  4. PMC-53A multifunction panel meter, BACnet MS/TP

Energy meter (multifunction panel meter) · BACnet points list

CET Electric PMC-53A multifunction panel meter, BACnet MS/TP BACnet points list

Updated 12 November 2026

Short answer

The PMC-53A is the serial-port multifunction panel meter in CET's PMC-53A family, with BACnet MS/TP from firmware V1.00.03. It uses the same register-number instance scheme as the PMC-53A-E but prints different object names (Uan, Ubn, Ucn ...) and adds DI5-DI6, DO3-DO4 and their counters.

This page lists 128 BACnet objects for the CET Electric PMC-53A multifunction panel meter, BACnet MS/TP — 26 of them writable — with each object’s type, instance number, name, engineering units and access. It is re-typed from CET Electric’s own free documentation, linked below.

Manufacturer
CET Electric
Model
PMC-53A multifunction panel meter, BACnet MS/TP
Equipment
Energy meter (multifunction panel meter)
Equipment type
Thermostats, sensors & meters
BACnet objects
128 (26 writable)
Transport
BACnet MS/TP
Firmware
V1.00.03 or later
Default device instance
26001
Also known as
PMC-53A, PMC53A, CET PMC-53A
Source document
PMC-53A User Manual, Appendix C BACnet MS/TP Implementation · V2.2 · rev. 2026-02-04
Download CSV 128 rows Download EDE B.I.G.-EU JSON Manufacturer PDF ↗ Compare with your scan Download Easy BACnet Mobile App Google Play

Reference only, provided as-is: verify against CET Electric’s current documentation and the live device before use. Not official CET Electric information. Terms of use.

BMS integration notes: CET Electric PMC-53A multifunction panel meter, BACnet MS/TP

Integration in brief

Set the PMC-53A protocol to BACnet MS/TP with a MAC address and baud rate, then read power, energy, voltages and currents. Set PT/CT ratios and wiring mode first if the BMS manages setup.

Minimum points to map

The short list most integrators start with — enough to run the unit from a BMS. Map more as the job needs.

ObjectNameWhyAccess
AI 30P TotalTotal active power, kWRead
AI 500kWh ImportEnergy imported, kWhRead
AI 502kWh ExportEnergy exported, kWhRead
AI 14ULL averageAverage line-line voltage, VRead
AI 22I averageAverage current, ARead
AI 54PF TotalTotal power factorRead
AI 56FrequencyFrequency, HzRead

Network setup

Watch out for

CET Electric PMC-53A multifunction panel meter, BACnet MS/TP BACnet objects

Type: AI, AO, AV, BI, BO, BV, MI/MO/MV (multi-state) · Access: Read read-only, Write writable, Command writable with a priority array.

