Variable frequency drive · BACnet points list
Danfoss iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN) BACnet points list
Updated 7 November 2026
Danfoss iC7 drives talk BACnet/IP over the X1/X2 Ethernet ports with the OS7BI option, or BACnet MS/TP with the OS7BN option. Both operating guides print the same fixed object list: I/O values for the integrated and general-purpose I/O, run/stop and speed reference, drive measurements and hour/energy counters, PID and multi-zone setpoints, fixed-speed pump (MPC) data, and the fieldbus control and status word bits.
This page lists 141 BACnet objects for the Danfoss iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN) — 54 of them writable — with each object’s type, instance number, name, engineering units and access. It is re-typed from Danfoss’s own free documentation, linked below.
- Manufacturer
- Danfoss
- Model
- iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN)
- Equipment
- Variable frequency drive
- Equipment type
- VFDs & pumps
- BACnet objects
- 141 (54 writable)
- Transport
- BACnet IP, BACnet MS/TP
- Firmware
- Not stated
- Default device instance
- 1
- Also known as
- iC7-Automation, iC7-Hybrid, OS7BI, OS7BN, iC7 BACnet/IP, iC7 BACnet MSTP, 136R0460, 136R0437
Reference only, provided as-is: verify against Danfoss’s current documentation and the live device before use. Not official Danfoss information. Terms of use.
BMS integration notes: Danfoss iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN)
Set Control Place Selection to Advanced Control/Fieldbus Control and the fieldbus reference and start sources to Fieldbus (parameter group 5.5), then write BV 1 RUN/STOP Command and AV 1 Fieldbus Speed Reference 1. Read Running (BV 33), Motor Speed (AV 3), current and power, and the Trip/Warning flags with Fault Status Word 1 for alarms.
Minimum points to map
The short list most integrators start with — enough to run the unit from a BMS. Map more as the job needs.
| Object | Name | Why | Access |
|---|---|---|---|
| BV 1 | RUN/STOP Command | Run/stop command (1 = run) | Write |
| AV 1 | Fieldbus Speed Reference 1 (Input Reference 1) | Speed reference, % | Write |
| AV 30 | Multi Zone Reference 1 (Setpoint 1) | Setpoint 1 when the drive runs its own PID | Write |
| BV 33 | Running | Running status | Read |
| AV 3 | Motor Speed (Motor Actual Speed) | Actual motor speed, % | Write |
| AV 5 | Motor Current | Motor current, A | Read |
| AV 6 | Output Power | Output power, kW | Read |
| BV 22 | Trip | Drive tripped | Read |
| BV 21 | Warning | Active warning | Read |
| AV 61 | Fault Status Word 1 | Fault code word | Read |
Enable & remote start
Parameter group 5.5 Control Places: Control Place Selection (5.5.2.1, also AV 49) must be Advanced Control or Fieldbus Control, with Fieldbus Speed Reference Source and the Advanced Start/Stop/Coast inputs set to Fieldbus.
Heartbeat & communication loss
BACnet Connection Timeout (10.3.7.2.14, default 60 s, 10-18000 s) watches the fieldbus data. The response (10.3.7.2.16) can be set to info, warning, warning with a switch to the alternative control place (10.3.7.2.15), or fault (ramp then coast, or coast).
Network setup
- Device instance is parameter 10.3.7.2.1 (default 1, range 1-4194303); APDU segment timeout default 5000 ms and APDU timeout default 6000 ms.
- BACnet/IP: the X1/X2 Ethernet ports carry the fieldbus; BBMD and foreign-device registration are set through the Network Port object.
- BACnet MS/TP (OS7BN): baud 9600-115200, Max Masters default 32 (0-127) and Max Info Frames default 1 (parameters 10.3.7.2.2-3).
- A cold start resets drive parameters to factory defaults but keeps the BACnet communication settings.
Watch out for
- Warm and cold start (ReinitializeDevice) are refused while the drive is running.
- Control word bits 12-15 (BV 80-83) are user-defined; their function is set by parameters.
- Fault Reset (BV 3) is printed read-only in the object table, so check on site whether a reset can be written over the network.
