Room operating unit / room sensor · BACnet points list
Thermokon NOVOS 3 / NOVOS 5 RS485 BACnet room operating units BACnet points list
Updated 4 November 2026
NOVOS 3 and NOVOS 5 are wall-mounted room sensors and operating units with a BACnet MS/TP interface. They measure temperature and, depending on the variant, humidity, CO2 and VOC, and offer occupancy, setpoint and fan-stage inputs for the room controller in the BMS. Only the main operating values are BACnet objects; the rest is set through a configuration file written with Thermokon's uConfig tool.
This page lists 32 BACnet objects for the Thermokon NOVOS 3 / NOVOS 5 RS485 BACnet room operating units — 21 of them writable — with each object’s type, instance number, name, engineering units and access. It is re-typed from Thermokon’s own free documentation, linked below.
- Manufacturer
- Thermokon
- Model
- NOVOS 3 / NOVOS 5 RS485 BACnet room operating units
- Equipment
- Room operating unit / room sensor
- Equipment type
- Thermostats, sensors & meters
- BACnet objects
- 32 (21 writable)
- Transport
- BACnet MS/TP
- Firmware
- Not stated
- Default device instance
- Device Offset ID + MAC address
- Also known as
- NOVOS 3 RS485 BACnet, NOVOS 5 LCD RS485 BACnet, NOVOS 3 x, NOVOS 5 x, NOVOS 5 LCD
Reference only, provided as-is: verify against Thermokon’s current documentation and the live device before use. Not official Thermokon information. Terms of use.
BMS integration notes: Thermokon NOVOS 3 / NOVOS 5 RS485 BACnet room operating units
Set the MAC address and baud rate with the DIP switches, and the Device Offset ID if needed. Read the sensor AIs and the occupancy, setpoint and fan-stage objects and feed them to the room controller in the BMS; write the LED and icon objects to show states back to the user.
Minimum points to map
The short list most integrators start with — enough to run the unit from a BMS. Map more as the job needs.
| Object | Name | Why | Access |
|---|---|---|---|
| BV 100 | Occupancy | Room occupied (button), also writable from the BMS | Write |
| AV 103 | Setpoint | Room setpoint set on the unit | Write |
| MV 104 | Fan Stage | Fan stage selected on the unit | Read |
| AI 500 | Temperature | Room temperature | Read |
| AI 501 | Relative Humidity | Room humidity (rH variants) | Read |
| AI 505 | CO2 | Room CO2 (CO2 variants) | Read |
| BI 514 | Digital Input | Window or other contact, 1 = closed | Read |
Network setup
- MAC address 1-127 and baud rate (9600-115200) are set on DIP switches; 8N1.
- Device instance = Device Offset ID (AV 4180) + MAC address.
- Most settings (setpoint range, fan options, offsets, LCD behaviour) are written as a config file with uConfig via BACnet file transfer (FILE 0).
Watch out for
- LED objects are not stored; write them again after the device restarts.
- Changing the unit system to imperial does not rescale the measured-value limits; adjust them by hand.
Thermokon NOVOS 3 / NOVOS 5 RS485 BACnet room operating units BACnet objects
Type: AI, AO, AV, BI, BO, BV, MI/MO/MV (multi-state) · Access: Read read-only, Write writable, Command writable with a priority array.
Note: the source document has no read/write column, so access here is inferred from the object type (inputs read-only, values writable). Confirm on the live controller before writing.
