21 vRF & split air conditioners BACnet points lists from 11 manufacturers — CoolAutomation, Daikin, Fujitsu, Gree, Intesis, Lennox, Mitsubishi Electric, Samsung, Systemair, Toshiba, Trane. Each one has the full object table, the minimum points an integrator needs, enable and heartbeat notes, and CSV/EDE downloads. Click a column heading to sort.

21 of 21 shown
Unit type
Type Download
CoolAutomationCoolAutomation CoolMasterNet BACnet (indoor unit objects)Indoor units of VRF and split systems connected to a CoolMasterNet or CooLink gateway (Daikin, Mitsubishi Electric, LG, Samsung, Gree and other supported brands). Also known as: CoolMasterNet, CooLinkNet, CooLinkHub, CooLinkBridge, CoolAutomation BACnet, LG VRF BACnet gateway, Daikin VRV BACnet gateway, Mitsubishi Electric BACnet gateway, Samsung BACnet gateway, Gree GMV BACnet gatewayVRF / VRVSplit ACGateway / interface1612CSVEDE
CoolAutomationCoolAutomation CoolMasterNet LG VRF outdoor unit (PRO) objectsLG VRF outdoor units read through a CoolAutomation gateway with PRO (service data) functionality. Also known as: LG VRF BACnet, LG BACnet points list, LG outdoor unit BACnet, CoolMasterNet LGVRF / VRVGateway / interface680CSVEDE
DaikinDaikin DMS502B71 Interface for use in BACnetDaikin VRV and ductless indoor units and ERV (VAM) units on up to four DIII-Net lines (256 groups). · EDUS72-749C Also known as: DMS502B71, DAM411B51, D-BACS, Daikin VRV BACnet interface, BACnet Interface, EDUS72-749VRF / VRVGateway / interface3415CSVEDE
DaikinDaikin intelligent Touch Manager (iTM) BACnet Server Gateway DCM014A51 - Indoor Unit and System ObjectsVRV and ductless indoor unit groups managed by a Daikin intelligent Touch Manager with the DCM014A51 BACnet server option. · DG_DCM014A51_02-19 Also known as: DCM014A51, iTM BACnet, intelligent Touch Manager, DCM601A71, DCM601B71, iTM BACnet Server GatewayVRF / VRVGateway / interface4124CSVEDE
DaikinDaikin intelligent Touch Manager (iTM) BACnet Server Gateway DCM014A51 - Outdoor Unit ObjectsVRV outdoor units (main, sub-1 and sub-2 modules) monitored through an iTM with the DCM014A51 BACnet server option. · DG_DCM014A51_02-19 Also known as: DCM014A51, iTM BACnet outdoor unit, intelligent Touch Manager, DCM601A71, DCM601B71VRF / VRVGateway / interface750CSVEDE
FujitsuFujitsu UTY-VBGX BACnet Gateway for VRFFujitsu General Airstage V-II / J-II / VR-II VRF indoor and outdoor units on the VRF network. Also known as: UTY-VBGX, UTYVBGX, BACnet Gateway for VRF System, Fujitsu General BACnet gatewayVRF / VRVGateway / interface5525CSVEDE
GreeGree GMS BACnet Converter (GMS GW) - M/W/P/X series with DWUNIGree M, W, P and X series split indoor units with a DWUNI wired controller connected to a GMS GW 1 or GMS GW 12. · 1.1 Also known as: GMS GW 1, GMS GW 12, GMVGMSGW, DWUNI, Gree Multi BACnetSplit ACGateway / interface2319CSVEDE
GreeGree GMS BACnet Converter (GMS GW) - R seriesGree R-series split indoor units (e.g. Vireo, Livo, Sapphire, Multi) connected to a GMS GW 1 or GMS GW 12. · 1.1 Also known as: GMS GW 1, GMS GW 12, GMVGMSGW, Gree Mini Split BACnet Converter, CoolAutomation Gree gatewaySplit ACGateway / interface3221CSVEDE
IntesisIntesis INBACHIT016O000 / INBACHIT064O000 (Hitachi VRF H-Link BACnet server)Hitachi VRF systems on the H-Link (TB2) bus: up to 16 (INBACHIT016O000) or 64 (INBACHIT064O000) indoor units. Also known as: Hitachi VRF BACnet gateway, Hitachi H-Link BACnet, Hitachi BACnet points list, HI-AC-BAC-16, HI-AC-BAC-64, INBACHIT016O000, Intesis BACnet Server Hitachi VRFVRF / VRVGateway / interface5116CSVEDE
