Electric power meter via BACnet gateway · BACnet points list
Cleaver-Brooks Shark 200 power meter profile (ProtoNode) BACnet points list
Updated 7 November 2026Unofficial source
A read-only ProtoNode profile for the Shark 200 meter: phase and line voltages, phase and neutral currents, kW, kVAR, kVA, power factor, frequency, energy totals, demand averages and maxima, and voltage and current THD.
This page lists 50 BACnet objects for the Cleaver-Brooks Shark 200 power meter profile (ProtoNode) — 0 of them writable — with each object’s type, instance number, name, engineering units and access. It is re-typed from a copy of Cleaver-Brooks’s documentation hosted by watmfg.com, not by Cleaver-Brooks itself, so treat it as unofficial.
- Manufacturer
- Cleaver-Brooks
- Model
- Shark 200 power meter profile (ProtoNode)
- Equipment
- Electric power meter via BACnet gateway
- Equipment type
- Thermostats, sensors & meters
- BACnet objects
- 50 (0 writable)
- Transport
- BACnet MS/TP, BACnet IP
- Firmware
- Not stated
- Default device instance
- 50000 + Modbus Node-ID
- Also known as
- Shark 200, Electro Industries Shark 200, ProtoNode RER, 750-426
- Source document
- Cloud Enabled ProtoNode Gateway Startup Guide (RER/LER) for interfacing Cleaver-Brooks products · 750-426 · rev. 03/2018 (unofficial copy, hosted by watmfg.com)
Reference only, provided as-is: verify against Cleaver-Brooks’s current documentation and the live device before use. Not official Cleaver-Brooks information. Terms of use.
BMS integration notes: Cleaver-Brooks Shark 200 power meter profile (ProtoNode)
Read-only. Map voltage, current, total kW, power factor, frequency and energy.
Minimum points to map
The short list most integrators start with — enough to run the unit from a BMS. Map more as the job needs.
| Object | Name | Why | Access |
|---|---|---|---|
| AI 1 | Volts A-N | Volts A-N | Read |
| AI 7 | Amps A | Amps A | Read |
| AI 10 | Watts 3-Ph total | Total watts, 3-phase | Read |
| AI 13 | Power Factor 3-Ph total | Power factor, 3-phase | Read |
| AI 14 | Frequency | Frequency | Read |
| AI 29 | W-hours Delivered | Watt-hours delivered | Read |
Network setup
- BACnet Device Instance = the controller's Modbus Node-ID + Node_Offset (default 50,000), so Node-ID 1 = 50001. Change Node_Offset in the ProtoNode web configurator to pick other instances.
- The ProtoNode RER does BACnet MS/TP or BACnet IP, selected on its S bank DIP switches.
- BACnet MS/TP: one MAC address (1-127) for the whole ProtoNode on the A bank DIP switches; baud on B0-B3 (38400 factory default).
- BACnet IP: default ProtoNode address 192.168.1.24; change it in the web configurator.
Cleaver-Brooks Shark 200 power meter profile (ProtoNode) BACnet objects
Type: AI, AO, AV, BI, BO, BV, MI/MO/MV (multi-state) · Access: Read read-only, Write writable, Command writable with a priority array.
