Updated 12 November 2026

Short answer

The Acuvim II V3 meter serves 103 read-only Analog Inputs (real-time values, demand, energy, THD, AXM-IO3 analog inputs and AXM-IO pulse counters) and 44 Binary Inputs (AXM-IO digital inputs and 16 alarm channel status flags). Its object map differs from the AXM-BIP and AXM-WEB2 module lists for the older Acuvim II, for example the pulse counters sit on AI 76-103.

This page lists 147 BACnet objects for the Accuenergy Acuvim II V3 power meter (native BACnet, firmware v6.39) — 0 of them writable — with each object’s type, instance number, name, engineering units and access. It is re-typed from Accuenergy’s own free documentation, linked below.

Manufacturer
Accuenergy
Model
Acuvim II V3 power meter (native BACnet, firmware v6.39)
Equipment
Power and energy meter
Equipment type
Thermostats, sensors & meters
BACnet objects
147 (0 writable)
Transport
—
Firmware
v6.39
Also known as
Acuvim II V3, Acuvim-II V3, Acuvim II V3 BACnet, Acuvim-II_BACnet-Obj-List
Source document
BACnet Points List Acuvim II V3 · rev. 2026-10-05
Download CSV 147 rows Download EDE B.I.G.-EU JSON Manufacturer PDF ↗ Compare with your scan Download Easy BACnet Mobile App Google Play

Reference only, provided as-is: verify against Accuenergy’s current documentation and the live device before use. Not official Accuenergy information. Terms of use.

BMS integration notes: Accuenergy Acuvim II V3 power meter (native BACnet, firmware v6.39)

Integration in brief

All objects are read-only measurements. Map total power, imported energy, demand, PF, current and voltage; I/O module and alarm channel objects only matter when they are set up.

Minimum points to map

The short list most integrators start with — enough to run the unit from a BMS. Map more as the job needs.

ObjectNameWhyAccess
AI 18P_rmsTotal real power, kWRead
AI 40Active_Energy_ImpImported energy, kWhRead
AI 34P_demaReal power demand, kWRead
AI 30PF_rmsTotal power factorRead
AI 13Iavg_rmsAverage current, ARead
AI 5Uavg_rmsAverage L-N voltage, VRead
AI 1Freq_rmsFrequency, HzRead

Watch out for

Accuenergy Acuvim II V3 power meter (native BACnet, firmware v6.39) BACnet objects

Type: AI, AO, AV, BI, BO, BV, MI/MO/MV (multi-state) · Access: Read read-only, Write writable, Command writable with a priority array.