Danfoss iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN) BACnet objects
Type: AI, AO, AV, BI, BO, BV, MI/MO/MV (multi-state) · Access: Read read-only, Write writable, Command writable with a priority array.
| Description | States | |||||
|---|---|---|---|---|---|---|
| AI | 20 | Analog Input (T33) | Parameter 1611 (9.3.4 [101]) | % | Read | |
| AI | 21 | Analog Input (T34) | Parameter 1612 (9.3.5 [101]) | % | Read | |
| AI | 22 | Analog Input (T2) | Parameter 1620 (9.3.3 [201]) | % | Read | |
| AI | 23 | Analog Input (T3) | Parameter 1621 (9.3.4 [201]) | % | Read | |
| AI | 24 | Temperature Input (T34) | Parameter 1616 (9.3.6 [101]) | °C | Read | |
| AI | 25 | Temperature Input 1 (T2) | Parameter 4966 (9.3.6 [201]) | °C | Read | |
| AI | 26 | Temperature Input 2 (T3) | Parameter 4967 (9.3.7 [201]) | °C | Read | |
| AO | 0 | Analog Output 1 (T31) | Parameter 1613 (9.3.3 [101]) | % | Write | |
| AO | 3 | Analog Output (T4) | Parameter 1622 (9.3.5 [201]) | % | Write | |
| AVmin | 1 | Fieldbus Speed Reference 1 (Input Reference 1) | Parameter 1611 (9.3.4 [101]) | % | Write | |
| AVmin | 3 | Motor Speed (Motor Actual Speed) | Parameter 1612 (9.3.5 [101]) | % | Write | |
| AVmin | 5 | Motor Current | Parameter 1620 (9.3.3 [201]) | A | Read | |
| AVmin | 6 | Output Power | Parameter 1621 (9.3.4 [201]) | kW | Read | |
| AV | 7 | Fieldbus Process Reference | Parameter 1616 (9.3.6 [101]) | % | Read | |
| AV | 15 | Motor Thermal Overload (ETR) | Parameter 2951 (4.1.16) | % | Read | |
| AV | 16 | Line-To-Line Voltage (RMS) | Parameter 9040 (1.1.2) | V | Read | |
| AV | 17 | L1-L2 Line Voltage (RMS) | Parameter 9048 (1.1.3) | V | Read | |
| AV | 18 | L2-L3 Line Voltage (RMS) | Parameter 9049 (1.1.4) | V | Read | |
| AV | 19 | L3-L1 Line Voltage (RMS) | Parameter 9050 (1.1.5) | V | Read | |
| AV | 20 | Control Unit On Time | Parameter 2000 (6.5.1) | h | Read | |
| AV | 21 | Power Unit On Time | Parameter 2001 (6.5.2) | h | Read | |
| AV | 22 | Active Running Hours | Parameter 2009 (6.5.9) | h | Read | |
| AV | 23 | Energy Consumption | Parameter 2002 (6.5.3) | kWh | Read | |
| AV | 24 | Motor Voltage | Parameter 9005 (4.1.6) | V | Read | |
| AV | 25 | Output Frequency | Parameter 9015 (5.8.1.3) | Hz | Read | |
| AV | 26 | Torque | Parameter 1708 (4.1.12) | % | Read | |
| AV | 27 | DC Link Voltage | Parameter 9044 (2.1.3) | V | Read | |
| AV | 28 | Heat Sink Temperature | Parameter 2950 (2.1.15) | °C | Read | |
| AVmin | 30 | Multi Zone Reference 1 (Setpoint 1) | Parameter 6383 (5.10.8.1) | % | Write | |
| AV | 32 | Feedback 1 | Parameter 6080 (5.10.1.6) | % | Read | |
| AV | 35 | Multi Zone Reference 2 (Setpoint 2) | Parameter 6384 (5.10.8.2) | % | Write | |
| AV | 37 | Feedback 2 | Parameter 6085 (5.10.1.7) | % | Read | |
| AV | 40 | Multi Zone Reference 3 (Setpoint 3) | Parameter 6285 (5.10.8.3) | % | Write | |
| AV | 42 | Feedback 3 | Parameter 6104 (5.10.1.8) | % | Read | |
| AV | 47 | Control Unit Temperature | Parameter 2952 (6.1.1.3) | °C | Read | |
| AV | 49 | Control Place Selection | Parameter 114 (5.5.2.1) | Write | ||
| AV | 51 | Occurrence Number | Parameter 1610 (6.1.1.1) | Read | ||
| AV | 52 | PID Start Speed | Parameter 6056 (5.10.3.24) | Hz | Write | |
| AV | 53 | On Reference Bandwidth | Parameter 6050 (5.10.2.1) | % | Write | |
| AV | 54 | PID Proportional Gain | Parameter 6065 (5.10.5.1) | Write | ||
| AV | 55 | PID Integral Time | Parameter 6058 (5.10.5.2) | s | Write | |
| AV | 56 | PID Derivative Time | Parameter 6068 (5.10.5.5) | s | Write | |
| AV | 57 | PID Derivative Gain | Parameter 6069 (5.10.5.6) | Write | ||
| AV | 59 | Process Controller output (PID Output) | Parameter 6075 (5.10.1.2) | % | Write | |
| AV | 60 | Reserved | Parameter 6092 (5.10.1.3) | Read | ||
| AVmin | 61 | Fault Status Word 1 | Parameter 6203 (5.1.5) | Read | ||