IntesisIntesis INBACPAN016O000 / 064O000 / 128O000 (Panasonic VRF P-Link BACnet server)Panasonic VRF (ECOi and similar) systems on one or two P-Link lines, up to 128 indoor units depending on model. Also known as: Panasonic VRF BACnet gateway, Panasonic P-Link BACnet, Panasonic BACnet points list, PA-AC-BAC-16, PA-AC-BAC-64, PA-AC-BAC-128, INBACPAN016O000, INBACPAN128O000, Intesis BACnet Server Panasonic VRFVRF / VRVGateway / interface5520CSVEDE
IntesisIntesis INBACSAM004O000 / 008O000 / 016O000 / 064O000 (Samsung NASA BACnet server)Samsung air conditioners and heat pumps on the NASA R1/R2 bus, from 4 to 64 indoor units depending on model. Also known as: Samsung BACnet gateway, Samsung NASA BACnet, Samsung DVM BACnet, Samsung BACnet points list, INBACSAM016O000, Intesis BACnet Server Samsung NASAVRF / VRVGateway / interface5420CSVEDE
LennoxLennox VRF BACnet Gateway V0CTRL95P-3Lennox VRF P3 outdoor and indoor units in VRB and VPB systems. · 507951-02 Also known as: V0CTRL95P-3, V0CTRL95P, Lennox VRF BACnet gateway, VRB BACnet gateway, VPB BACnet gateway, 507951VRF / VRVGateway / interface4213CSVEDE
Mitsubishi ElectricMitsubishi Electric AE-C400 / EW-C50 BACnet (BACS-AP50)CITY MULTI VRF indoor unit groups, Lossnay, OA processing units, Air To Water and chiller units managed by an AE-C400 or EW-C50. · WT10808X04 Also known as: AE-C400, AE-C400E, EW-C50, EW-C50E, BACS-AP50, BACS-AP50E, AE-C/EW-C BACnetVRF / VRVCentral controller7128CSVEDE
Mitsubishi ElectricMitsubishi Electric BAC-HD150 BM AdapterCITY MULTI VRF indoor unit groups, Lossnay, and Air To Water (PWFY) units on M-NET, up to 50 groups. · WT05542X04 Also known as: BAC-HD150, BAC-HD/150, BACHD150, BM ADAPTER, CMCN BACnet points list, MEAPP0002VRF / VRVGateway / interface3119CSVEDE
Mitsubishi ElectricMitsubishi Electric PAC-YG31CDA BACnet InterfaceCITY MULTI indoor unit groups managed by up to ten G-50A central controllers. · WT04221X03 Also known as: PAC-YG31CDA, G-50A BACnet, BACnet Interface for G-50AVRF / VRVGateway / interface2211CSVEDE
Mitsubishi ElectricMitsubishi Electric Procon BAC-IP/50CITY MULTI indoor units, Lossnay/OA units and heat-pump boilers connected to one G-50 central controller (up to 50 units). Also known as: BAC-IP/50, BACIP50, Procon BAC IP 50VRF / VRVGateway / interface2510CSVEDE
SamsungSamsung DMS2.5 BACnet Gateway (MIM-B17BN)Samsung DVM VRF and NASA-protocol indoor units, AHU kits, EHS/hydro units, ERVs, DVM chillers, outdoor units and DMS2.5 I/O behind a DMS2.5 controller. · DB68-06095A-05 Also known as: MIM-B17BN, MIM-B17BNDZ, MIM-B17, DMS2.5, DMS 2.5, MIM-D01AN, DMS BACnet gatewayVRF / VRVGateway / interface174104CSVEDE
SystemairSystemair SYS GW IMS BAC(A) VRF BACnet gatewaySystemair SYSVRF indoor units, outdoor units and high-temperature hydro modules (HTHM) on the outdoor unit X/Y/E bus. Also known as: SYS GW IMS BAC(A), SYS GW IMS BAC, IMMP-BAC(A), IMMP-BAC, Systemair VRF BACnet gateway, SYS GW gatewayVRF / VRVGateway / interface8521CSVEDE
ToshibaToshiba BN interface BMS-IFBN1281UToshiba Carrier VRF indoor units, air-to-water heat pumps and RAC interfaces on TU2C-LINK (Uh line) or TCC-LINK. · A10-2301-3 Also known as: BMS-IFBN1281U-E, BMS-IFBN1281U-TR, Toshiba BACnet interface, Toshiba Carrier BN interface, TU2C-LINK BACnetVRF / VRVGateway / interface6826CSVEDE
TraneTrane Symbio 700 OdysseyTrane Odyssey split systems controlled by a Symbio 700. · BAS-PTS005B-EN Also known as: Symbio 700, Odyssey split system, BAS-PTS005Split AC389136CSVEDE
TraneTrane Symbio 800 IntelliCore Split System (RAUK)Trane IntelliCore split systems (RAUK) controlled by a Symbio 800. · BAS-PTS036A-EN Also known as: IntelliCore, RAUK, IntelliCore split system, Symbio 800, BAS-PTS036Split AC13616CSVEDE