Water treatment controller · BACnet points list
Marley MarleyGard CD controller (BACnet) BACnet points list
Updated 4 November 2026
The MarleyGard CD is a cooling-tower water treatment controller. It is a BACnet IP device that reports conductivity, pH, ORP, temperatures, water and flow meter totals, flow rates and 4-20 mA inputs for up to four systems, the setpoints and alarm limits, relay states and a large set of alarm flags. Every object in this list is read-only.
This page lists 453 BACnet objects for the Marley MarleyGard CD controller (BACnet) — 0 of them writable — with each object’s type, instance number, name, engineering units and access. It is re-typed from Marley’s own free documentation, linked below.
- Manufacturer
- Marley
- Model
- MarleyGard CD controller (BACnet)
- Equipment
- Water treatment controller
- Equipment type
- Other equipment
- BACnet objects
- 453 (0 writable)
- Transport
- BACnet IP
- Firmware
- JA.12.1 and higher
- Also known as
- MarleyGard CD, MarleyGard, Marley water treatment controller, SPX Cooling, Z1069147
Reference only, provided as-is: verify against Marley’s current documentation and the live device before use. Not official Marley information. Terms of use.
BMS integration notes: Marley MarleyGard CD controller (BACnet)
Treat the MarleyGard CD as a monitoring device: read the chemistry inputs (conductivity, pH, ORP) and the flow switch for each system in use, and map the per-system All Alarms flags (BV 11, 80, 149, 218) as summary alarms.
Minimum points to map
The short list most integrators start with — enough to run the unit from a BMS. Map more as the job needs.
| Object | Name | Why | Access |
|---|---|---|---|
| AI 0 | AI-000 | System 1 conductivity | Read |
| AI 8 | AI-008 | System 1 pH | Read |
| AI 12 | AI-012 | System 1 ORP | Read |
| BI 0 | BI-000 | System 1 flow switch | Read |
| BV 11 | BV-011 | System 1: any active alarm | Read |
Network setup
- BACnet IP only (Annex J), on the same Ethernet port used for the WebAdvantage service.
- Set the device instance in Configure > Network settings > BAC (some versions show DEV); 4194303 means unconfigured. The UDP port (47808) is set on the same screen.
- The BMS must be on the same subnet as the controller, or routing must be set up for BACnet traffic.
- Protocol revision 5, B-ASC; ReadProperty only (DS-RP-B).
Watch out for
- All objects are read-only in this edition; setpoints and limits cannot be changed from the BMS.
- ReadProperty only: no ReadPropertyMultiple or COV, so poll at a modest rate.
- BV 93-133 are missing from the published list.
Marley MarleyGard CD controller (BACnet) BACnet objects
Type: AI, AO, AV, BI, BO, BV, MI/MO/MV (multi-state) · Access: Read read-only, Write writable, Command writable with a priority array.
| Description | States | |||||
|---|---|---|---|---|---|---|
| BImin | 0 | BI-000 | System #1 – Flow Switch | Read | ||
| BI | 1 | BI-001 | System #2 – Flow Switch | Read | ||
| BI | 2 | BI-002 | System #3 – Flow Switch | Read | ||
| BI | 3 | BI-003 | System #4 – Flow Switch | Read | ||
| BV | 0 | BV-000 | System #1 – Conductivity Alarm | Read | ||
| BV | 1 | BV-001 | System #1 – pH Alarm | Read | ||
| BV | 2 | BV-002 | System #1 – ORP Alarm | Read | ||
| BV | 3 | BV-003 | System #1 – S. Temp Alarm | Read | ||
| BV | 4 | BV-004 | System #1 – M. Temp Alarm | Read | ||
| BV | 5 | BV-005 | System #1 – D. Temp Alarm | Read | ||
| BV | 6 | BV-006 | System #1 – Timer 1 Alarm | Read | ||
| BV | 7 | BV-007 | System #1 – Timer 2 Alarm | Read | ||
| BV | 8 | BV-008 | System #1 – Timer 3 Alarm | Read | ||
| BV | 9 | BV-009 | System #1 – Timer 4 Alarm | Read | ||
| BV | 10 | BV-010 | System #1 – Timer 5 Alarm | Read | ||
| BVmin | 11 | BV-011 | System #1 – All Alarms | Read | ||
| BV | 12 | BV-012 | System #1 – Conductivity High Alarm | Read | ||
| BV | 13 | BV-013 | System #1 – Conductivity Low Alarm | Read | ||
| BV | 14 | BV-014 | System #1 – Conductivity Limit Alarm | Read | ||
| BV | 15 | BV-015 | System #1 – pH High Alarm | Read | ||
| BV | 16 | BV-016 | System #1 – pH Low Alarm | Read | ||
| BV | 17 | BV-017 | System #1 – pH Limit Alarm | Read | ||
| BV | 18 | BV-018 | System #1 – ORP High Alarm | Read | ||
| BV | 19 | BV-019 | System #1 – ORP Low Alarm | Read | ||
| BV | 20 | BV-020 | System #1 – ORP Limit Alarm | Read | ||
| BV | 21 | BV-021 | System #1 – S. Temp High Alarm | Read | ||
| BV | 22 | BV-022 | System #1 – S. Temp Low Alarm | Read | ||
| BV | 23 | BV-023 | System #1 – M. Temp High Alarm | Read | ||
| BV | 24 | BV-024 | System #1 – M. Temp Low Alarm | Read | ||
| BV | 25 | BV-025 | System #1 – D. Temp High Alarm | Read | ||
| BV | 26 | BV-026 | System #1 – D. Temp Low Alarm | Read | ||
| BV | 27 | BV-027 | System #1 – No Flow Alarm | Read | ||
| BV | 28 | BV-028 | System #1 – Digital Input 1 Alarm | Read | ||