| Description | States | |||||
|---|---|---|---|---|---|---|
| DEV | x_Novos 3/5 BACnet MSTP | Device object; instance = Device Offset ID + MAC address | Read | |||
| MO | 1041 | Device Reset | Restart the device | Write | 1=running, 2=Reset, 3=Reboot | |
| AV | 4180 | Device Offset ID | Offset added to the MAC address for the device instance | Write | ||
| MV | 4183 | COV Mode | COV notifications off, local or global broadcast | Write | 1=off, 2=Local, 3=Global | |
| FILE | 0 | config.bin | Configuration file transfer (uConfig) | Write | ||
| BVmin | 100 | Occupancy | Room occupancy (toggled by the button) | Write | 0=Unoccupied, 1=Occupied | |
| AVmin | 103 | Setpoint | Effective room setpoint | °C | Write | |
| MVmin | 104 | Fan Stage | Currently active fan stage | Read | 1=off, 2=Stage 1, 3=Stage 2, 4=Stage 3, 5=Stage 4, 6=Stage 5, 7=Auto | |
| MV | 105 | Auto Fan Stage | Fan stage shown when the fan is in Auto | Write | 1=Auto, 2=Auto 0, 3=Auto 1, 4=Auto 2, 5=Auto 3, 6=Auto 4, 7=Auto 5 | |
| MV | 426 | LED State | Button LED on/off or occupancy indication | Write | 1=off, 2=on, 3=Occupancy | |
| MV | 427 | LED Color | Button LED colour | Write | 1=white, 2=black, 3=red, 4=green, 5=blue, 6=yellow, 7=magenta, 8=cyan | |
| AImin | 500 | Temperature | Room temperature | °C | Read | |
| AImin | 501 | Relative Humidity | Room relative humidity | % | Read | |
| AI | 502 | Absolute Humidity | Absolute humidity | g/m³ | Read | |
| AI | 503 | Enthalpy | Enthalpy | kJ/kg | Read | |
| AI | 504 | Dewpoint | Dew point | °C | Read | |
| AImin | 505 | CO2 | CO2 concentration | ppm | Read | |
| AI | 506 | VOC | VOC level | % | Read | |
| AI | 507 | CO2 / VOC Mix | Combined CO2/VOC air quality index | % | Read | |
| BImin | 514 | Digital Input | Potential-free contact status | Read | 0=open, 1=closed | |
| BV | 16 | Show Icon Condensation | Show the condensation icon on the LCD | Write | 0=off, 1=on | |
| BV | 17 | Show Icon Window open | Show the window open icon on the LCD | Write | 0=off, 1=on | |
| BV | 18 | Show Icon Calibration | Show the calibration icon on the LCD | Write | 0=off, 1=on | |
| BV | 19 | Show Icon Communication Error | Show the communication error icon on the LCD | Write | 0=off, 1=on | |
| BV | 20 | Show Icon Communication Mode | Show the communication mode icon on the LCD | Write | 0=off, 1=on | |
| BV | 21 | Show Icon ECO | Show the eco icon on the LCD | Write | 0=off, 1=on | |
| BV | 22 | Show Icon Heating | Show the heating icon on the LCD | Write | 0=off, 1=on | |
| BV | 23 | Show Icon Cooling | Show the cooling icon on the LCD | Write | 0=off, 1=on | |
| BV | 24 | Show Icon Movement | Show the movement icon on the LCD | Write | 0=off, 1=on | |
| BV | 25 | Show Icon Occupancy | Show the occupancy icon on the LCD | Write | 0=off, 1=on | |
| BV | 26 | Show Icon Warning | Show the warning icon on the LCD | Write | 0=off, 1=on | |
| BV | 27 | Show Icon Service | Show the service icon on the LCD | Write | 0=off, 1=on |
No points match these filters.
Object ID lookup: Thermokon NOVOS 3/5 BACnet point IDs by name
MO1041Device ResetAV4180Device Offset IDMV4183COV ModeFILE0config.binBV100OccupancyAV103SetpointMV104Fan StageMV105Auto Fan StageMV426LED StateMV427LED ColorAI500TemperatureAI501Relative HumidityAI502Absolute HumidityAI503EnthalpyAI504DewpointAI505CO2AI506VOCAI507CO2 / VOC MixBI514Digital InputBV16Show Icon CondensationBV17Show Icon Window openBV18Show Icon CalibrationBV19Show Icon Communication ErrorBV20Show Icon Communication ModeBV21Show Icon ECOBV22Show Icon HeatingBV23Show Icon CoolingBV24Show Icon MovementBV25Show Icon OccupancyBV26Show Icon WarningBV27Show Icon Service
Integration notes
- Object list from the 'Description of RS485 BACnet Interface NOVOS 3 / NOVOS 5' manual, rev D, pages 4-9. Object names are printed in square brackets in the manual; the brackets are dropped here.
