Easy BACnet
  1. Home
  2. BACnet points lists
  3. VFDs & pumps

Equipment type

VFDs & pumps BACnet points lists

Updated 28 October 2026

21 vFDs & pumps BACnet points lists from 10 manufacturers — ABB, Bell & Gossett, Danfoss, Delta Electronics, Grundfos, Lenze, Schneider Electric, Siemens, WEG, Yaskawa. Each one has the full object table, the minimum points an integrator needs, enable and heartbeat notes, and CSV/EDE downloads. Click a column heading to sort.

21 of 21 shown
Unit type
Type Download
ABBABB ACH550 HVAC drive (embedded BACnet MS/TP)ABB ACH550 HVAC drives using the built-in RS-485 port with native BACnet MS/TP. Also known as: ACH550, ACH550-01, ACH550-UH, ACH550 E-ClipseDrive7228CSVEDE
ABBABB ACH580 HVAC drive (embedded BACnet MS/TP)ABB ACH580 HVAC drives using the built-in EFB port with protocol set to BACnet MS/TP. · 3AXD50000027537 Rev J Also known as: ACH580, ACH580-01, ACH580-31, ACH580 E-Clipse, ACH580 HVAC control program, 3AXD50000027537Drive12946CSVEDE
Bell & GossettBell & Gossett FC-102 Embedded BACnet (pump drive)Bell & Gossett pump packages that use the FC-102 HVAC drive with its built-in BACnet MS/TP (firmware 3.90 and above). · BGBACNET Also known as: FC-102, FC102, VLT HVAC Drive FC 102DrivePump12562CSVEDE
Bell & GossettBell & Gossett MCA 109 Advanced BACnet Option (FC-102)Bell & Gossett pump packages with an FC-102 drive fitted with the MCA 109 Advanced BACnet option card (firmware 3.90 and above). · BGBACNET Also known as: MCA109, MCA 109, FC-102 BACnet option, VLT BACnet optionDrivePumpOption card / module29781CSVEDE
Bell & GossettBell & Gossett Technologic Constant Speed Pump ControllerBell & Gossett Technologic constant speed pumping systems for up to six pumps, with the BACnet MS/TP interface. · Technologic Constant Speed Controller MSTP PIC Ver 2.2 Also known as: Technologic CS, Technologic constant speed, B&G Technologic, ITT TechnologicPump609CSVEDE
DanfossDanfoss VLT AQUA Drive FC 202 with BACnet/IP MCA 125Danfoss VLT AQUA Drive FC 202 fitted with the MCA 125 BACnet/IP option card. · AU361182716349en-000201 (130R0673) Also known as: FC 202, FC202, VLT AQUA Drive, MCA 125, MCA125, 134B1586, VLT BACnet/IPDrivePump250117CSVEDE
DanfossDanfoss VLT HVAC Drive FC 102 with BACnet/IP MCA 125Danfoss VLT HVAC Drive FC 102 fitted with the MCA 125 BACnet/IP option card. · AU361182716349en-000201 (130R0673) Also known as: FC 102, FC102, VLT HVAC Drive, MCA 125, MCA125, 134B1586, VLT BACnet/IPDrive250132CSVEDE
Delta ElectronicsDelta Electronics VFD-CP2000 (embedded BACnet MS/TP)Delta Electronics VFD-CP2000 AC motor drives using the built-in RS-485 port as BACnet MS/TP. Also known as: CP2000, VFD-CP2000, Delta CP2000, Delta VFD CP2000Drive10143CSVEDE
GrundfosGrundfos CIM 300 / CIM 500 BACnet (pumps)Grundfos MAGNA3, E-pumps (MGE motors, TPE etc.) and CUE drives fitted with a CIM/CIU 300 (BACnet MS/TP) or CIM/CIU 500 (BACnet IP) module. · 97572650 Also known as: CIM 300, CIU 300, CIM 500, CIU 500, CIM300, MAGNA3, TPE, MGE, CUE, E-pumpsPumpOption card / module10521CSVEDE
GrundfosGrundfos CIM 500 BACnet IP (booster systems)Grundfos Hydro MPC / Control MPC (CU 35X), Hydro Multi-E and Hydro Multi-B (CU 323) booster systems fitted with a CIM 500 (or CIU 500) BACnet IP module. Also known as: CIM 500, CIU 500, CIM500, Hydro MPC, Hydro Multi-E, Hydro Multi-B, Control MPC, CU 35X, CU 323PumpOption card / module17427CSVEDE