| BV | 29 | BV-029 | System #1 – Digital Input 2 Alarm | Read | ||
| BV | 30 | BV-030 | System #1 – Digital Input 3 Alarm | Read | ||
| BV | 31 | BV-031 | System #1 – Digital Input 4 Alarm | Read | ||
| BV | 32 | BV-032 | System #1 – Digital Input 5 Alarm | Read | ||
| BV | 33 | BV-033 | System #1 – M. Conductivity Alarm | Read | ||
| BV | 34 | BV-034 | System #1 – M. Conductivity High Alarm | Read | ||
| BV | 35 | BV-035 | System #1 – M. Conductivity Low Alarm | Read | ||
| BV | 36 | BV-036 | System #1 – M. Conductivity Limit Alarm | Read | ||
| BV | 37 | BV-037 | System #1 – Notepad 1 High Alarm | Read | ||
| BV | 38 | BV-038 | System #1 – Notepad 2 High Alarm | Read | ||
| BV | 39 | BV-039 | System #1 – Notepad 3 High Alarm | Read | ||
| BV | 40 | BV-040 | System #1 – Notepad 4 High Alarm | Read | ||
| BV | 41 | BV-041 | System #1 – Notepad 5 High Alarm | Read | ||
| BV | 42 | BV-042 | System #1 – Notepad 6 High Alarm | Read | ||
| BV | 43 | BV-043 | System #1 – Notepad 7 High Alarm | Read | ||
| BV | 44 | BV-044 | System #1 – Notepad 8 High Alarm | Read | ||
| BV | 45 | BV-045 | System #1 – Notepad 9 High Alarm | Read | ||
| BV | 46 | BV-046 | System #1 – Notepad 10 High Alarm | Read | ||
| BV | 47 | BV-047 | System #1 – Notepad 1 Low Alarm | Read | ||
| BV | 48 | BV-048 | System #1 – Notepad 2 Low Alarm | Read | ||
| BV | 49 | BV-049 | System #1 – Notepad 3 Low Alarm | Read | ||
| BV | 50 | BV-050 | System #1 – Notepad 4 Low Alarm | Read | ||
| BV | 51 | BV-051 | System #1 – Notepad 5 Low Alarm | Read | ||
| BV | 52 | BV-052 | System #1 – Notepad 6 Low Alarm | Read | ||
| BV | 53 | BV-053 | System #1 – Notepad 7 Low Alarm | Read | ||
| BV | 54 | BV-054 | System #1 – Notepad 8 Low Alarm | Read | ||
| BV | 55 | BV-055 | System #1 – Notepad 9 Low Alarm | Read | ||
| BV | 56 | BV-056 | System #1 – Notepad 10 Low Alarm | Read | ||
| BV | 57 | BV-057 | System #1 – Notepad 1 Time Alarm | Read | ||
| BV | 58 | BV-058 | System #1 – Notepad 2 Time Alarm | Read | ||
| BV | 59 | BV-059 | System #1 – Notepad 3 Time Alarm | Read | ||
| BV | 60 | BV-060 | System #1 – Notepad 4 Time Alarm | Read | ||
| BV | 61 | BV-061 | System #1 – Notepad 5 Time Alarm | Read | ||
| BV | 62 | BV-062 | System #1 – Notepad 6 Time Alarm | Read | ||
| BV | 63 | BV-063 | System #1 – Notepad 7 Time Alarm | Read | ||
| BV | 64 | BV-064 | System #1 – Notepad 8 Time Alarm | Read | ||
| BV | 65 | BV-065 | System #1 – Notepad 9 Time Alarm | Read | ||
| BV | 66 | BV-066 | System #1 – Notepad 10 Time Alarm | Read | ||
| BV | 67 | BV-067 | System #1 – pH 2 Alarm | Read | ||
| BV | 68 | BV-068 | System #1 – ORP 2 Alarm | Read | ||
| BV | 69 | BV-069 | System #2 – Conductivity Alarm | Read | ||
| BV | 70 | BV-070 | System #2 – pH Alarm | Read | ||
| BV | 71 | BV-071 | System #2 – ORP Alarm | Read | ||
| BV | 72 | BV-072 | System #2 – S. Temp Alarm | Read | ||
| BV | 73 | BV-073 | System #2 – M. Temp Alarm | Read | ||
| BV | 74 | BV-074 | System #2 – D. Temp Alarm | Read | ||
| BV | 75 | BV-075 | System #2 – Timer 1 Alarm | Read | ||
| BV | 76 | BV-076 | System #2 – Timer 2 Alarm | Read | ||
| BV | 77 | BV-077 | System #2 – Timer 3 Alarm | Read | ||
| BV | 78 | BV-078 | System #2 – Timer 4 Alarm | Read | ||
| BV | 79 | BV-079 | System #2 – Timer 5 Alarm | Read | ||
| BV | 80 | BV-080 | System #2 – All Alarms | Read | ||
| BV | 81 | BV-081 | System #2 – Conductivity High Alarm | Read | ||
| BV | 82 | BV-082 | System #2 – Conductivity Low Alarm | Read | ||
| BV | 83 | BV-083 | System #2 – Conductivity Limit Alarm | Read | ||
| BV | 84 | BV-084 | System #2 – pH High Alarm | Read | ||
| BV | 85 | BV-085 | System #2 – pH Low Alarm | Read | ||
| BV | 86 | BV-086 | System #2 – pH Limit Alarm | Read | ||
| BV | 87 | BV-087 | System #2 – ORP High Alarm | Read | ||
| BV | 88 | BV-088 | System #2 – ORP Low Alarm | Read | ||
| BV | 89 | BV-089 | System #2 – ORP Limit Alarm | Read | ||
| BV | 90 | BV-090 | System #2 – S. Temp High Alarm | Read | ||
| BV | 91 | BV-091 | System #2 – S. Temp Low Alarm | Read | ||
| BV | 92 | BV-092 | System #2 – M. Temp High Alarm | Read | ||
| BV | 134 | BV-134 | System #2 – Notepad 9 Time Alarm | Read | ||
| BV | 135 | BV-135 | System #2 – Notepad 10 Time Alarm | Read | ||
| BV | 136 | BV-136 | System #2 – pH 2 Alarm | Read | ||
| BV | 137 | BV-137 | System #2 – ORP 2 Alarm | Read | ||
| BV | 138 | BV-138 | System #3 – Conductivity Alarm | Read | ||
| BV | 139 | BV-139 | System #3 – pH Alarm | Read | ||
| BV | 140 | BV-140 | System #3 – ORP Alarm | Read | ||
| BV | 141 | BV-141 | System #3 – S. Temp Alarm | Read | ||
| BV | 142 | BV-142 | System #3 – M. Temp Alarm | Read | ||
| BV | 143 | BV-143 | System #3 – D. Temp Alarm | Read | ||
| BV | 144 | BV-144 | System #3 – Timer 1 Alarm | Read | ||
| BV | 145 | BV-145 | System #3 – Timer 2 Alarm | Read | ||
| BV | 146 | BV-146 | System #3 – Timer 3 Alarm | Read | ||