| AV | 66 | Warning Word | Parameter 6205 (5.1.8) | Read | ||
| AV | 70 | Feedback | Parameter 6090 (5.10.1.4) | % | Read | |
| AV | 71 | Converted Signal 1 | Parameter 6700 | m³/h | Read | |
| AV | 72 | Converted Signal | Parameter 6701 | m³/h | Write | |
| AV | 77 | Converted Signal 3 | Parameter 6702 | m³/h | Read | |
| AV | 153 | MPC Status | Parameter 5367 (5.31.2.1.1) | Read | ||
| AV | 154 | Number of Fixed-Speed Pumps Running | Parameter 5331 (5.31.2.1.2) | Read | ||
| AV | 155 | Fixed-Speed Pump 1 Status | Parameter 5340 (5.31.2.1.3) | Read | ||
| AV | 156 | Fixed-Speed Pump 2 Status | Parameter 5341 (5.31.2.1.4) | Read | ||
| AV | 157 | Fixed-Speed Pump 3 Status | Parameter 5342 (5.31.2.1.5) | Read | ||
| AV | 158 | Fixed-Speed Pump 4 Status | Parameter 5343 (5.31.2.1.6) | Read | ||
| AV | 159 | Fixed-Speed Pump 5 Status | Parameter 5344 (5.31.2.1.7) | Read | ||
| AV | 163 | Fixed-Speed Pump 1 Running Hours | Parameter 5350 (5.31.2.1.8) | h | Write | |
| AV | 164 | Fixed-Speed Pump 2 Running Hours | Parameter 5351 (5.31.2.1.9) | h | Write | |
| AV | 165 | Fixed-Speed Pump 3 Running Hours | Parameter 5352 (5.31.2.1.10) | h | Write | |
| AV | 166 | Fixed-Speed Pump 4 Running Hours | Parameter 5353 (5.31.2.1.11) | h | Write | |
| AV | 167 | Fixed-Speed Pump 5 Running Hours | Parameter 5354 (5.31.2.1.12) | h | Write | |
| AV | 171 | Fixed-Speed Pump 1 Number of Starts | Parameter 5357 (5.31.2.1.13) | Read | ||
| AV | 172 | Fixed-Speed Pump 2 Number of Starts | Parameter 5358 (5.31.2.1.14) | Read | ||
| AV | 173 | Fixed-Speed Pump 3 Number of Starts | Parameter 5359 (5.31.2.1.15) | Read | ||
| AV | 174 | Fixed-Speed Pump 4 Number of Starts | Parameter 5360 (5.31.2.1.16) | Read | ||
| AV | 175 | Fixed-Speed Pump 5 Number of Starts | Parameter 5361 (5.31.2.1.17) | Read | ||
| BI | 0 | Digital input Term 13 | Parameter 1614 (9.3.1 [101]) | Read | ||
| BI | 1 | Digital input Term 14 | Parameter 1614 (9.3.1 [101]) | Read | ||
| BI | 2 | Digital input Term 15 | Parameter 1614 (9.3.1 [101]) | Read | ||
| BI | 3 | Digital input Term 16 | Parameter 1614 (9.3.1 [101]) | Read | ||
| BI | 4 | Digital input Term 17 | Parameter 1614 (9.3.1 [101]) | Read | ||
| BI | 5 | Digital input Term 18 | Parameter 1614 (9.3.1 [101]) | Read | ||
| BI | 7 | Digital input 1 (T11) | Parameter 1614 (9.3.1 [201]) | Read | ||
| BI | 8 | Digital input 1 (T12) | Parameter 1614 (9.3.1 [201]) | Read | ||
| BI | 9 | Digital input 1 (T13) | Parameter 1614 (9.3.1 [201]) | Read | ||
| BO | 0 | Digital Output Term 15 | Parameter 1615 (9.3.2 [101]) | Write | ||
| BO | 1 | Digital Output Term 15 | Parameter 1615 (9.3.2 [101]) | Write | ||
| BO | 2 | Digital Output 1 (T7) | Parameter 1615 (9.3.2 [201]) | Write | ||
| BO | 3 | Digital Output 2 (T8) | Parameter 1615 (9.3.2 [201]) | Write | ||
| BO | 4 | Relay Output 1 (T5) | Parameter 1615 (9.3.2 [101]) | Write | ||
| BO | 5 | Relay Output 2 (T6) | Parameter 1615 (9.3.2 [101]) | Write | ||
| BO | 6 | Relay Output 1 X101 | Parameter 4909 (9.3.1 [201]) | Write | ||
| BO | 7 | Relay Output 2 X102 | Parameter 4909 (9.3.1 [201]) | Write | ||
| BO | 8 | Relay Output 3 X103 | Parameter 4909 (9.3.1 [201]) | Write | ||
| BVmin | 1 | RUN/STOP Command | Parameter 1335 (5.27.1.42) | Write | ||
| BV | 3 | Fault Reset | Parameter 1307 (5.27.1.50) | Read | ||
| BV | 5 | READY/FAULT Monitor | Parameter 1307 (5.27.1.50) | Read | ||
| BV | 6 | LOCAL/REMOTE | Parameter 1307 (5.27.1.50) | Read | ||
| BVmin | 21 | Warning | Parameter 1307 (5.27.1.50) | Read | ||
| BVmin | 22 | Trip | Parameter 1307 (5.27.1.50) | Read | ||
| BV | 24 | Coasting | Parameter 1335 (5.27.1.42) | Write | ||
| BV | 25 | Reversing (CW/CCW) | Parameter 1335 (5.27.1.42) | Write | ||
| BV | 31 | Speed = reference | Parameter 1307 (5.27.1.50) | Read | ||
