EN (Version 7) Also known as: VT8650, Viconics VT8650, VT8000 VT8650, Schneider Electric VT8650 | Rooftop unit | 456 | 280 | CSVEDE |
| WaterFurnace | WaterFurnace Aurora UPC, Dual Compressor Rooftop Unit with EconomizerWaterFurnace dual-compressor water-source rooftop units with an economizer, Aurora controls and the Aurora UPC. · PL1250EW Also known as: PL1250EW, Aurora UPC rooftop economizer, Aurora Universal Protocol Converter | Rooftop unit | 392 | 171 | CSVEDE |
| WaterFurnace | WaterFurnace Aurora UPC, Single Compressor Rooftop Unit with EconomizerWaterFurnace single-compressor water-source rooftop units with an economizer, Aurora controls and the Aurora UPC. · PL1250EW Also known as: PL1250EW, Aurora UPC rooftop economizer, Aurora Universal Protocol Converter | Rooftop unit | 284 | 145 | CSVEDE |