| BV | 147 | BV-147 | System #3 – Timer 4 Alarm | Read | ||
| BV | 148 | BV-148 | System #3 – Timer 5 Alarm | Read | ||
| BV | 149 | BV-149 | System #3 – All Alarms | Read | ||
| BV | 150 | BV-150 | System #3 – Conductivity High Alarm | Read | ||
| BV | 151 | BV-151 | System #3 – Conductivity Low Alarm | Read | ||
| BV | 152 | BV-152 | System #3 – Conductivity Limit Alarm | Read | ||
| BV | 153 | BV-153 | System #3 – pH High Alarm | Read | ||
| BV | 154 | BV-154 | System #3 – pH Low Alarm | Read | ||
| BV | 155 | BV-155 | System #3 – pH Limit Alarm | Read | ||
| BV | 156 | BV-156 | System #3 – ORP High Alarm | Read | ||
| BV | 157 | BV-157 | System #3 – ORP Low Alarm | Read | ||
| BV | 158 | BV-158 | System #3 – ORP Limit Alarm | Read | ||
| BV | 159 | BV-159 | System #3 – S. Temp High Alarm | Read | ||
| BV | 160 | BV-160 | System #3 – S. Temp Low Alarm | Read | ||
| BV | 161 | BV-161 | System #3 – M. Temp High Alarm | Read | ||
| BV | 162 | BV-162 | System #3 – M. Temp Low Alarm | Read | ||
| BV | 163 | BV-163 | System #3 – D. Temp High Alarm | Read | ||
| BV | 164 | BV-164 | System #3 – D. Temp Low Alarm | Read | ||
| BV | 165 | BV-165 | System #3 – No Flow Alarm | Read | ||
| BV | 166 | BV-166 | System #3 – Digital Input 1 Alarm | Read | ||
| BV | 167 | BV-167 | System #3 – Digital Input 2 Alarm | Read | ||
| BV | 168 | BV-168 | System #3 – Digital Input 3 Alarm | Read | ||
| BV | 169 | BV-169 | System #3 – Digital Input 4 Alarm | Read | ||
| BV | 170 | BV-170 | System #3 – Digital Input 5 Alarm | Read | ||
| BV | 171 | BV-171 | System #3 – M. Conductivity Alarm | Read | ||
| BV | 172 | BV-172 | System #3 – M. Conductivity High Alarm | Read | ||
| BV | 173 | BV-173 | System #3 – M. Conductivity Low Alarm | Read | ||
| BV | 174 | BV-174 | System #3 – M. Conductivity Limit Alarm | Read | ||
| BV | 175 | BV-175 | System #3 – Notepad 1 High Alarm | Read | ||
| BV | 176 | BV-176 | System #3 – Notepad 2 High Alarm | Read | ||
| BV | 177 | BV-177 | System #3 – Notepad 3 High Alarm | Read | ||
| BV | 178 | BV-178 | System #3 – Notepad 4 High Alarm | Read | ||
| BV | 179 | BV-179 | System #3 – Notepad 5 High Alarm | Read | ||
| BV | 180 | BV-180 | System #3 – Notepad 6 High Alarm | Read | ||
| BV | 181 | BV-181 | System #3 – Notepad 7 High Alarm | Read | ||
| BV | 182 | BV-182 | System #3 – Notepad 8 High Alarm | Read | ||
| BV | 183 | BV-183 | System #3 – Notepad 9 High Alarm | Read | ||
| BV | 184 | BV-184 | System #3 – Notepad 10 High Alarm | Read | ||
| BV | 185 | BV-185 | System #3 – Notepad 1 Low Alarm | Read | ||
| BV | 186 | BV-186 | System #3 – Notepad 2 Low Alarm | Read | ||
| BV | 187 | BV-187 | System #3 – Notepad 3 Low Alarm | Read | ||
| BV | 188 | BV-188 | System #3 – Notepad 4 Low Alarm | Read | ||
| BV | 189 | BV-189 | System #3 – Notepad 5 Low Alarm | Read | ||
| BV | 190 | BV-190 | System #3 – Notepad 6 Low Alarm | Read | ||
| BV | 191 | BV-191 | System #3 – Notepad 7 Low Alarm | Read | ||
| BV | 192 | BV-192 | System #3 – Notepad 8 Low Alarm | Read | ||
| BV | 193 | BV-193 | System #3 – Notepad 9 Low Alarm | Read | ||
| BV | 194 | BV-194 | System #3 – Notepad 10 Low Alarm | Read | ||
| BV | 195 | BV-195 | System #3 – Notepad 1 Time Alarm | Read | ||
| BV | 196 | BV-196 | System #3 – Notepad 2 Time Alarm | Read | ||
| BV | 197 | BV-197 | System #3 – Notepad 3 Time Alarm | Read | ||
| BV | 198 | BV-198 | System #3 – Notepad 4 Time Alarm | Read | ||
| BV | 199 | BV-199 | System #3 – Notepad 5 Time Alarm | Read | ||
| BV | 200 | BV-200 | System #3 – Notepad 6 Time Alarm | Read | ||
| BV | 201 | BV-201 | System #3 – Notepad 7 Time Alarm | Read | ||
| BV | 202 | BV-202 | System #3 – Notepad 8 Time Alarm | Read | ||
| BV | 203 | BV-203 | System #3 – Notepad 9 Time Alarm | Read | ||
| BV | 204 | BV-204 | System #3 – Notepad 10 Time Alarm | Read | ||
| BV | 205 | BV-205 | System #3 – pH 2 Alarm | Read | ||
| BV | 206 | BV-206 | System #3 – ORP 2 Alarm | Read | ||
| BV | 207 | BV-207 | System #4 – Conductivity Alarm | Read | ||
| BV | 208 | BV-208 | System #4 – pH Alarm | Read | ||
| BV | 209 | BV-209 | System #4 – ORP Alarm | Read | ||
| BV | 210 | BV-210 | System #4 – S. Temp Alarm | Read | ||
| BV | 211 | BV-211 | System #4 – M. Temp Alarm | Read | ||
| BV | 212 | BV-212 | System #4 – D. Temp Alarm | Read | ||
| BV | 213 | BV-213 | System #4 – Timer 1 Alarm | Read | ||
| BV | 214 | BV-214 | System #4 – Timer 2 Alarm | Read | ||
| BV | 215 | BV-215 | System #4 – Timer 3 Alarm | Read | ||
| BV | 216 | BV-216 | System #4 – Timer 4 Alarm | Read | ||
| BV | 217 | BV-217 | System #4 – Timer 5 Alarm | Read | ||
| BV | 218 | BV-218 | System #4 – All Alarms | Read | ||
| BV | 219 | BV-219 | System #4 – Conductivity High Alarm | Read | ||
| BV | 220 | BV-220 | System #4 – Conductivity Low Alarm | Read | ||
| BV | 221 | BV-221 | System #4 – Conductivity Limit Alarm | Read | ||