| BV | 32 | Bus control | Parameter 1307 (5.27.1.50) | Read | ||
| BVmin | 33 | Running | Parameter 1307 (5.27.1.50) | Read | ||
| BV | 34 | Ramp 1/Ramp 2 | Parameter 1335 (5.27.1.42) | Write | ||
| BV | 41 | Sleep Mode Status | Read | |||
| BV | 44 | Interlock Status | Read | |||
| BV | 47 | End of Curve | Read | |||
| BV | 49 | No Flow | Read | |||
| BV | 50 | Dry Run | Read | |||
| BV | 62 | Fieldbus Status word 1, bit 14 | Parameter 1307 (5.27.1.50) | Read | ||
| BV | 63 | Fieldbus Status word 1, bit 15 | Parameter 1307 (5.27.1.50) | Read | ||
| BV | 64 | Fieldbus Status word 2, bit 0 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 65 | Fieldbus Status word 2, bit 1 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 66 | Fieldbus Status word 2, bit 2 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 67 | Fieldbus Status word 2, bit 3 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 68 | Fieldbus Status word 2, bit 4 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 69 | Fieldbus Status word 2, bit 5 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 70 | Fieldbus Status word 2, bit 6 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 71 | Fieldbus Status word 2, bit 7 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 72 | Fieldbus Status word 2, bit 8 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 73 | Fieldbus Status word 2, bit 9 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 74 | Fieldbus Status word 2, bit 10 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 75 | Fieldbus Status word 2, bit 11 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 76 | Fieldbus Status word 2, bit 12 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 77 | Fieldbus Status word 2, bit 13 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 78 | Fieldbus Status word 2, bit 14 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 79 | Fieldbus Status word 2, bit 15 | Parameter 1344 (5.27.1.90) | Read | ||
| BV | 80 | Fieldbus Control Word 1, bit 12 | Parameter 1335 (5.27.1.42) | Write | ||
| BV | 81 | Fieldbus Control Word 1, bit 13 | Parameter 1335 (5.27.1.42) | Write | ||
| BV | 82 | Fieldbus Control Word 1, bit 14 | Parameter 1335 (5.27.1.42) | Write | ||
| BV | 83 | Fieldbus Control Word 1, bit 15 | Parameter 1335 (5.27.1.42) | Write | ||
| BV | 84 | Fieldbus Control Word 2, bit 0 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 85 | Fieldbus Control Word 2, bit 1 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 86 | Fieldbus Control Word 2, bit 2 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 87 | Fieldbus Control Word 2, bit 3 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 88 | Fieldbus Control Word 2, bit 4 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 89 | Fieldbus Control Word 2, bit 5 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 90 | Fieldbus Control Word 2, bit 6 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 91 | Fieldbus Control Word 2, bit 7 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 92 | Fieldbus Control Word 2, bit 8 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 93 | Fieldbus Control Word 2, bit 9 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 94 | Fieldbus Control Word 2, bit 10 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 95 | Fieldbus Control Word 2, bit 11 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 96 | Fieldbus Control Word 2, bit 12 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 97 | Fieldbus Control Word 2, bit 13 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 98 | Fieldbus Control Word 2, bit 14 | Parameter 1347 (5.27.1.89) | Write | ||
| BV | 99 | Fieldbus Control Word 2, bit 15 | Parameter 1347 (5.27.1.89) | Write |
No points match these filters.
