Indoor air quality sensor (PM, TVOC, CO2, temperature, humidity) · BACnet points list
Kaiterra Sensedge SE-100 smart air quality monitor (BACnet IP) BACnet points list
Updated 6 November 2026
The Sensedge monitor serves its readings on BACnet IP (IPv4 and IPv6, UDP 47808) as nine Analog Inputs: PM2.5, PM10, TVOC, temperature, humidity, CO2, an unassigned slot and two sensor-module lifespans. All objects support COV.
This page lists 9 BACnet objects for the Kaiterra Sensedge SE-100 smart air quality monitor (BACnet IP) — 0 of them writable — with each object’s type, instance number, name, engineering units and access. It is re-typed from Kaiterra’s own free documentation, linked below.
- Manufacturer
- Kaiterra
- Model
- Sensedge SE-100 smart air quality monitor (BACnet IP)
- Equipment
- Indoor air quality sensor (PM, TVOC, CO2, temperature, humidity)
- Equipment type
- Thermostats, sensors & meters
- BACnet objects
- 9 (0 writable)
- Transport
- BACnet IP
- Firmware
- 1.15.12
- Default device instance
- User-specified
- Also known as
- Sensedge, SE-100, Kaiterra Sensedge, Sensedge air quality monitor
Reference only, provided as-is: verify against Kaiterra’s current documentation and the live device before use. Not official Kaiterra information. Terms of use.
BMS integration notes: Kaiterra Sensedge SE-100 smart air quality monitor (BACnet IP)
Enable BACnet IP on the monitor, give it a unique device instance, then read CO2, PM2.5, TVOC, temperature and humidity. COV subscriptions are supported.
Minimum points to map
The short list most integrators start with — enough to run the unit from a BMS. Map more as the job needs.
| Object | Name | Why | Access |
|---|---|---|---|
| AI 5 | CO2 | CO2 concentration | Read |
| AI 0 | PM2.5 | PM2.5 concentration | Read |
| AI 2 | TVOC | Total VOC level | Read |
| AI 3 | Temperature | Air temperature | Read |
| AI 4 | Humidity | Relative humidity | Read |
Network setup
- BACnet IP on Ethernet or Wi-Fi, IPv4 and IPv6, UDP port 47808.
- Device instance, name, description and location are writable.
Watch out for
- Two objects share the name 'KM10X Module Lifespan'; map by instance.
- Check the Units property; the PICS does not state default units.
Kaiterra Sensedge SE-100 smart air quality monitor (BACnet IP) BACnet objects
Type: AI, AO, AV, BI, BO, BV, MI/MO/MV (multi-state) · Access: Read read-only, Write writable, Command writable with a priority array.
Note: the source document has no read/write column, so access here is inferred from the object type (inputs read-only, values writable). Confirm on the live controller before writing.
| Description | States | |||||
|---|---|---|---|---|---|---|
| AImin | 0 | PM2.5 | PM2.5 concentration | Read | ||
| AI | 1 | PM10 | PM10 concentration | Read | ||
| AImin | 2 | TVOC | Total VOC | Read | ||
| AImin | 3 | Temperature | Air temperature | Read | ||
| AImin | 4 | Humidity | Relative humidity | Read | ||
| AImin | 5 | CO2 | CO2 concentration | Read | ||
| AI | 6 | Unassigned | Not used | Read | ||
| AI | 7 | KM10X Module Lifespan | Sensor module lifespan | Read | ||
| AI | 8 | KM10X Module Lifespan | Sensor module lifespan (second module) | Read |
No points match these filters.
Object ID lookup: Kaiterra Sensedge SE-100 smart air quality monitor point IDs by name
Integration notes
- The PICS has no access column; all objects are listed as read-only readings (only Units and COV_Increment are writable).
- Units are not given in the PICS; the Units property is writable.
- AI 7 and AI 8 are both printed as 'KM10X Module Lifespan'.
- The PICS marks Analog Inputs as dynamically creatable/deletable; the list printed is the default set.
- BACnet support depends on the Sensedge version and firmware.
- Source: Kaiterra Sensedge BACnet PICS, February 2024.
Check it against the live device. A points list tells you what the controller can expose; the unit in front of you may differ by firmware or installed options. This list is provided as-is for reference only and may contain mistakes — confirming it before you write, map or commission anything is up to you (terms). Easy BACnet scans a network for BACnet IP devices from an Android phone, reads every object on the Sensedge SE-100 smart air quality monitor (BACnet IP) and exports what it actually has to Excel — free. New to BACnet? Start with what a BACnet points list is and what the object types mean.
Questions about the Kaiterra Sensedge SE-100 smart air quality monitor (BACnet IP)
How many BACnet points does the Kaiterra Sensedge SE-100 smart air quality monitor (BACnet IP) have?
This list has 9 BACnet objects: 9 analog inputs. The exact set on a given unit depends on its firmware, installed options and configuration.
Which Kaiterra Sensedge SE-100 smart air quality monitor (BACnet IP) BACnet points are writable?
None of the listed objects are marked writable in the source documentation. The source has no read/write column, so this is inferred from object type.
Where is the official Kaiterra Sensedge SE-100 smart air quality monitor (BACnet IP) BACnet documentation?
The source is Kaiterra Sensedge BACnet Protocol Implementation Conformance Statement (PICS), revision 2024-02-27, published free by Kaiterra at https://support.kaiterra.com/hubfs/CS%20Documentation/Kaiterra%20Sensedge%20BACnet%20Protocol%20Implementation%20Conformance%20Statement%20-%20February%202024.pdf?hsLang=en.
What are the minimum BACnet points to integrate the Kaiterra Sensedge SE-100 smart air quality monitor (BACnet IP)?
Start with AI 5 CO2 (CO2 concentration); AI 0 PM2.5 (PM2.5 concentration); AI 2 TVOC (Total VOC level); AI 3 Temperature (Air temperature); AI 4 Humidity (Relative humidity).
How do I check these points on the real Sensedge SE-100 smart air quality monitor (BACnet IP)?
Scan the network with a BACnet IP browser such as Easy BACnet, open the device and compare its object list with this table. Anything missing is usually an option that isn't installed or a point that is disabled in the controller's configuration.
More Kaiterra BACnet points lists
Source: Kaiterra Sensedge BACnet Protocol Implementation Conformance Statement (PICS) · rev. 2024-02-27. Object names, instances and units are reproduced as published; descriptions are our own.