147 of 147 shown
Type
AnalogBinary
Show
Accuenergy Acuvim II V3 power meter (native BACnet, firmware v6.39) BACnet Points List
DescriptionStates
AImin1Freq_rmsFrequencyHzRead
AI2Ua_rmsPhase A VoltageVRead
AI3Ub_rmsPhase B VoltageVRead
AI4Uc_rmsPhase C VoltageVRead
AImin5Uavg_rmsAverage Phase VoltageVRead
AI6Uab_rmsLine Voltage ABVRead
AI7Ubc_rmsLine Voltage BCVRead
AI8Uca_rmsLine Voltage CAVRead
AI9Ulavg_rmsAverage Line VoltageVRead
AI10Ia_rmsPhase A CurrentARead
AI11Ib_rmsPhase B CurrentARead
AI12Ic_rmsPhase C CurrentARead
AImin13Iavg_rmsAverage CurrentARead
AI14In_rmsNeutral CurrentARead
AI15Pa_rmsPhase A Active PowerkWRead
AI16Pb_rmsPhase B Active PowerkWRead
AI17Pc_rmsPhase C Active PowerkWRead
AImin18P_rmsTotal Active PowerkWRead
AI19Qa_rmsPhase A Reactive PowerkvarRead
AI20Qb_rmsPhase B Reactive PowerkvarRead
AI21Qc_rmsPhase C Reactive PowerkvarRead
AI22Q_rmsTotal Reactive PowerkvarRead
AI23Sa_rmsPhase A Apparent PowerkVARead
AI24Sb_rmsPhase B Apparent PowerkVARead
AI25Sc_rmsPhase C Apparent PowerkVARead
AI26S_rmsTotal Apparent PowerkVARead
AI27PFa_rmsPhase A Power FactorRead
AI28PFb_rmsPhase B Power FactorRead
AI29PFc_rmsPhase C Power FactorRead
AImin30PF_rmsTotal Power FactorRead
AI31U_unblVoltage Unbalance FactorRead
AI32I_unblCurrent Unbalance FactorRead
AI33Rlc_valLoad Type (82:Resistive load 76:Inductive load 67:Capacitive load)Read
AImin34P_demaActive Power DemandkWRead
AI35Q_demaReactive Power DemandkvarRead
AI36S_demaApparent Power DemandkVARead
AI37Ia_demaPhase A Current DemandARead
AI38Ib_demaPhase B Current DemandARead
AI39Ic_demaPhase C Current DemandARead
AImin40Active_Energy_ImpImport Active EnergykWhRead
AI41Active_Energy_ExpExport Active EnergykWhRead
AI42Reactive_Energy_ImpImport Reactive EnergykvarhRead
AI43Reactive_Energy_ExpExport Reactive EnergykvarhRead
AI44Active_Energy_TotalActive Energy TotalkWhRead
AI45Active_Energy_NetActive Energy NetkWhRead
AI46Reactive_Energy_TotalReactive Energy TotalkvarhRead
AI47Reactive_Energy_NetReactive Energy NetkvarhRead
AI48Apparent_EnergyApparent EnergykVAhRead
AI49Active_Energy_Imp_APhase A Import Active EnergykWhRead
AI50Active_Energy_Exp_APhase A Export Active EnergykWhRead
AI51Active_Energy_Imp_BPhase B Import Active EnergykWhRead
AI52Active_Energy_Exp_BPhase B Export Active EnergykWhRead
AI53Active_Energy_Imp_CPhase C Import Active EnergykWhRead
AI54Active_Energy_Exp_CPhase C Export Active EnergykWhRead
AI55Reactive_Energy_Imp_APhase A Import Reactive EnergykvarhRead
AI56Reactive_Energy_Exp_APhase A Export Reactive EnergykvarhRead
AI57Reactive_Energy_Imp_BPhase B Import Reactive EnergykvarhRead
AI58Reactive_Energy_Exp_BPhase B Export Reactive EnergykvarhRead
AI59Reactive_Energy_Imp_CPhase C Import Reactive EnergykvarhRead
AI60Reactive_Energy_Exp_CPhase C Export Reactive EnergykvarhRead
AI61Apparent_Energy_APhase A Apparent EnergykVAhRead
AI62Apparent_Energy_BPhase B Apparent EnergykVAhRead
AI63Apparent_Energy_CPhase C Apparent EnergykVAhRead
AI64V1_thdVoltage 1 THDVRead
AI65V2_thdVoltage 2 THDVRead
AI66V3_thdVoltage 3 THDVRead
AI67V_thdAverage Voltage THDVRead
AI68I1_thdCurrent 1 THDARead
AI69I2_thdCurrent 2 THDARead
AI70I3_thdCurrent 3 THDARead
AI71I_thdAverage Current THDARead
AI72IO31_ai1IO31 Analog Input 1Read
AI73IO31_ai2IO31 Analog Input 2Read
AI74IO32_ai1IO32 Analog Input 1Read
AI75IO32_ai2IO32 Analog Input 2Read
AI76IO11_pc1IO11 Pulse Counter 1Read
AI77IO11_pc2IO11 Pulse Counter 2Read
AI78IO11_pc3IO11 Pulse Counter 3Read
AI79IO11_pc4IO11 Pulse Counter 4Read
AI80IO11_pc5IO11 Pulse Counter 5Read
AI81IO11_pc6IO11 Pulse Counter 6Read
AI82IO21_pc1IO21 Pulse Counter 1Read
AI83IO21_pc2IO21 Pulse Counter 2Read
AI84IO21_pc3IO21 Pulse Counter 3Read
AI85IO21_pc4IO21 Pulse Counter 4Read
AI86IO31_pc1IO31 Pulse Counter 1Read
AI87IO31_pc2IO31 Pulse Counter 2Read
AI88IO31_pc3IO31 Pulse Counter 3Read
AI89IO31_pc4IO31 Pulse Counter 4Read
AI90IO12_pc1IO12 Pulse Counter 1Read
AI91IO12_pc2IO12 Pulse Counter 2Read
AI92IO12_pc3IO12 Pulse Counter 3Read
AI93IO12_pc4IO12 Pulse Counter 4Read
AI94IO12_pc5IO12 Pulse Counter 5Read
AI95IO12_pc6IO12 Pulse Counter 6Read
AI96IO22_pc1IO22 Pulse Counter 1Read
AI97IO22_pc2IO22 Pulse Counter 2Read
AI98IO22_pc3IO22 Pulse Counter 3Read
AI99IO22_pc4IO22 Pulse Counter 4Read
AI100IO32_pc1IO32 Pulse Counter 1Read
AI101IO32_pc2IO32 Pulse Counter 2Read
AI102IO32_pc3IO32 Pulse Counter 3Read
AI103IO32_pc4IO32 Pulse Counter 4Read
BI1IO11_di1IO11 Digital Input 1Read
BI2IO11_di2IO11 Digital Input 2Read
BI3IO11_di3IO11 Digital Input 3Read
BI4IO11_di4IO11 Digital Input 4Read
BI5IO11_di5IO11 Digital Input 5Read
BI6IO11_di6IO11 Digital Input 6Read
BI7IO21_di1IO21 Digital Input 1Read
BI8IO21_di2IO21 Digital Input 2Read
BI9IO21_di3IO21 Digital Input 3Read
BI10IO21_di4IO21 Digital Input 4Read
BI11IO31_di1IO31 Digital Input 1Read
BI12IO31_di2IO31 Digital Input 2Read
BI13IO31_di3IO31 Digital Input 3Read
BI14IO31_di4IO31 Digital Input 4Read
BI15IO12_di1IO12 Digital Input 1Read
BI16IO12_di2IO12 Digital Input 2Read
BI17IO12_di3IO12 Digital Input 3Read
BI18IO12_di4IO12 Digital Input 4Read
BI19IO12_di5IO12 Digital Input 5Read
BI20IO12_di6IO12 Digital Input 6Read
BI21IO22_di1IO22 Digital Input 1Read
BI22IO22_di2IO22 Digital Input 2Read
BI23IO22_di3IO22 Digital Input 3Read
BI24IO22_di4IO22 Digital Input 4Read
BI25IO32_di1IO32 Digital Input 1Read
BI26IO32_di2IO32 Digital Input 2Read
BI27IO32_di3IO32 Digital Input 3Read
BI28IO32_di4IO32 Digital Input 4Read
BI29AlarmStatus1Alarm Channel 1 StatusRead
BI30AlarmStatus2Alarm Channel 2 StatusRead
BI31AlarmStatus3Alarm Channel 3 StatusRead
BI32AlarmStatus4Alarm Channel 4 StatusRead
BI33AlarmStatus5Alarm Channel 5 StatusRead
BI34AlarmStatus6Alarm Channel 6 StatusRead
BI35AlarmStatus7Alarm Channel 7 StatusRead
BI36AlarmStatus8Alarm Channel 8 StatusRead
BI37AlarmStatus9Alarm Channel 9 StatusRead
BI38AlarmStatus10Alarm Channel 10 StatusRead
BI39AlarmStatus11Alarm Channel 11 StatusRead
BI40AlarmStatus12Alarm Channel 12 StatusRead
BI41AlarmStatus13Alarm Channel 13 StatusRead
BI42AlarmStatus14Alarm Channel 14 StatusRead
BI43AlarmStatus15Alarm Channel 15 StatusRead
BI44AlarmStatus16Alarm Channel 16 StatusRead
Object ID lookup: Accuenergy Acuvim II V3 power meter point IDs by name