Object ID lookup: Danfoss iC7 Series drives with BACnet/IP or BACnet MS/TP point IDs by name
AI20Analog Input (T33)AI21Analog Input (T34)AI22Analog Input (T2)AI23Analog Input (T3)AI24Temperature Input (T34)AI25Temperature Input 1 (T2)AI26Temperature Input 2 (T3)AO0Analog Output 1 (T31)AO3Analog Output (T4)AV1Fieldbus Speed Reference 1 (Input Reference 1)AV3Motor Speed (Motor Actual Speed)AV5Motor CurrentAV6Output PowerAV7Fieldbus Process ReferenceAV15Motor Thermal Overload (ETR)AV16Line-To-Line Voltage (RMS)AV17L1-L2 Line Voltage (RMS)AV18L2-L3 Line Voltage (RMS)AV19L3-L1 Line Voltage (RMS)AV20Control Unit On TimeAV21Power Unit On TimeAV22Active Running HoursAV23Energy ConsumptionAV24Motor VoltageAV25Output FrequencyAV26TorqueAV27DC Link VoltageAV28Heat Sink TemperatureAV30Multi Zone Reference 1 (Setpoint 1)AV32Feedback 1AV35Multi Zone Reference 2 (Setpoint 2)AV37Feedback 2AV40Multi Zone Reference 3 (Setpoint 3)AV42Feedback 3AV47Control Unit TemperatureAV49Control Place SelectionAV51Occurrence NumberAV52PID Start SpeedAV53On Reference BandwidthAV54PID Proportional GainAV55PID Integral TimeAV56PID Derivative TimeAV57PID Derivative GainAV59Process Controller output (PID Output)AV60ReservedAV61Fault Status Word 1AV66Warning WordAV70FeedbackAV71Converted Signal 1AV72Converted SignalAV77Converted Signal 3AV153MPC StatusAV154Number of Fixed-Speed Pumps RunningAV155Fixed-Speed Pump 1 StatusAV156Fixed-Speed Pump 2 StatusAV157Fixed-Speed Pump 3 StatusAV158Fixed-Speed Pump 4 StatusAV159Fixed-Speed Pump 5 StatusAV163Fixed-Speed Pump 1 Running HoursAV164Fixed-Speed Pump 2 Running HoursAV165Fixed-Speed Pump 3 Running HoursAV166Fixed-Speed Pump 4 Running HoursAV167Fixed-Speed Pump 5 Running HoursAV171Fixed-Speed Pump 1 Number of StartsAV172Fixed-Speed Pump 2 Number of StartsAV173Fixed-Speed Pump 3 Number of StartsAV174Fixed-Speed Pump 4 Number of StartsAV175Fixed-Speed Pump 5 Number of StartsBI0Digital input Term 13BI1Digital input Term 14BI2Digital input Term 15BI3Digital input Term 16BI4Digital input Term 17BI5Digital input Term 18BI7Digital input 1 (T11)BI8Digital input 1 (T12)BI9Digital input 1 (T13)BO0Digital Output Term 15BO1Digital Output Term 15BO2Digital Output 1 (T7)BO3Digital Output 2 (T8)BO4Relay Output 1 (T5)BO5Relay Output 2 (T6)BO6Relay Output 1 X101BO7Relay Output 2 X102BO8Relay Output 3 X103BV1RUN/STOP CommandBV3Fault ResetBV5READY/FAULT MonitorBV6LOCAL/REMOTEBV21WarningBV22TripBV24CoastingBV25Reversing (CW/CCW)BV31Speed = referenceBV32Bus controlBV33RunningBV34Ramp 1/Ramp 2BV41Sleep Mode StatusBV44Interlock StatusBV47End of CurveBV49No FlowBV50Dry RunBV62Fieldbus Status word 1, bit 14BV63Fieldbus Status word 1, bit 15BV64Fieldbus Status word 2, bit 0BV65Fieldbus Status word 2, bit 1BV66Fieldbus Status word 2, bit 2BV67Fieldbus Status word 2, bit 3BV68Fieldbus Status word 2, bit 4BV69Fieldbus Status word 2, bit 5BV70Fieldbus Status word 2, bit 6BV71Fieldbus Status word 2, bit 7BV72Fieldbus Status word 2, bit 8BV73Fieldbus Status word 2, bit 9BV74Fieldbus Status word 2, bit 10BV75Fieldbus Status word 2, bit 11BV76Fieldbus Status word 2, bit 12BV77Fieldbus Status word 2, bit 13BV78Fieldbus Status word 2, bit 14BV79Fieldbus Status word 2, bit 15BV80Fieldbus Control Word 1, bit 12BV81Fieldbus