Room thermostat (Disio display sequence) · BACnet points list

Price Industries Disio Display DX-305 sequence BACnet points list

Updated 6 November 2026

Short answer

Disio Display is Price's room display/controller. In sequence DX-305 it exposes 66 BACnet MS/TP objects (its outputs are named Output 1 - Analog Fan, Output 2 - Heating Valve, Output 4 - Binary Fan, Output 3 - Cooling Valve), plus setpoints, loop settings, occupancy, units and network settings. The object list changes with the sequence loaded.

This page lists 66 BACnet objects for the Price Industries Disio Display DX-305 sequence — 61 of them writable — with each object’s type, instance number, name, engineering units and access. It is re-typed from Price Industries’s own free documentation, linked below.

Manufacturer
Price Industries
Model
Disio Display DX-305 sequence
Equipment
Room thermostat (Disio display sequence)
Equipment type
Thermostats, sensors & meters
BACnet objects
66 (61 writable)
Transport
BACnet MS/TP
Firmware
v1.6.14 Revision: E Version: 13
Also known as
Disio DX-305, DX-305, Disio Display, Price Disio
Source document
Disio Display BACnet Object List - DX-305 · Disio Display BACnet Object List (DX-305)
Download CSV 66 rows Download EDE B.I.G.-EU JSON Manufacturer PDF ↗ Compare with your scan Download Easy BACnet Mobile App Google Play

Reference only, provided as-is: verify against Price Industries’s current documentation and the live device before use. Not official Price Industries information. Terms of use.

BMS integration notes: Price Industries Disio Display DX-305 sequence

Integration in brief

Write MV Occupancy and the room setpoint from the BMS, and read the room temperature, occupancy source and loop loads. AV 1 MAC Address and MV Baud Rate hold the network settings.

Minimum points to map

The short list most integrators start with — enough to run the unit from a BMS. Map more as the job needs.

ObjectNameWhyAccess
MV 6OccupancyOccupied / unoccupied commandWrite
AV 6Room Temperature SetpointRoom setpointWrite
AV 13Room TemperatureRoom temperatureWrite
MV 7Occupancy SourceWhat set the occupancyRead
AV 20Cooling Loop LoadCooling loop load, %Write
AV 27Heating Loop LoadHeating loop load, %Write

Network setup

Watch out for

Price Industries Disio Display DX-305 sequence BACnet objects

Type: AI, AO, AV, BI, BO, BV, MI/MO/MV (multi-state) · Access: Read read-only, Write writable, Command writable with a priority array.