| Description | States | |||||
|---|---|---|---|---|---|---|
| AImin | 1 | Volts A-N | Modbus 41000 | Read | ||
| AI | 2 | Volts B-N | Modbus 41002 | Read | ||
| AI | 3 | Volts C-N | Modbus 41004 | Read | ||
| AI | 4 | Volts A-B | Modbus 41006 | Read | ||
| AI | 5 | Volts B-C | Modbus 41008 | Read | ||
| AI | 6 | Volts C-A | Modbus 41010 | Read | ||
| AImin | 7 | Amps A | Modbus 41012 | Read | ||
| AI | 8 | Amps B | Modbus 41014 | Read | ||
| AI | 9 | Amps C | Modbus 41016 | Read | ||
| AImin | 10 | Watts 3-Ph total | Modbus 41018 | Read | ||
| AI | 11 | VARs 3-Ph total | Modbus 41020 | Read | ||
| AI | 12 | VAs 3-Ph total | Modbus 41022 | Read | ||
| AImin | 13 | Power Factor 3-Ph total | Modbus 41024 | Read | ||
| AImin | 14 | Frequency | Modbus 41026 | Read | ||
| AI | 15 | Neutral Current | Modbus 41028 | Read | ||
| AI | 16 | Watts Phase A | Modbus 41030 | Read | ||
| AI | 17 | Watts Phase B | Modbus 41032 | Read | ||
| AI | 18 | Watts Phase C | Modbus 41034 | Read | ||
| AI | 19 | VARs Phase A | Modbus 41036 | Read | ||
| AI | 20 | VARs Phase B | Modbus 41038 | Read | ||
| AI | 21 | VARs Phase C | Modbus 41040 | Read | ||
| AI | 22 | VAs Phase A | Modbus 41042 | Read | ||
| AI | 23 | VAs Phase B | Modbus 41044 | Read | ||
| AI | 24 | VAs Phase C | Modbus 41046 | Read | ||
| AI | 25 | Power Factor Phase A | Modbus 41048 | Read | ||
| AI | 26 | Power Factor Phase B | Modbus 41050 | Read | ||
| AI | 27 | Power Factor Phase C | Modbus 41052 | Read | ||
| AI | 28 | W-hours Received | Modbus 41500 | Read | ||
| AImin | 29 | W-hours Delivered | Modbus 41502 | Read | ||
| AI | 30 | W-hours Net | Modbus 41504 | Read | ||
| AI | 31 | W-hours Total | Modbus 41506 | Read | ||
| AI | 32 | VAR-hours Positive | Modbus 41508 | Read | ||
| AI | 33 | VAR-hours Negative | Modbus 41510 | Read | ||
| AI | 34 | VAR-hours Net | Modbus 41512 | Read | ||
| AI | 35 | VAR-hours Total | Modbus 41514 | Read | ||
| AI | 36 | Amps A Avg | Modbus 42000 | Read | ||
| AI | 37 | Amps B Avg | Modbus 42002 | Read | ||
| AI | 38 | Amps C Avg | Modbus 42004 | Read | ||
| AI | 39 | Positive Watts 3-Ph Avg | Modbus 42006 | Read | ||
| AI | 40 | Positive VARs 3-Ph Avg | Modbus 42008 | Read | ||
| AI | 41 | Negative Watts 3-Ph Avg | Modbus 42010 | Read | ||
| AI | 42 | Negative VARs 3-Ph Avg | Modbus 42012 | Read | ||
| AI | 43 | VAs 3-Ph Avg | Modbus 42014 | Read | ||
| AI | 44 | Positive PF 3-Ph Avg | Modbus 42016 | Read | ||
| AI | 45 | Negative PF 3-PF Avg | Modbus 42018 | Read | ||
| AI | 46 | VA-hours Total | Modbus 43048 | Read | ||
| AI | 51 | Positive Watts 3-Ph Max Avg Demand | Modbus 49018 | Read | ||
| AI | 52 | Positive VARs 3-Ph Max Avg Demand | Modbus 49020 | Read | ||
| AI | 53 | Negative Watts 3-Ph Max Avg Demand | Modbus 49022 | Read | ||
| AI | 54 | Negative VARs 3-Ph Max Avg Demand | Modbus 49024 | Read |
No points match these filters.