Control Word 1, bit 13BV82Fieldbus Control Word 1, bit 14BV83Fieldbus Control Word 1, bit 15BV84Fieldbus Control Word 2, bit 0BV85Fieldbus Control Word 2, bit 1BV86Fieldbus Control Word 2, bit 2BV87Fieldbus Control Word 2, bit 3BV88Fieldbus Control Word 2, bit 4BV89Fieldbus Control Word 2, bit 5BV90Fieldbus Control Word 2, bit 6BV91Fieldbus Control Word 2, bit 7BV92Fieldbus Control Word 2, bit 8BV93Fieldbus Control Word 2, bit 9BV94Fieldbus Control Word 2, bit 10BV95Fieldbus Control Word 2, bit 11BV96Fieldbus Control Word 2, bit 12BV97Fieldbus Control Word 2, bit 13BV98Fieldbus Control Word 2, bit 14BV99Fieldbus Control Word 2, bit 15
Integration notes
- Taken from section 2.7 BACnet Objects (Tables 9-14) of the iC7 BACnet/IP operating guide; the iC7 BACnet MS/TP operating guide (AQ528743911395en-010101) prints the same 141 objects with the same names and access.
- The description field gives the drive parameter number and index each object maps to, as printed.
- Objects for I/O options (General Purpose I/O, Relay Option, Temperature Measurement OC7T0) and for MPC fixed-speed pumps only carry data when that option or function is used. The AI objects with a custom-unit flag take the unit configured for the input.
- BV 41-50 (sleep, interlock, end of curve, no flow, dry run) are printed without access or parameter; they are listed as read-only.
- BO 0 and BO 1 are both printed as 'Digital Output Term 15'; names kept as printed.
- For AV 1-7 Danfoss prints the same parameter numbers, indexes and remarks as AI 20-24 (an apparent copy error in the guide); they are kept as printed, so don't rely on them.
Check it against the live device. A points list tells you what the controller can expose; the unit in front of you may differ by firmware or installed options. This list is provided as-is for reference only and may contain mistakes — confirming it before you write, map or commission anything is up to you (terms). Easy BACnet scans a network for BACnet IP devices from an Android phone, reads every object on the iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN) and exports what it actually has to Excel — free. New to BACnet? Start with what a BACnet points list is and what the object types mean.
Questions about the Danfoss iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN)
How many BACnet points does the Danfoss iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN) have?
This list has 141 BACnet objects: 7 analog inputs, 2 analog outputs, 59 analog values, 9 binary inputs, 9 binary outputs, 55 binary values. The exact set on a given unit depends on its firmware, installed options and configuration.
Which Danfoss iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN) BACnet points are writable?
54 of the 141 objects accept a write. Points marked Command have a priority array: a write holds until it is released, so release it back to automatic when you are done.
Where is the official Danfoss iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN) BACnet documentation?
The source is iC7 Series BACnet/IP Operating Guide (BACnet/IP OS7BI) (AQ548636302177en-010101 (136R0460)), revision 2026.04, published free by Danfoss at https://assets.danfoss.com/documents/585354/AQ548636302177en-010101.pdf.