| BV | 222 | BV-222 | System #4 – pH High Alarm | Read | ||
| BV | 223 | BV-223 | System #4 – pH Low Alarm | Read | ||
| BV | 224 | BV-224 | System #4 – pH Limit Alarm | Read | ||
| BV | 225 | BV-225 | System #4 – ORP High Alarm | Read | ||
| BV | 226 | BV-226 | System #4 – ORP Low Alarm | Read | ||
| BV | 227 | BV-227 | System #4 – ORP Limit Alarm | Read | ||
| BV | 228 | BV-228 | System #4 – S. Temp High Alarm | Read | ||
| BV | 229 | BV-229 | System #4 – S. Temp Low Alarm | Read | ||
| BV | 230 | BV-230 | System #4 – M. Temp High Alarm | Read | ||
| BV | 231 | BV-231 | System #4 – M. Temp Low Alarm | Read | ||
| BV | 232 | BV-232 | System #4 – D. Temp High Alarm | Read | ||
| BV | 233 | BV-233 | System #4 – D. Temp Low Alarm | Read | ||
| BV | 234 | BV-234 | System #4 – No Flow Alarm | Read | ||
| BV | 235 | BV-235 | System #4 – Digital Input 1 Alarm | Read | ||
| BV | 236 | BV-236 | System #4 – Digital Input 2 Alarm | Read | ||
| BV | 237 | BV-237 | System #4 – Digital Input 3 Alarm | Read | ||
| BV | 238 | BV-238 | System #4 – Digital Input 4 Alarm | Read | ||
| BV | 239 | BV-239 | System #4 – Digital Input 5 Alarm | Read | ||
| BV | 240 | BV-240 | System #4 – M. Conductivity Alarm | Read | ||
| BV | 241 | BV-241 | System #4 – M. Conductivity High Alarm | Read | ||
| BV | 242 | BV-242 | System #4 – M. Conductivity Low Alarm | Read | ||
| BV | 243 | BV-243 | System #4 – M. Conductivity Limit Alarm | Read | ||
| BV | 244 | BV-244 | System #4 – Notepad 1 High Alarm | Read | ||
| BV | 245 | BV-245 | System #4 – Notepad 2 High Alarm | Read | ||
| BV | 246 | BV-246 | System #4 – Notepad 3 High Alarm | Read | ||
| BV | 247 | BV-247 | System #4 – Notepad 4 High Alarm | Read | ||
| BV | 248 | BV-248 | System #4 – Notepad 5 High Alarm | Read | ||
| BV | 249 | BV-249 | System #4 – Notepad 6 High Alarm | Read | ||
| BV | 250 | BV-250 | System #4 – Notepad 7 High Alarm | Read | ||
| BV | 251 | BV-251 | System #4 – Notepad 8 High Alarm | Read | ||
| BV | 252 | BV-252 | System #4 – Notepad 9 High Alarm | Read | ||
| BV | 253 | BV-253 | System #4 – Notepad 10 High Alarm | Read | ||
| BV | 254 | BV-254 | System #4 – Notepad 1 Low Alarm | Read | ||
| BV | 255 | BV-255 | System #4 – Notepad 2 Low Alarm | Read | ||
| BV | 256 | BV-256 | System #4 – Notepad 3 Low Alarm | Read | ||
| BV | 257 | BV-257 | System #4 – Notepad 4 Low Alarm | Read | ||
| BV | 258 | BV-258 | System #4 – Notepad 5 Low Alarm | Read | ||
| BV | 259 | BV-259 | System #4 – Notepad 6 Low Alarm | Read | ||
| BV | 260 | BV-260 | System #4 – Notepad 7 Low Alarm | Read | ||
| BV | 261 | BV-261 | System #4 – Notepad 8 Low Alarm | Read | ||
| BV | 262 | BV-262 | System #4 – Notepad 9 Low Alarm | Read | ||
| BV | 263 | BV-263 | System #4 – Notepad 10 Low Alarm | Read | ||
| BV | 264 | BV-264 | System #4 – Notepad 1 Time Alarm | Read | ||
| BV | 265 | BV-265 | System #4 – Notepad 2 Time Alarm | Read | ||
| BV | 266 | BV-266 | System #4 – Notepad 3 Time Alarm | Read | ||
| BV | 267 | BV-267 | System #4 – Notepad 4 Time Alarm | Read | ||
| BV | 268 | BV-268 | System #4 – Notepad 5 Time Alarm | Read | ||
| BV | 269 | BV-269 | System #4 – Notepad 6 Time Alarm | Read | ||
| BV | 270 | BV-270 | System #4 – Notepad 7 Time Alarm | Read | ||
| BV | 271 | BV-271 | System #4 – Notepad 8 Time Alarm | Read | ||
| BV | 272 | BV-272 | System #4 – Notepad 9 Time Alarm | Read | ||
| BV | 273 | BV-273 | System #4 – Notepad 10 Time Alarm | Read | ||
| BV | 274 | BV-274 | System #4 – pH 2 Alarm | Read | ||
| BV | 275 | BV-275 | System #4 – ORP 2 Alarm | Read | ||
| BV | 276 | BV-276 | ma Input 1 Alarm | Read | ||
| BV | 277 | BV-277 | ma Input 1 High Alarm | Read | ||
| BV | 278 | BV-278 | ma Input 1 Low Alarm | Read | ||
| BV | 279 | BV-279 | ma Input 2 Alarm | Read | ||
| BV | 280 | BV-280 | ma Input 2 High Alarm | Read | ||
| BV | 281 | BV-281 | ma Input 2 Low Alarm | Read | ||
| BV | 282 | BV-282 | ma Input 3 Alarm | Read | ||
| BV | 283 | BV-283 | ma Input 3 High Alarm | Read | ||
| BV | 284 | BV-284 | ma Input 3 Low Alarm | Read | ||
| BV | 285 | BV-285 | ma Input 4 Alarm | Read | ||
| BV | 286 | BV-286 | ma Input 4 High Alarm | Read | ||
| BV | 287 | BV-287 | ma Input 4 Low Alarm | Read | ||
| BV | 288 | BV-288 | ma Input 5 Alarm | Read | ||
| BV | 289 | BV-289 | ma Input 5 High Alarm | Read | ||
| BV | 290 | BV-290 | ma Input 5 Low Alarm | Read | ||
| BV | 291 | BV-291 | ma Input 6 Alarm | Read | ||
| BV | 292 | BV-292 | ma Input 6 High Alarm | Read | ||
| BV | 293 | BV-293 | ma Input 6 Low Alarm | Read | ||
| BV | 294 | BV-294 | ma Input 7 Alarm | Read | ||
| BV | 295 | BV-295 | ma Input 7 High Alarm | Read | ||
| BV | 296 | BV-296 | ma Input 7 Low Alarm | Read | ||
| BV | 297 | BV-297 | ma Input 8 Alarm | Read | ||
| BV | 298 | BV-298 | ma Input 8 High Alarm | Read | ||