LenzeLenze i500 inverter (BACnet MS/TP)Lenze i500 series inverters (model I51AExxxx10xxxxxxS) with the BACnet MS/TP network option, firmware V01.04. · PICS V01.04 Also known as: i500, Lenze i500, i510, i550, I51AE, Lenze i500 BACnetDrive7734CSVEDE
Schneider ElectricSchneider Electric Altivar 212 (embedded BACnet MS/TP)Schneider Electric Altivar 212 HVAC fan and pump drives using the built-in open-style RS-485 terminals with F829 set to BACnet. · S1A53845 (04) Also known as: ATV212, ATV 212, Altivar 212, ATV212H, ATV212W, S1A53845Drive4820CSVEDE
Schneider ElectricSchneider Electric Altivar Process ATV600 (BACnet MS/TP)Schneider Electric Altivar Process ATV630, ATV650, ATV660 and ATV690 drives on BACnet MS/TP. Also known as: ATV600, ATV630, ATV650, ATV660, ATV690, Altivar Process, Altivar 600, ATV6xxDrive7429CSVEDE
SiemensSiemens BT300 HVAC drive (BACnet)Siemens Building Technologies BT300 HVAC variable frequency drives, all voltage and power ranges, BACnet firmware 1.1. Also known as: BT300, Siemens BT300, BT300 VFD, BT300 frequency converter, BT300 HVAC driveDrive13343CSVEDE
SiemensSiemens SINAMICS G120 CU230P-2 HVAC (BACnet MS/TP)SINAMICS G120 / G120P inverters with the CU230P-2 HVAC control unit using its RS-485 port for BACnet MS/TP. · A5E02430659B AB Also known as: G120P, SINAMICS G120P, CU230P-2, CU230P-2 HVAC, 6SL3243-0BB30-1HA3, A5E02430659BDrive7321CSVEDE
WEGWEG CFW503 (BACnet MS/TP)WEG CFW503 frequency inverters using BACnet MS/TP on the standard or plug-in RS-485 port. · 10012735607 Rev. 00 Also known as: CFW503, WEG CFW503, CFW503 BACnet, 10012735607Drive7741CSVEDE
WEGWEG CFW701 HVAC drive (BACnet MS/TP)WEG CFW701 HVAC-R frequency inverters using BACnet MS/TP on the RS-485 port. · 10001538519 / 01 Also known as: CFW701, WEG CFW701, CFW701 HVAC-R, CFW701 BACnet, 10001538519Drive9434CSVEDE
YaskawaYaskawa JOHB-SMP3 BACnet/IP option (HV600, Z1000U, GA800 drives)Yaskawa HV600, FP605, Z1000U, GA500, GA700 and GA800 drives and HV600/FP605 bypasses fitted with the JOHB-SMP3 card. · SIEP C730600 0MB Also known as: JOHB-SMP3, SMP3, HV600 BACnet/IP, Z1000U BACnet/IP, FP605 BACnet/IP, GA800 BACnet/IP, SIEP C730600 0MBDriveOption card / module21367CSVEDE
YaskawaYaskawa SI-B3 BACnet MS/TP option (A1000, P1000, U1000, FP605 drives)Yaskawa A1000, P1000, iQpump1000, U1000, FP605 and iQpump605 drives fitted with the SI-B3 BACnet MS/TP option card. · TOEP YAICOM 22B Also known as: SI-B3, SI-B3/V, A1000 BACnet, P1000 BACnet, iQpump1000 BACnet, U1000 BACnet, FP605 BACnet, iQpump605 BACnet, TOEPYAICOM22DriveOption card / module12132CSVEDE
YaskawaYaskawa Z1000 Bypass (BACnet MS/TP)Yaskawa Z1000 Bypass packages (Z1B1, 208 V and 480 V) connected to BACnet MS/TP at the bypass controller. · SIEP YAIZ1B 01F Also known as: Z1000 Bypass, Z1B1, Z1000 drive bypass, Z1000 bypass controller, SIEP YAIZ1B 01Drive19252CSVEDE
YaskawaYaskawa Z1000 HVAC drive (embedded BACnet MS/TP)Yaskawa Z1000 HVAC fan and pump drives (CIMR-ZU, 200 V and 400 V class) using the built-in RS-485 port with H5-08 set to BACnet. · SIEP C710616 45F Also known as: Z1000, CIMR-ZU, CIMR-ZUA, Z1000 AC Drive for HVAC Fan and Pump, SIEP C710616 45Drive10732CSVEDE