66 of 66 shown
Type
BinaryMulti-state
Access
Show
Price Industries Disio Display DX-305 sequence BACnet Points List
DescriptionStates
AI1Thermistive Input 1°F/°CWrite
AO1Output 1 - Analog FanVWrite
AO2Output 2 - Heating ValveVWrite
BO1Output 4 - Binary FanWrite
BO2Output 3 - Cooling ValveWrite
AV1MAC AddressWrite
AV2Sequence VersionRead
AV3Sequence NumberRead
AV4Hardware VersionRead
AV5LED Brightness%Write
AVmin6Room Temperature Setpoint°F/°CWrite
AV7Room Temperature Setpoint Min°F/°CWrite
AV8Room Temperature Setpoint Max°F/°CWrite
AV9DAT Heat Setpoint°F/°CWrite
AV10DAT Heat Setpoint Min°F/°CWrite
AV11DAT Heat Setpoint Max°F/°CWrite
AV12Room Temperature Offset°F/°CWrite
AVmin13Room Temperature°F/°CWrite
AV14Cooling Loop KpWrite
AV15Cooling Loop KiWrite
AV16Cooling Loop Pro Band°F/°CWrite
AV17Cooling Loop Dead Band°F/°CWrite
AV18Cooling Loop Unoccupied Dead Band°F/°CWrite
AV19Cooling Loop Service TimesWrite
AVmin20Cooling Loop Load%Write
AV21Heating Loop KpWrite
AV22Heating Loop KiWrite
AV23Heating Loop Pro Band°F/°CWrite
AV24Heating Loop Dead Band°F/°CWrite
AV25Heating Loop Unoccupied Dead Band°F/°CWrite
AV26Heating Loop Service TimesWrite
AVmin27Heating Loop Load%Write
AV28Binary Fan Min On TimeminWrite
AV29Binary Fan Min Off TimeminWrite
AV30DAT Offset°F/°CWrite
AV31DAT°F/°CWrite
AV32Analog Fan Min VVWrite
AV33Analog Fan Max VVWrite
AV34Analog Fan Min On TimeminWrite
AV35Analog Fan Min Off TimeminWrite
AV36DAT Heating Control Hold TimesWrite
AV37DAT Heating Control Min Step%Write
AV38DAT Heating Control Max Step%Write
AV39DAT Heating Control Percent Dead Band%Write
AV40DAT Heating Control Dead Band°F/°CWrite
AV41DAT Heating Control Unoccupied Percent Dead Band%Write
AV42DAT Heating Control Unoccupied Dead Band°F/°CWrite
AV43DAT Heating Control Output Value%Write
AV44Heating Valve Min VVWrite
AV45Heating Valve Max VVWrite
AV46Heating Valve Min On TimeminWrite
AV47Heating Valve Min Off TimeminWrite
AV48Cooling Valve Min On TimeminWrite
AV49Cooling Valve Min Off TimeminWrite
AV50Occupancy TimeoutminWrite
AV51Proximity Screen TimeoutsWrite
AV52Diagnostic ModeWrite
MV1Sequence RevisionRead0=A, 1=B, 2=C, 3=D, 4=E, 5=F, 6=G, 7=H, 8=I, 9=J, 10=K, 11=L, 12=M, 13=N, 14=O, 15=P, 16=Q, 17=R, 18=S, 19=T, 20=U, 21=V, 22=W, 23=X, 24=Y, 25=Z
MV2Temperature UnitsWrite0=C, 1=F
MV3Airflow UnitsWrite0=CFM, 1=L/s, 2=CMH
MV4Pressure UnitsWrite0=inches H20, 1=Pascals
MV5Baud RateWrite0=9600, 1=19200, 2=38400, 3=76800
MVmin6OccupancyWrite0=Unoccupied, 1=Occupied
MVmin7Occupancy SourceRead0=Default Occupied, 1=BACnet, 2=Button, 3=Motion
MV8Support Unoccupied ModeWrite0=No, 1=Yes
MV9Proximity Screen ModeWrite0=Dim, 1=Blank, 2=Always On
Object ID lookup: Price Industries Disio Display DX-305 sequence point IDs by name

Integration notes

Check it against the live device. A points list tells you what the controller can expose; the unit in front of you may differ by firmware or installed options. This list is provided as-is for reference only and may contain mistakes — confirming it before you write, map or commission anything is up to you (terms). Easy BACnet scans a network for BACnet IP devices from an Android phone, reads every object on the Disio Display DX-305 sequence and exports what it actually has to Excel — free. New to BACnet? Start with what a BACnet points list is and what the object types mean.

Questions about the Price Industries Disio Display DX-305 sequence

How many BACnet points does the Price Industries Disio Display DX-305 sequence have?

This list has 66 BACnet objects: 1 analog input, 2 analog outputs, 52 analog values, 2 binary outputs, 9 multi-state values. The exact set on a given unit depends on its firmware, installed options and configuration.

Which Price Industries Disio Display DX-305 sequence BACnet points are writable?

61 of the 66 objects accept a write. Points marked Command have a priority array: a write holds until it is released, so release it back to automatic when you are done.

Where is the official Price Industries Disio Display DX-305 sequence BACnet documentation?

The source is Disio Display BACnet Object List - DX-305 (Disio Display BACnet Object List (DX-305)), published free by Price Industries at https://priceindustries.com/wp-content/uploads/Assets/literature/documents---bacnet/disio-display-bacnet-points-list.pdf.

What are the minimum BACnet points to integrate the Price Industries Disio Display DX-305 sequence?

Start with MV 6 Occupancy (Occupied / unoccupied command); AV 6 Room Temperature Setpoint (Room setpoint); AV 13 Room Temperature (Room temperature); MV 7 Occupancy Source (What set the occupancy); AV 20 Cooling Loop Load (Cooling loop load, %); AV 27 Heating Loop Load (Heating loop load, %).

How do I check these points on the real Disio Display DX-305 sequence?

Scan the network with a BACnet IP browser such as Easy BACnet, open the device and compare its object list with this table. Anything missing is usually an option that isn't installed or a point that is disabled in the controller's configuration.

More Price Industries BACnet points lists

Source: Disio Display BACnet Object List - DX-305 · Disio Display BACnet Object List (DX-305). Object names, instances and units are reproduced as published; descriptions are our own.