| BV | 299 | BV-299 | ma Input 8 Low Alarm | Read | ||
| AImin | 0 | AI-000 | System #1 – Conductivity | Read | ||
| AI | 1 | AI-001 | System #2 – Conductivity | Read | ||
| AI | 2 | AI-002 | System #3 – Conductivity | Read | ||
| AI | 3 | AI-003 | System #4 – Conductivity | Read | ||
| AI | 4 | AI-004 | System #1 – M. Conductivity | Read | ||
| AI | 5 | AI-005 | System #2 – M. Conductivity | Read | ||
| AI | 6 | AI-006 | System #3 – M. Conductivity | Read | ||
| AI | 7 | AI-007 | System #4 – M. Conductivity | Read | ||
| AImin | 8 | AI-008 | System #1 – pH | Read | ||
| AI | 9 | AI-009 | System #2 – pH | Read | ||
| AI | 10 | AI-010 | System #3 – pH | Read | ||
| AI | 11 | AI-011 | System #4 – pH | Read | ||
| AImin | 12 | AI-012 | System #1 – ORP | Read | ||
| AI | 13 | AI-013 | System #2 – ORP | Read | ||
| AI | 14 | AI-014 | System #3 – ORP | Read | ||
| AI | 15 | AI-015 | System #4 – ORP | Read | ||
| AI | 16 | AI-016 | System #1 – S. Temp | Read | ||
| AI | 17 | AI-017 | System #2 – S. Temp | Read | ||
| AI | 18 | AI-018 | System #3 – S. Temp | Read | ||
| AI | 19 | AI-019 | System #4 – S. Temp | Read | ||
| AI | 20 | AI-020 | System #1 – M. Temp | Read | ||
| AI | 21 | AI-021 | System #2 – M. Temp | Read | ||
| AI | 22 | AI-022 | System #3 – M. Temp | Read | ||
| AI | 23 | AI-023 | System #4 – M. Temp | Read | ||
| AI | 24 | AI-024 | Sys #1 – Water Meter #1 - Total Value | Read | ||
| AI | 25 | AI-025 | Sys #2 – Water Meter #1 - Total Value | Read | ||
| AI | 26 | AI-026 | Sys #3 – Water Meter #1 - Total Value | Read | ||
| AI | 27 | AI-027 | Sys #4 – Water Meter #1 - Total Value | Read | ||
| AI | 28 | AI-028 | Sys #1 – Water Meter #2 - Total Value | Read | ||
| AI | 29 | AI-029 | Sys #2 – Water Meter #2 - Total Value | Read | ||
| AI | 30 | AI-030 | Sys #3 – Water Meter #2 - Total Value | Read | ||
| AI | 31 | AI-031 | Sys #4 – Water Meter #2 - Total Value | Read | ||
| AI | 32 | AI-032 | System #1 – M.Cycles | Read | ||
| AI | 33 | AI-033 | System #2 – M.Cycles | Read | ||
| AI | 34 | AI-034 | System #3 – M.Cycles | Read | ||
| AI | 35 | AI-035 | System #4 – M.Cycles | Read | ||
| AI | 36 | AI-036 | 4-20 mA / 0-5V Input #1 - Value | Read | ||
| AI | 37 | AI-037 | 4-20 mA / 0-5V Input #2 - Value | Read | ||
| AI | 38 | AI-038 | 4-20 mA / 0-5V Input #3 - Value | Read | ||
| AI | 39 | AI-039 | 4-20 mA / 0-5V Input #4 - Value | Read | ||
| AI | 40 | AI-040 | 4-20 mA / 0-5V Input #5 - Value | Read | ||
| AI | 41 | AI-041 | 4-20 mA / 0-5V Input #6 - Value | Read | ||
| AI | 42 | AI-042 | 4-20 mA / 0-5V Input #7 - Value | Read | ||
| AI | 43 | AI-043 | 4-20 mA / 0-5V Input #8 - Value | Read | ||
| AI | 44 | AI-044 | Flow Meter #1 – Total Value | Read | ||
| AI | 45 | AI-045 | Flow Meter #2 – Total Value | Read | ||
| AI | 46 | AI-046 | Flow Meter #3 – Total Value | Read | ||
| AI | 47 | AI-047 | Flow Meter #4 – Total Value | Read | ||
| AI | 48 | AI-048 | Flow Meter #5 – Total Value | Read | ||
| AI | 49 | AI-049 | Flow Meter #6 – Total Value | Read | ||
| AI | 50 | AI-050 | Flow Meter #7 – Total Value | Read | ||
| AI | 51 | AI-051 | Flow Meter #8 – Total Value | Read | ||
| AI | 52 | AI-052 | Flow Meter #9 – Total Value | Read | ||
| AI | 53 | AI-053 | Flow Meter #10 – Total Value | Read | ||
| AI | 54 | AI-054 | Flow Meter #1 – Flow Rate (per MIN) | Read | ||
| AI | 55 | AI-055 | Flow Meter #2 – Flow Rate (per MIN) | Read | ||
| AI | 56 | AI-056 | Flow Meter #3 – Flow Rate (per MIN) | Read | ||
| AI | 57 | AI-057 | Flow Meter #4 – Flow Rate (per MIN) | Read | ||
| AI | 58 | AI-058 | Flow Meter #5 – Flow Rate (per MIN) | Read | ||
| AI | 59 | AI-059 | Flow Meter #6 – Flow Rate (per MIN) | Read | ||
| AI | 60 | AI-060 | Flow Meter #7 – Flow Rate (per MIN) | Read | ||
| AI | 61 | AI-061 | Flow Meter #8 – Flow Rate (per MIN) | Read | ||
| AI | 62 | AI-062 | Flow Meter #9 – Flow Rate (per MIN) | Read | ||
| AI | 63 | AI-063 | Flow Meter #10 – Flow Rate (per MIN) | Read | ||
| AV | 0 | AV-000 | System #1 – Conductivity Setpoint #1 | Read | ||
| AV | 1 | AV-001 | System #2 – Conductivity Setpoint #1 | Read | ||
| AV | 2 | AV-002 | System #3 – Conductivity Setpoint #1 | Read | ||
| AV | 3 | AV-003 | System #4 – Conductivity Setpoint #1 | Read | ||
| AV | 4 | AV-004 | System #1 – Conductivity Setpoint #2 | Read | ||
| AV | 5 | AV-005 | System #2 – Conductivity Setpoint #2 | Read | ||
| AV | 6 | AV-006 | System #3 – Conductivity Setpoint #2 | Read | ||
| AV | 7 | AV-007 | System #4 – Conductivity Setpoint #2 | Read | ||
| AV | 8 | AV-008 | System #1 – Conductivity High Alarm | Read | ||
| AV | 9 | AV-009 | System #2 – Conductivity High Alarm | Read | ||
| AV | 10 | AV-010 | System #3 – Conductivity High Alarm | Read | ||
| AV | 11 | AV-011 | System #4 – Conductivity High Alarm | Read | ||
| AV | 12 | AV-012 | System #1 – Conductivity Low Alarm | Read | ||