Object ID lookup: Cleaver-Brooks Shark 200 power meter profile point IDs by name
AI1Volts A-NAI2Volts B-NAI3Volts C-NAI4Volts A-BAI5Volts B-CAI6Volts C-AAI7Amps AAI8Amps BAI9Amps CAI10Watts 3-Ph totalAI11VARs 3-Ph totalAI12VAs 3-Ph totalAI13Power Factor 3-Ph totalAI14FrequencyAI15Neutral CurrentAI16Watts Phase AAI17Watts Phase BAI18Watts Phase CAI19VARs Phase AAI20VARs Phase BAI21VARs Phase CAI22VAs Phase AAI23VAs Phase BAI24VAs Phase CAI25Power Factor Phase AAI26Power Factor Phase BAI27Power Factor Phase CAI28W-hours ReceivedAI29W-hours DeliveredAI30W-hours NetAI31W-hours TotalAI32VAR-hours PositiveAI33VAR-hours NegativeAI34VAR-hours NetAI35VAR-hours TotalAI36Amps A AvgAI37Amps B AvgAI38Amps C AvgAI39Positive Watts 3-Ph AvgAI40Positive VARs 3-Ph AvgAI41Negative Watts 3-Ph AvgAI42Negative VARs 3-Ph AvgAI43VAs 3-Ph AvgAI44Positive PF 3-Ph AvgAI45Negative PF 3-PF AvgAI46VA-hours TotalAI51Positive Watts 3-Ph Max Avg DemandAI52Positive VARs 3-Ph Max Avg DemandAI53Negative Watts 3-Ph Max Avg DemandAI54Negative VARs 3-Ph Max Avg Demand
Integration notes
- Each Cleaver-Brooks controller on the ProtoNode is its own BACnet device; the object instances below are the same on every device.
- The profile has only AI and BI objects and the guide marks none as write points, so all are read-only.
- The guide gives no engineering units or state texts; units appear only where the object name carries them (DEG F / DEG C).
- Where a description is filled in, it gives the register from the guide's Modbus column.
Check it against the live device. A points list tells you what the controller can expose; the unit in front of you may differ by firmware or installed options. This list is provided as-is for reference only and may contain mistakes — confirming it before you write, map or commission anything is up to you (terms). Easy BACnet scans a network for BACnet IP devices from an Android phone, reads every object on the Shark 200 power meter profile (ProtoNode) and exports what it actually has to Excel — free. New to BACnet? Start with what a BACnet points list is and what the object types mean.
Questions about the Cleaver-Brooks Shark 200 power meter profile (ProtoNode)
How many BACnet points does the Cleaver-Brooks Shark 200 power meter profile (ProtoNode) have?
This list has 50 BACnet objects: 50 analog inputs. The exact set on a given unit depends on its firmware, installed options and configuration.
Which Cleaver-Brooks Shark 200 power meter profile (ProtoNode) BACnet points are writable?
None of the listed objects are marked writable in the source documentation.
Where is the official Cleaver-Brooks Shark 200 power meter profile (ProtoNode) BACnet documentation?
Cleaver-Brooks does not publish it on its own website. This list comes from Cloud Enabled ProtoNode Gateway Startup Guide (RER/LER) for interfacing Cleaver-Brooks products (750-426), revision 03/2018, a copy hosted by watmfg.com at https://watmfg.com/watmfg23082016/wp-content/uploads/2016/09/750-426-ProtoNode-Cloud.pdf. Ask Cleaver-Brooks or its representative for the current revision.
What are the minimum BACnet points to integrate the Cleaver-Brooks Shark 200 power meter profile (ProtoNode)?
Start with AI 1 Volts A-N (Volts A-N); AI 7 Amps A (Amps A); AI 10 Watts 3-Ph total (Total watts, 3-phase); AI 13 Power Factor 3-Ph total (Power factor, 3-phase); AI 14 Frequency (Frequency); AI 29 W-hours Delivered (Watt-hours delivered).
How do I check these points on the real Shark 200 power meter profile (ProtoNode)?
Scan the network with a BACnet IP browser such as Easy BACnet, open the device and compare its object list with this table. Anything missing is usually an option that isn't installed or a point that is disabled in the controller's configuration.