What are the minimum BACnet points to integrate the Danfoss iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN)?
Start with BV 1 RUN/STOP Command (Run/stop command (1 = run)); AV 1 Fieldbus Speed Reference 1 (Input Reference 1) (Speed reference, %); AV 30 Multi Zone Reference 1 (Setpoint 1) (Setpoint 1 when the drive runs its own PID); BV 33 Running (Running status); AV 3 Motor Speed (Motor Actual Speed) (Actual motor speed, %); AV 5 Motor Current (Motor current, A); AV 6 Output Power (Output power, kW); BV 22 Trip (Drive tripped); BV 21 Warning (Active warning); AV 61 Fault Status Word 1 (Fault code word).
How do I enable BMS control of the Danfoss iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN)?
Parameter group 5.5 Control Places: Control Place Selection (5.5.2.1, also AV 49) must be Advanced Control or Fieldbus Control, with Fieldbus Speed Reference Source and the Advanced Start/Stop/Coast inputs set to Fieldbus.
Does the Danfoss iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN) need a BACnet heartbeat or have a communication timeout?
BACnet Connection Timeout (10.3.7.2.14, default 60 s, 10-18000 s) watches the fieldbus data. The response (10.3.7.2.16) can be set to info, warning, warning with a switch to the alternative control place (10.3.7.2.15), or fault (ramp then coast, or coast).
How do I check these points on the real iC7 Series drives with BACnet/IP (OS7BI) or BACnet MS/TP (OS7BN)?
Scan the network with a BACnet IP browser such as Easy BACnet, open the device and compare its object list with this table. Anything missing is usually an option that isn't installed or a point that is disabled in the controller's configuration.
More Danfoss BACnet points lists
- Digital valve actuator (AB-QM pressure independent valves)
Danfoss NovoCon S / M / L / XL digital actuator
Danfoss NovoCon S, M, L and XL digital actuators on AB-QM pressure independent control valves, including NovoCon S with the ChangeOver6 valve.
Also known as: NovoCon, NovoCon S, NovoCon M, NovoCon L, NovoCon XL, AB-QM NovoCon, NovoCon ChangeOver6, AI368140926963 - Thermal energy meter (BACnet MS/TP plug-in module)
Danfoss SonoMeter 40 BACnet MS/TP module
Danfoss SonoMeter 40 ultrasonic heat/cooling energy meters fitted with the BACnet MS/TP module.
Also known as: SonoMeter 40, SonoMeter, Sonometer 40 BACnet, Danfoss BACnet MS/TP base module, AQ404134831215 - Variable frequency drive (HVAC)
Danfoss Vacon 100 / 100 FLOW / 100 HVAC internal BACnet (MS/TP and IP)
Vacon 100, Vacon 100 FLOW and Vacon 100 HVAC AC drives using the built-in RS-485 port (BACnet MS/TP) or the built-in Ethernet port (BACnet IP).
Also known as: Vacon 100, Vacon 100 FLOW, Vacon 100 HVAC, Vacon 100 BACnet, DPD00091, AN361179477697 - Variable frequency drive (BACnet option board)
Danfoss Vacon NX OPT-CJ BACnet MS/TP option board
Vacon NXS, NXP and NXL AC drives fitted with the OPT-CJ BACnet MS/TP option board (slot D or E).
Also known as: OPT-CJ, OPTCJ, NXOPTCJ, Vacon NX BACnet, Vacon NXS, Vacon NXP, Vacon NXL, DPD00901 - Variable frequency drive (water / pump)
Danfoss VLT AQUA Drive FC 202 with BACnet/IP MCA 125
Danfoss VLT AQUA Drive FC 202 fitted with the MCA 125 BACnet/IP option card.
Also known as: FC 202, FC202, VLT AQUA Drive, MCA 125, MCA125, 134B1586, VLT BACnet/IP - Variable frequency drive (HVAC)
Danfoss VLT HVAC Drive FC 102 with BACnet/IP MCA 125
Danfoss VLT HVAC Drive FC 102 fitted with the MCA 125 BACnet/IP option card.
Also known as: FC 102, FC102, VLT HVAC Drive, MCA 125, MCA125, 134B1586, VLT BACnet/IP
Source: iC7 Series BACnet/IP Operating Guide (BACnet/IP OS7BI) · AQ548636302177en-010101 (136R0460) · rev. 2026.04. Object names, instances and units are reproduced as published; descriptions are our own.