| AV | 13 | AV-013 | System #2 – Conductivity Low Alarm | Read | ||
| AV | 14 | AV-014 | System #3 – Conductivity Low Alarm | Read | ||
| AV | 15 | AV-015 | System #4 – Conductivity Low Alarm | Read | ||
| AV | 16 | AV-016 | System #1 – M. Conductivity Setpoint | Read | ||
| AV | 17 | AV-017 | System #2 – M. Conductivity Setpoint | Read | ||
| AV | 18 | AV-018 | System #3 – M. Conductivity Setpoint | Read | ||
| AV | 19 | AV-019 | System #4 – M. Conductivity Setpoint | Read | ||
| AV | 20 | AV-020 | System #1 – M. Conductivity High Alarm | Read | ||
| AV | 21 | AV-021 | System #2 – M. Conductivity High Alarm | Read | ||
| AV | 22 | AV-022 | System #3 – M. Conductivity High Alarm | Read | ||
| AV | 23 | AV-023 | System #4 – M. Conductivity High Alarm | Read | ||
| AV | 24 | AV-024 | System #1 – M. Conductivity Low Alarm | Read | ||
| AV | 25 | AV-025 | System #2 – M. Conductivity Low Alarm | Read | ||
| AV | 26 | AV-026 | System #3 – M. Conductivity Low Alarm | Read | ||
| AV | 27 | AV-027 | System #4 – M. Conductivity Low Alarm | Read | ||
| AV | 28 | AV-028 | System #1 – pH Setpoint #1 | Read | ||
| AV | 29 | AV-029 | System #2 – pH Setpoint #1 | Read | ||
| AV | 30 | AV-030 | System #3 – pH Setpoint #1 | Read | ||
| AV | 31 | AV-031 | System #4 – pH Setpoint #1 | Read | ||
| AV | 32 | AV-032 | System #1 – pH Setpoint #2 | Read | ||
| AV | 33 | AV-033 | System #2 – pH Setpoint #2 | Read | ||
| AV | 34 | AV-034 | System #3 – pH Setpoint #2 | Read | ||
| AV | 35 | AV-035 | System #4 – pH Setpoint #2 | Read | ||
| AV | 36 | AV-036 | System #1 – pH High Alarm | Read | ||
| AV | 37 | AV-037 | System #2 – pH High Alarm | Read | ||
| AV | 38 | AV-038 | System #3 – pH High Alarm | Read | ||
| AV | 39 | AV-039 | System #4 – pH High Alarm | Read | ||
| AV | 40 | AV-040 | System #1 – pH Low Alarm | Read | ||
| AV | 41 | AV-041 | System #2 – pH Low Alarm | Read | ||
| AV | 42 | AV-042 | System #3 – pH Low Alarm | Read | ||
| AV | 43 | AV-043 | System #4 – pH Low Alarm | Read | ||
| AV | 44 | AV-044 | System #1 – ORP Setpoint #1 | Read | ||
| AV | 45 | AV-045 | System #2 – ORP Setpoint #1 | Read | ||
| AV | 46 | AV-046 | System #3 – ORP Setpoint #1 | Read | ||
| AV | 47 | AV-047 | System #4 – ORP Setpoint #1 | Read | ||
| AV | 48 | AV-048 | System #1 – ORP Setpoint #2 | Read | ||
| AV | 49 | AV-049 | System #2 – ORP Setpoint #2 | Read | ||
| AV | 50 | AV-050 | System #3 – ORP Setpoint #2 | Read | ||
| AV | 51 | AV-051 | System #4 – ORP Setpoint #2 | Read | ||
| AV | 52 | AV-052 | System #1 – ORP High Alarm | Read | ||
| AV | 53 | AV-053 | System #2 – ORP High Alarm | Read | ||
| AV | 54 | AV-054 | System #3 – ORP High Alarm | Read | ||
| AV | 55 | AV-055 | System #4 – ORP High Alarm | Read | ||
| AV | 56 | AV-056 | System #1 – ORP Low Alarm | Read | ||
| AV | 57 | AV-057 | System #2 – ORP Low Alarm | Read | ||
| AV | 58 | AV-058 | System #3 – ORP Low Alarm | Read | ||
| AV | 59 | AV-059 | System #4 – ORP Low Alarm | Read | ||
| AV | 60 | AV-060 | System #1 – S. Temp Setpoint | Read | ||
| AV | 61 | AV-061 | System #2 – S. Temp Setpoint | Read | ||
| AV | 62 | AV-062 | System #3 – S. Temp Setpoint | Read | ||
| AV | 63 | AV-063 | System #4 – S. Temp Setpoint | Read | ||
| AV | 64 | AV-064 | System #1 – S. Temp High Alarm | Read | ||
| AV | 65 | AV-065 | System #2 – S. Temp High Alarm | Read | ||
| AV | 66 | AV-066 | System #3 – S. Temp High Alarm | Read | ||
| AV | 67 | AV-067 | System #4 – S. Temp High Alarm | Read | ||
| AV | 68 | AV-068 | System #1 – S. Temp Low Alarm | Read | ||
| AV | 69 | AV-069 | System #2 – S. Temp Low Alarm | Read | ||
| AV | 70 | AV-070 | System #3 – S. Temp Low Alarm | Read | ||
| AV | 71 | AV-071 | System #4 – S. Temp Low Alarm | Read | ||
| AV | 72 | AV-072 | System #1 – M. Temp Setpoint | Read | ||
| AV | 73 | AV-073 | System #2 – M. Temp Setpoint | Read | ||
| AV | 74 | AV-074 | System #3 – M. Temp Setpoint | Read | ||
| AV | 75 | AV-075 | System #4 – M. Temp Setpoint | Read | ||
| AV | 76 | AV-076 | System #1 – M. Temp High Alarm | Read | ||
| AV | 77 | AV-077 | System #2 – M. Temp High Alarm | Read | ||
| AV | 78 | AV-078 | System #3 – M. Temp High Alarm | Read | ||
| AV | 79 | AV-079 | System #4 – M. Temp High Alarm | Read | ||
| AV | 80 | AV-080 | System #1 – M. Temp Low Alarm | Read | ||
| AV | 81 | AV-081 | System #2 – M. Temp Low Alarm | Read | ||
| AV | 82 | AV-082 | System #3 – M. Temp Low Alarm | Read | ||
| AV | 83 | AV-083 | System #4 – M. Temp Low Alarm | Read | ||
| AV | 84 | AV-084 | System #1 – D. Temp Setpoint | Read | ||
| AV | 85 | AV-085 | System #2 – D. Temp Setpoint | Read | ||
| AV | 86 | AV-086 | System #3 – D. Temp Setpoint | Read | ||
| AV | 87 | AV-087 | System #4 – D. Temp Setpoint | Read | ||
| AV | 88 | AV-088 | System #1 – D. Temp High Alarm | Read | ||
| AV | 89 | AV-089 | System #2 – D. Temp High Alarm | Read | ||