More Cleaver-Brooks BACnet points lists
- Boiler feedwater deaerator and surge tank controller via BACnet gateway
Cleaver-Brooks ADAC 1000 deaerator / surge tank control (ProtoNode, EtherNet/IP)
Cleaver-Brooks deaerator and surge tank packages with the ADAC 1000 PLC control, read through a ProtoNode RER gateway over EtherNet/IP.
Also known as: ADAC 1000, ADAC_1000, ProtoNode RER, 750-426 - Boiler feedwater deaerator and surge tank controller via BACnet gateway
Cleaver-Brooks ADAC deaerator / surge tank control (ProtoNode)
Cleaver-Brooks deaerator and surge tank packages with the ADAC control, read through a ProtoNode RER gateway.
Also known as: ADAC, CB deaerator control, ProtoNode RER, 750-426 - Boiler flame safeguard via BACnet gateway
Cleaver-Brooks CB120 flame safeguard (ProtoNode)
Cleaver-Brooks boilers with the CB120 flame safeguard, read through a ProtoNode RER gateway.
Also known as: CB120, CB 120, ProtoNode RER, 750-426 - Boiler flame safeguard via BACnet gateway
Cleaver-Brooks CB780 flame safeguard with expanded annunciator (ProtoNode)
Cleaver-Brooks boilers with the CB780 burner management control and expanded annunciator, read through a ProtoNode RER gateway.
Also known as: CB780, CB 780, CB780E, ProtoNode RER, 750-426 - Hot water boiler control via BACnet gateway
Cleaver-Brooks Falcon Hydronic boiler control (ProtoNode)
Cleaver-Brooks hot water boilers with the Falcon hydronic burner control, read through a ProtoNode RER gateway.
Also known as: Falcon Hydronic, ClearFire Falcon, CB Falcon, ProtoNode RER, 750-426 - Steam boiler control via BACnet gateway
Cleaver-Brooks Falcon Steam boiler control (ProtoNode)
Cleaver-Brooks steam boilers with the Falcon steam burner control, read through a ProtoNode RER gateway.
Also known as: Falcon Steam, CB Falcon steam, ProtoNode RER, 750-426 - Boiler flame safeguard and fuel-air ratio control via BACnet gateway
Cleaver-Brooks FARC with CB780 / CB783 burner control (ProtoNode)
Cleaver-Brooks boilers with a CB780/CB783 burner control and FARC fuel-air ratio control, read through a ProtoNode RER gateway.
Also known as: FARC, CB 780/783, CB783, ProtoNode RER, 750-426 - Steam or hot water boiler control via BACnet gateway
Cleaver-Brooks Hawk 1000 boiler control (ProtoNode)
Cleaver-Brooks boilers with the Hawk 1000 PLC boiler control, read through a ProtoNode RER gateway.
Also known as: Hawk 1000, CB Hawk 1000, ProtoNode RER, 750-426 - Steam or hot water boiler control via BACnet gateway
Cleaver-Brooks Hawk 2000 boiler control (ProtoNode)
Cleaver-Brooks boilers with the Hawk 2000 control, read through a ProtoNode RER gateway.
Also known as: Hawk 2000, CB Hawk 2000, ProtoNode RER, 750-426 - Steam or hot water boiler control via BACnet gateway
Cleaver-Brooks Hawk 4000 boiler control (ProtoNode)
Cleaver-Brooks boilers with the Hawk 4000 PLC boiler control, read through a ProtoNode RER gateway.
Also known as: Hawk 4000, CB Hawk 4000, ProtoNode RER, 750-426 - Steam or hot water boiler control via BACnet gateway
Cleaver-Brooks Hawk 4000 V2 boiler control (ProtoNode)
Cleaver-Brooks boilers with the HAWK 4000 V2 PLC boiler control, read through a ProtoNode RER gateway.
Also known as: HAWK 4000 V2, CB HAWK 4000 V2, HAWK_4000_V2, ProtoNode RER, 750-426 - Steam or hot water boiler control via BACnet gateway
Cleaver-Brooks Hawk 4500 boiler control (ProtoNode, EtherNet/IP)
Cleaver-Brooks boilers with the Hawk 4500 PLC boiler control, read through a ProtoNode RER gateway over EtherNet/IP.