Integration notes

Check it against the live device. A points list tells you what the controller can expose; the unit in front of you may differ by firmware or installed options. This list is provided as-is for reference only and may contain mistakes — confirming it before you write, map or commission anything is up to you (terms). Easy BACnet scans a network for BACnet IP devices from an Android phone, reads every object on the Acuvim II V3 power meter (native BACnet, firmware v6.39) and exports what it actually has to Excel — free. New to BACnet? Start with what a BACnet points list is and what the object types mean.

Questions about the Accuenergy Acuvim II V3 power meter (native BACnet, firmware v6.39)

How many BACnet points does the Accuenergy Acuvim II V3 power meter (native BACnet, firmware v6.39) have?

This list has 147 BACnet objects: 103 analog inputs, 44 binary inputs. The exact set on a given unit depends on its firmware, installed options and configuration.

Which Accuenergy Acuvim II V3 power meter (native BACnet, firmware v6.39) BACnet points are writable?

None of the listed objects are marked writable in the source documentation.

Where is the official Accuenergy Acuvim II V3 power meter (native BACnet, firmware v6.39) BACnet documentation?

The source is BACnet Points List Acuvim II V3, revision 2026-10-05, published free by Accuenergy at https://www.accuenergy.com/wp-content/uploads/Acuvim-II_BACnet-Obj-List.xlsx.

What are the minimum BACnet points to integrate the Accuenergy Acuvim II V3 power meter (native BACnet, firmware v6.39)?

Start with AI 18 P_rms (Total real power, kW); AI 40 Active_Energy_Imp (Imported energy, kWh); AI 34 P_dema (Real power demand, kW); AI 30 PF_rms (Total power factor); AI 13 Iavg_rms (Average current, A); AI 5 Uavg_rms (Average L-N voltage, V); AI 1 Freq_rms (Frequency, Hz).

How do I check these points on the real Acuvim II V3 power meter (native BACnet, firmware v6.39)?

Scan the network with a BACnet IP browser such as Easy BACnet, open the device and compare its object list with this table. Anything missing is usually an option that isn't installed or a point that is disabled in the controller's configuration.

More Accuenergy BACnet points lists

Source: BACnet Points List Acuvim II V3 · rev. 2026-10-05. Object names, instances and units are reproduced as published; descriptions are our own.