| AV | 90 | AV-090 | System #3 – D. Temp High Alarm | Read | ||
| AV | 91 | AV-091 | System #4 – D. Temp High Alarm | Read | ||
| AV | 92 | AV-092 | System #1 – D. Temp Low Alarm | Read | ||
| AV | 93 | AV-093 | System #2 – D. Temp Low Alarm | Read | ||
| AV | 94 | AV-094 | System #3 – D. Temp Low Alarm | Read | ||
| AV | 95 | AV-095 | System #4 – D. Temp Low Alarm | Read | ||
| AV | 96 | AV-096 | System #1 – Flow Switch Conf. | Read | ||
| AV | 97 | AV-097 | System #2 – Flow Switch Conf. | Read | ||
| AV | 98 | AV-098 | System #3 – Flow Switch Conf. | Read | ||
| AV | 99 | AV-099 | System #4 – Flow Switch Conf. | Read | ||
| AV | 100 | AV-100 | mA 1 - Output Value | Read | ||
| AV | 101 | AV-101 | mA 2 - Output Value | Read | ||
| AV | 102 | AV-102 | mA 3 - Output Value | Read | ||
| AV | 103 | AV-103 | mA 4 - Output Value | Read | ||
| AV | 104 | AV-104 | mA 5 - Output Value | Read | ||
| AV | 105 | AV-105 | mA 6 - Output Value | Read | ||
| MV | 0 | MSV-000 | Relay 1 – State | Read | ||
| MV | 1 | MSV-001 | Relay 2 – State | Read | ||
| MV | 2 | MSV-002 | Relay 3 – State | Read | ||
| MV | 3 | MSV-003 | Relay 4 – State | Read | ||
| MV | 4 | MSV-004 | Relay 5 – State | Read | ||
| MV | 5 | MSV-005 | Relay 6 – State | Read | ||
| MV | 6 | MSV-006 | Relay 7 – State | Read | ||
| MV | 7 | MSV-007 | Relay 8 – State | Read | ||
| MV | 8 | MSV-008 | Relay 9 – State | Read | ||
| MV | 9 | MSV-009 | Relay 10 – State | Read | ||
| MV | 10 | MSV-010 | Relay 11 – State | Read | ||
| MV | 11 | MSV-011 | Relay 12 – State | Read | ||
| MV | 12 | MSV-012 | Relay 13 – State | Read | ||
| MV | 13 | MSV-013 | Relay 14 – State | Read | ||
| MV | 14 | MSV-014 | Relay 15 – State | Read | ||
| MV | 15 | MSV-015 | Relay 16 – State | Read | ||
| MV | 16 | MSV-016 | Relay 17 – State | Read | ||
| MV | 17 | MSV-017 | Relay 18 – State | Read | ||
| MV | 18 | MSV-018 | Relay 19 – State | Read | ||
| MV | 19 | MSV-019 | Relay 20 – State | Read |
No points match these filters.
Object ID lookup: Marley MarleyGard CD controller point IDs by name
BI0BI-000BI1BI-001BI2BI-002BI3BI-003BV0BV-000BV1BV-001BV2BV-002BV3BV-003BV4BV-004BV5BV-005BV6BV-006BV7BV-007BV8BV-008BV9BV-009BV10BV-010BV11BV-011BV12BV-012BV13BV-013BV14BV-014BV15BV-015BV16BV-016BV17BV-017BV18BV-018BV19BV-019BV20BV-020BV21BV-021BV22BV-022BV23BV-023BV24BV-024BV25BV-025BV26BV-026BV27BV-027BV28BV-028BV29BV-029BV30BV-030BV31BV-031BV32BV-032BV33BV-033BV34BV-034BV35BV-035BV36BV-036BV37BV-037BV38BV-038BV39BV-039BV40BV-040BV41BV-041BV42BV-042BV43BV-043BV44BV-044BV45BV-045BV46BV-046BV47BV-047BV48BV-048BV49BV-049BV50BV-050BV51BV-051BV52BV-052BV53BV-053BV54BV-054BV55BV-055BV56BV-056BV57BV-057BV58BV-058BV59BV-059BV60BV-060BV61BV-061BV62BV-062BV63BV-063BV64BV-064BV65BV-065BV66BV-066BV67BV-067BV68BV-068BV69BV-069BV70BV-070BV71BV-071BV72BV-072BV73BV-073BV74BV-074BV75BV-075BV76BV-076BV77BV-077BV78BV-078BV79BV-079BV80BV-080BV81BV-081BV82BV-082BV83BV-083BV84BV-084BV85BV-085BV86BV-086BV87BV-087BV88BV-088BV89BV-089BV90BV-090BV91BV-091BV92BV-092BV134BV-134BV135BV-135BV136BV-136BV137BV-137BV138BV-138BV139BV-139BV140BV-140BV141BV-141BV142BV-142BV143BV-143BV144BV-144BV145BV-145BV146BV-146BV147BV-147BV148BV-148BV149BV-149BV150BV-150BV151BV-151BV152BV-152BV153BV-153BV154BV-154BV155BV-155BV156BV-156BV157BV-157BV158BV-158BV159BV-159BV160BV-160BV161BV-161BV162BV-162BV163BV-163BV164BV-164BV165BV-165BV166BV-166BV167BV-167BV168BV-168BV169BV-169BV170BV-170BV171BV-171BV172BV-172BV173BV-173BV174BV-174BV175BV-175BV176BV-176BV177BV-177BV178BV-178BV179BV-179BV180BV-180BV181BV-181BV182BV-182BV183BV-183BV184BV-184BV185BV-185BV186BV-186BV187BV-187BV188BV-188BV189BV-189BV190BV-190BV191BV-191BV192BV-192BV193BV-193BV194BV-194BV195BV-195BV196BV-196BV197BV-197BV198BV-198BV199BV-199BV200BV-200BV201BV-201BV202BV-202BV203BV-203BV204BV-204BV205BV-205BV206BV-206BV207BV-207BV208BV-208BV209BV-209BV210BV-210BV211BV-211BV212BV-212BV213BV-213BV214BV-214BV215BV-215BV216BV-216BV217BV-217BV218BV-218BV219BV-219BV220BV-220BV221BV-221BV222BV-222BV223BV-223BV224BV-224BV225BV-225BV226BV-226BV227BV-227BV228BV-228BV229BV-229BV230BV-230BV231BV-231BV232BV-232BV233BV-233BV234BV-234BV235BV-235BV236BV-236BV237BV-237BV238BV-238BV239BV-239BV240BV-240BV241BV-241BV242BV-242BV243BV-243BV244BV-244BV245BV-245BV246BV-246BV247BV-247BV248BV-248BV249BV-249BV250BV-250BV251BV-251BV252BV-252BV253BV-253BV254BV-254BV255BV-255BV256BV-256BV257BV-257BV258BV-258BV259BV-259BV260BV-260BV261BV-261BV262BV-262BV263BV-263BV264BV-264BV265BV-265BV266BV-266BV267BV-267BV268BV-268BV269BV-269BV270BV-270BV271BV-271BV272BV-272BV273BV-273BV274BV-274BV275BV-275BV276BV-276BV277BV-277BV278BV-278BV279BV-279BV280BV-280BV281BV-281BV282BV-282BV283BV-283BV284BV-284BV285BV-285BV286BV-286BV287BV-287BV288BV-288BV289BV-289BV290BV-290BV291BV-291BV292BV-292BV293BV-293BV294BV-294BV295BV-295BV296BV-296BV297BV-297BV298BV-298BV299BV-299AI0AI-000AI1AI-001AI2AI-002AI3AI-003AI4AI-004AI5AI-005AI6AI-006AI7AI-007AI8AI-008AI9AI-009AI10AI-010AI11AI-011AI12AI-012AI13AI-013AI14AI-014AI15AI-015AI16AI-016AI17AI-017AI18AI-018AI19AI-019AI20AI-020AI21AI-021AI22AI-022AI23AI-023AI24AI-024AI25AI-025AI26AI-026AI27AI-027AI28AI-028AI29AI-029AI30AI-030AI31AI-031AI32AI-032AI33AI-033AI34AI-034AI35AI-035AI36AI-036AI37AI-037AI38AI-038AI39AI-039AI40AI-040AI41AI-041AI42AI-042AI43AI-043AI44AI-044AI45AI-045AI46AI-046AI47AI-047AI48AI-048AI49AI-049AI50AI-050AI51AI-051AI52AI-052AI53AI-053AI54AI-054AI55AI-055AI56AI-056AI57AI-057AI58AI-058AI59AI-059AI60AI-060AI61AI-061AI62AI-062AI63AI-063AV0AV-000AV1AV-001AV2AV-002AV3AV-003AV4AV-004AV5AV-005AV6AV-006AV7AV-007AV8AV-008AV9AV-009AV10AV-010AV11AV-011AV12AV-012AV13AV-013AV14AV-014AV15AV-015AV16AV-016AV17AV-017AV18AV-018AV19AV-019AV20AV-020AV21AV-021AV22AV-022AV23AV-023AV24AV-024AV25AV-025AV26AV-026AV27AV-027AV28AV-028AV29AV-029AV30AV-030AV31AV-031AV32AV-032AV33AV-033AV34AV-034AV35AV-035AV36AV-036AV37AV-037AV38AV-038AV39AV-039AV40AV-040AV41AV-041AV42AV-042AV43AV-043AV44AV-044AV45AV-045AV46AV-046AV47AV-047AV48AV-048AV49AV-049AV50AV-050AV51AV-051AV52AV-052AV53AV-053AV54AV-054AV55AV-055AV56AV-056AV57AV-057AV58AV-058AV59AV-059AV60AV-060AV61AV-061AV62AV-062AV63AV-063AV64AV-064AV65AV-065AV66AV-066AV67AV-067AV68AV-068AV69AV-069AV70AV-070AV71AV-071AV72AV-072AV73AV-073AV74AV-074AV75AV-075AV76AV-076AV77AV-077AV78AV-078AV79AV-079AV80AV-080AV81AV-081AV82AV-082AV83AV-083AV84AV-084AV85AV-085AV86AV-086AV87AV-087AV88AV-088AV89AV-089AV90AV-090AV91AV-091AV92AV-092AV93AV-093AV94AV-094AV95AV-095AV96AV-096AV97AV-097AV98AV-098AV99AV-099AV100AV-100AV101AV-101AV102AV-102AV103AV-103AV104AV-104AV105AV-105MV0MSV-000MV1MSV-001MV2MSV-002MV3MSV-003MV4MSV-004MV5MSV-005MV6MSV-006MV7MSV-007MV8MSV-008MV9MSV-009MV10MSV-010MV11MSV-011MV12MSV-012MV13MSV-013MV14MSV-014MV15MSV-015MV16MSV-016MV17MSV-017MV18MSV-018MV19MSV-019
Integration notes
- Object names are generic (BI-000, BV-011, AI-008 ...); what each object means is in the Purpose column, shown here as the description.
- The setup screen shows an advantagecontrols.com server and the WebAdvantage service, and most object numbers and purposes match Advantage Controls' MegaTron BACnet H22 list, so it looks like a MarleyGard-branded MegaTron (the manual does not say so). This older edition lists fewer objects and marks every one read-only.
- The published PDF repeats page 8 as page 9 and does not print BV 93-133; those objects are not listed here.
- No engineering units or relay state texts are given; values follow the units configured in the controller.
- Most points repeat for System #1 to #4 whether or not those systems are installed.
Check it against the live device. A points list tells you what the controller can expose; the unit in front of you may differ by firmware or installed options. This list is provided as-is for reference only and may contain mistakes — confirming it before you write, map or commission anything is up to you (terms). Easy BACnet scans a network for BACnet IP devices from an Android phone, reads every object on the MarleyGard CD controller (BACnet) and exports what it actually has to Excel — free. New to BACnet? Start with what a BACnet points list is and what the object types mean.
Questions about the Marley MarleyGard CD controller (BACnet)
How many BACnet points does the Marley MarleyGard CD controller (BACnet) have?
This list has 453 BACnet objects: 64 analog inputs, 106 analog values, 4 binary inputs, 259 binary values, 20 multi-state values. The exact set on a given unit depends on its firmware, installed options and configuration.
Which Marley MarleyGard CD controller (BACnet) BACnet points are writable?
None of the listed objects are marked writable in the source documentation.
Where is the official Marley MarleyGard CD controller (BACnet) BACnet documentation?
The source is MarleyGard CD controller supplemental - BACnet Communications user manual (Z1069147), revision 2018-04, published free by Marley at https://spxcooling.com/pdf/Z1069147.pdf.
What are the minimum BACnet points to integrate the Marley MarleyGard CD controller (BACnet)?
Start with AI 0 AI-000 (System 1 conductivity); AI 8 AI-008 (System 1 pH); AI 12 AI-012 (System 1 ORP); BI 0 BI-000 (System 1 flow switch); BV 11 BV-011 (System 1: any active alarm).
How do I check these points on the real MarleyGard CD controller (BACnet)?
Scan the network with a BACnet IP browser such as Easy BACnet, open the device and compare its object list with this table. Anything missing is usually an option that isn't installed or a point that is disabled in the controller's configuration.
More Marley BACnet points lists
Source: MarleyGard CD controller supplemental - BACnet Communications user manual · Z1069147 · rev. 2018-04. Object names, instances and units are reproduced as published; descriptions are our own.