Also known as: Hawk 4500, CB Hawk 4500, ProtoNode RER, 750-426 - Steam boiler control via BACnet gateway
Cleaver-Brooks Hawk 5000 boiler control (ProtoNode)
Cleaver-Brooks steam boilers with the Hawk 5000 control, read through a ProtoNode RER gateway.
Also known as: Hawk 5000, CB Hawk 5000, ProtoNode RER, 750-426 - Steam or hot water boiler control via BACnet gateway
Cleaver-Brooks Hawk ICS boiler control (ProtoNode)
Cleaver-Brooks boilers with the Hawk ICS control, read through a ProtoNode RER gateway.
Also known as: Hawk ICS, CB ICS, ProtoNode RER, 750-426 - Boiler lead/lag master panel via BACnet gateway
Cleaver-Brooks Hawk Master Panel lead/lag (ProtoNode)
Cleaver-Brooks Hawk Master Panels sequencing up to eight Hawk boilers (A-H), read through a ProtoNode RER gateway.
Also known as: Hawk Master Panel, Hawk Master, CB Master Panel, ProtoNode RER, 750-426 - Boiler interface module via BACnet gateway
Cleaver-Brooks HSC Boiler Interface Module (ProtoNode)
Cleaver-Brooks HSC boiler interface modules (one boiler each), read through a ProtoNode RER gateway.
Also known as: Boiler Interface Module, HSC Boiler Interface, BIM, ProtoNode RER, 750-426 - Multi-boiler sequencer (hot water boiler plant) via BACnet gateway
Cleaver-Brooks HSC Hydronic System Controller (ProtoNode)
Cleaver-Brooks HSC panels sequencing up to 10 condensing and 10 non-condensing boilers, read through a ProtoNode RER gateway.
Also known as: HSC, Hydronic System Controller, CB HSC, ProtoNode RER, 750-426 - Pump interface module (boiler plant pumps) via BACnet gateway
Cleaver-Brooks HSC Pump Interface Module (ProtoNode)
Cleaver-Brooks HSC pump interface modules (up to four system pumps), read through a ProtoNode RER gateway.
Also known as: Pump Interface Module, HSC Pump Interface, ProtoNode RER, 750-426 - Boiler water level controller via BACnet gateway
Cleaver-Brooks LCS Level Control System (ProtoNode)
Cleaver-Brooks LCS water level controllers (one or two tanks), read through a ProtoNode RER gateway.
Also known as: LCS, Level Control System, ProtoNode RER, 750-426 - Boiler feed pump controller via BACnet gateway
Cleaver-Brooks PCS Pump Control System (ProtoNode)
Cleaver-Brooks PCS pump controllers (up to four pumps on header pressure or tank level), read through a ProtoNode RER gateway.
Also known as: PCS, Pump Control System, ProtoNode RER, 750-426 - Electric power meter via BACnet gateway
Cleaver-Brooks Shark 100 power meter profile (ProtoNode)
Shark 100 power meters supplied on Cleaver-Brooks equipment, read through a ProtoNode RER gateway.
Also known as: Shark 100, Electro Industries Shark 100, ProtoNode RER, 750-426 - Process loop controller via BACnet gateway
Cleaver-Brooks UDC 2500 loop controller profile (ProtoNode)
Honeywell UDC 2500 loop controllers supplied on Cleaver-Brooks equipment, read through a ProtoNode RER gateway.
Also known as: UDC 2500, UDC2500, Honeywell UDC 2500, ProtoNode RER, 750-426
Source: Cloud Enabled ProtoNode Gateway Startup Guide (RER/LER) for interfacing Cleaver-Brooks products · 750-426 · rev. 03/2018. Object names, instances and units are reproduced as published; descriptions are our own.