- Which AI objects are present depends on the sensor variant (Temp, CO2 Temp, CO2 Temp_rH, CO2+VOC Temp, CO2+VOC Temp_rH).
- The icon objects (BV 16-27) apply to the NOVOS 5 LCD; the LED objects (MV 426-427) to units with an LED button.
- Temperatures switch to °F when the unit system is set to imperial in uConfig.
- The manual has no access column; R/W here is inferred from the descriptions.
Check it against the live device. A points list tells you what the controller can expose; the unit in front of you may differ by firmware or installed options. This list is provided as-is for reference only and may contain mistakes — confirming it before you write, map or commission anything is up to you (terms). Easy BACnet scans a network for BACnet IP devices from an Android phone, reads every object on the NOVOS 3 / NOVOS 5 RS485 BACnet room operating units and exports what it actually has to Excel — free. New to BACnet? Start with what a BACnet points list is and what the object types mean.
Questions about the Thermokon NOVOS 3 / NOVOS 5 RS485 BACnet room operating units
How many BACnet points does the Thermokon NOVOS 3 / NOVOS 5 RS485 BACnet room operating units have?
This list has 32 BACnet objects: 8 analog inputs, 2 analog values, 1 binary input, 13 binary values, 1 device, 1 file, 1 multi-state output, 5 multi-state values. The exact set on a given unit depends on its firmware, installed options and configuration.
Which Thermokon NOVOS 3 / NOVOS 5 RS485 BACnet room operating units BACnet points are writable?
21 of the 32 objects accept a write. Points marked Command have a priority array: a write holds until it is released, so release it back to automatic when you are done. The source has no read/write column, so this is inferred from object type.
Where is the official Thermokon NOVOS 3 / NOVOS 5 RS485 BACnet room operating units BACnet documentation?
The source is Description of RS485 BACnet Interface NOVOS 3 / NOVOS 5, revision Rev. D, 18.06.2026, published free by Thermokon at https://www.thermokon.de/direct/alterra-base/mimes/get/3f7260a25eb0435a3.
What are the minimum BACnet points to integrate the Thermokon NOVOS 3 / NOVOS 5 RS485 BACnet room operating units?
Start with BV 100 Occupancy (Room occupied (button), also writable from the BMS); AV 103 Setpoint (Room setpoint set on the unit); MV 104 Fan Stage (Fan stage selected on the unit); AI 500 Temperature (Room temperature); AI 501 Relative Humidity (Room humidity (rH variants)); AI 505 CO2 (Room CO2 (CO2 variants)); BI 514 Digital Input (Window or other contact, 1 = closed).
How do I check these points on the real NOVOS 3 / NOVOS 5 RS485 BACnet room operating units?
Scan the network with a BACnet IP browser such as Easy BACnet, open the device and compare its object list with this table. Anything missing is usually an option that isn't installed or a point that is disabled in the controller's configuration.
More Thermokon BACnet points lists
- Room sensor / operating unit
Thermokon FTW04 BACnet MS/TP RS485 room humidity/temperature unit
Thermokon FTW04 BACnet MS/TP RS485 room units (temperature, humidity, optional setpoint, button, rotary switch, LED, 2 digital inputs, 2 analogue outputs).
Also known as: FTW04, FTW04 BACnet, FTW04_BACnet, FTW04-RS485-BACnet - Room thermostat / fan coil controller
Thermokon JOY BACnet room thermostats / fan coil controllers (5DO, ECAO2DO, HCAO2DO, EC3AO, HC3AO)
Thermokon JOY wall thermostats with RS485 BACnet MS/TP for fan coils, heating/cooling valves and 6-way valves, in 230 V and 24 V versions with optional CO2 and humidity sensors.
Also known as: JOY FC5DO BACnet, JOY ECAO2DO BACnet, JOY HCAO2DO BACnet, JOY EC3AO BACnet, JOY HC3AO BACnet, JOY HC AO2DO 24V RS485 BACnet, JOY RS485 BACnet - Room operating unit / room sensor
Thermokon NOVOS 7 / NOVOS Touch / thanos EVO RS485 BACnet room operating units
Thermokon NOVOS 7, NOVOS Touch and thanos EVO touch-screen room operating units with RS485 BACnet MS/TP.
Also known as: NOVOS 7, NOVOS Touch, thanos EVO, NOVOS 7 RS485 BACnet, thanos EVO RS485 BACnet - Duct / room sensor (temperature, humidity, CO2, VOC, pressure)
Thermokon USE-BACnet MS/TP option for Thermokon sensors (FTA+, LK+, DPA+, LI65+ ...)
Thermokon sensors fitted with the USE-BACnet MS/TP RS485 option board (FTA+, FTK+, LK+, DPA+, LI65+, LDF+, RDF+, WK02+ and their LCD versions).
Also known as: USE BACnet, USE-RS485 BACnet, FTA+ BACnet, FTK+ BACnet, LK+ CO2 BACnet, LK+ VOC BACnet, DPA+ BACnet, DPA+ Flow BACnet, LI65+ BACnet, LDF+ BACnet, RDF+ BACnet, WK02+ BACnet - Room sensor / operating unit
Thermokon WRF04 BACnet MS/TP RS485 room operating unit
Thermokon WRF04 BACnet MS/TP RS485 room units (temperature, optional setpoint, button, rotary switch, LED, 2 digital inputs, 2 analogue outputs).
Also known as: WRF04, WRF04 BACnet, WRF04_BACnet, WRF04-RS485-BACnet - Room sensor (CO2, VOC, temperature, humidity)
Thermokon WRF06 AQ / FTW06 RS485 BACnet MS/TP room sensors
Thermokon WRF06 AQ room air quality sensors (CO2, VOC, temperature, humidity variants) and FTW06 room humidity/temperature sensors with RS485 BACnet MS/TP.
Also known as: WRF06 AQ, WRF06 CO2, WRF06 CO2 Temp, WRF06 CO2 Temp_rH, WRF06 CO2+VOC, WRF06 VOC Temp, FTW06, WRF06 AQ BACnet MSTP - Room controller (fan coil, radiator, chilled ceiling)
Thermokon WRF06 RC / WRF07 RC BACnet MS/TP room controllers
Thermokon WRF06 RC and WRF07 RC wall-mounted room controllers with RS485 BACnet MS/TP, including the humidity (x rH) variants.
Also known as: WRF06 RC BACnet MS/TP, WRF06 RC (x) BACnet MS/TP, WRF07 RC (x) BACnet MS/TP, WRF07 RC, WRF06 RC, WRF07 BACnet MSTP - Room operating unit (buttons, LCD, setpoints) / room sensor
Thermokon WRF08 BACnet MS/TP RS485 room operating panel
Thermokon WRF08 room operating panels with LCD, up to 12 buttons, room temperature sensor and BACnet MS/TP over RS485.
Also known as: WRF08, WRF08 BACnet, WRF08 RS485 BACnet, Thermokon_WRF08_BACnet
Source: Description of RS485 BACnet Interface NOVOS 3 / NOVOS 5 · rev. Rev. D, 18.06.2026. Object names, instances and units are reproduced as published; descriptions are our own.