128 of 128 shown
Type
Access
Show
CET Electric PMC-53A multifunction panel meter, BACnet MS/TP BACnet Points List
DescriptionStates
AI0UanVRead
AI2UbnVRead
AI4UcnVRead
AI6ULN averageVRead
AI8UabVRead
AI10UbcVRead
AI12UcaVRead
AImin14ULL averageVRead
AI16IaARead
AI18IbARead
AI20IcARead
AImin22I averageARead
AI24PakWRead
AI26PbkWRead
AI28PckWRead
AImin30P TotalkWRead
AI32QakvarRead
AI34QbkvarRead
AI36QckvarRead
AI38Q TotalkvarRead
AI40SakVARead
AI42SbkVARead
AI44SckVARead
AI46S TotalkVARead
AI48PFaRead
AI50PFbRead
AI52PFcRead
AImin54PF TotalRead
AImin56FrequencyHzRead
AI70InARead
AI72I4 (Optional Measurement)(optional measurement)ARead
AI82AIRead
AI86RTD1°CRead
AI88RTD2°CRead
AI90AO1Read
AI92AO2Read
AI174IrARead
AImin500kWh ImportkWhRead
AImin502kWh ExportkWhRead
AI504kWh NetkWhRead
AI506kWh TotalkWhRead
AI508kvarh ImportkvarhRead
AI510kvarh ExportkvarhRead
AI512kvarh NetkvarhRead
AI514kvarh TotalkvarhRead
AI516kVAhkVAhRead
AI3006P Total DemandkWRead
AI3008Q Total DemandkvarRead
AI3010S Total DemandkVARead
AI3000Ia DemandARead
AI3002Ib DemandARead
AI3004Ic DemandARead
AI3418P Total Max. DemandkWRead
AI3424Q Total Max. DemandkvarRead
AI3430S Total Max. DemandkVARead
AI3400Ia Max. DemandARead
AI3406Ib Max. DemandARead
AI3412Ic Max. DemandARead
AI1600Uan THD%Read
AI1602Ubn THD%Read
AI1604Ucn THD%Read
AI1400Ia THD%Read
AI1402Ib THD%Read
AI1404Ic THD%Read
AI1318Ia K-FactorRead
AI1320Ib K-FactorRead
AI1322Ic K-FactorRead
AI1300Ia TDD%Read
AI1302Ib TDD%Read
AI1304Ic TDD%Read
AI1324Ia Crest FactorRead
AI1326Ib Crest FactorRead
AI1328Ic Crest FactorRead
AI1330U Unbalance%Read
AI1332I Unbalance%Read
AI74dPFaRead
AI76dPFbRead
AI78dPFcRead
AI58Uan Angle°Read
AI60Ubn Angle°Read
AI62Ucn Angle°Read
AI64Ia Angle°Read
AI66Ib Angle°Read
AI68Ic Angle°Read
AI104Operating TimehRead
AI526Interval kWh ImportkWhRead
AI528Interval kWh ExportkWhRead
AI530Interval kvarh ImportkvarhRead
AI532Interval kvarh ExportkvarhRead
AI534Interval kVAhkVAhRead
AI1200DI1 CounterRead
AI1202DI2 CounterRead
AI1204DI3 CounterRead
AI1206DI4 CounterRead
AI1208DI5 CounterRead
AI1210DI6 CounterRead
AV6000PT Primary High#Range 0 to 1000 kV, default 0kVWrite
AV6001PT Primary Low#Range 1 to 999 V, default 100VWrite
AV6002PT Secondary#Range 1 to 690, default 100Write
AV6004CT PrimaryRange 1 to 30000, default 5Write
AV6006CT SecondaryRange 1 to 5, default 5Write
AV6012I4 PrimaryRange 1 to 30000, default 5Write
AV6014I4 SecondaryRange 1 to 5, default 5Write
AV6020Wiring ModeSetting, default 5Write0=DEMO, 1=1P2W L-N, 2=1P2W L-L, 3=1P3W L-L-N, 4=3P3W, 5=3P4W
AV6021PF ConventionSetting, default 0Write0=IEC, 1=IEEE, 2=-IEEE
AV6022kVA CalculationSetting, default 0Write0=Vector, 1=Scalar
AV6028THD CalculationSetting, default 0Write0=THDf, 1=THDr
AV6029Demand PeriodRange 1 to 60 min, default 15minWrite
AV6030Number of Sliding WindowsRange 1 to 15, default 1Write
AV6047Interval Energy PeriodRange 5 to 60 min, default 60minWrite
AV9603Clear Present Max. DemandWrite 65280 (0xFF00) to clearWrite
AV9601Clear EnergyWrite 65280 (0xFF00) to clearWrite
AV9610Clear DI1 CounterWrite 65280 (0xFF00) to clearWrite
AV9611Clear DI2 CounterWrite 65280 (0xFF00) to clearWrite
AV9612Clear DI3 CounterWrite 65280 (0xFF00) to clearWrite
AV9613Clear DI4 CounterWrite 65280 (0xFF00) to clearWrite
AV9614Clear DI5 CounterWrite 65280 (0xFF00) to clearWrite
AV9615Clear DI6 CounterWrite 65280 (0xFF00) to clearWrite
BI0DI1Digital input statusRead0=Inactive, 1=Active
BI1DI2Digital input statusRead0=Inactive, 1=Active
BI2DI3Digital input statusRead0=Inactive, 1=Active
BI3DI4Digital input statusRead0=Inactive, 1=Active
BI4DI5Digital input statusRead0=Inactive, 1=Active
BI5DI6Digital input statusRead0=Inactive, 1=Active
BO0DO1Digital outputWrite0=Inactive, 1=Active
BO1DO2Digital outputWrite0=Inactive, 1=Active
BO2DO3Digital outputWrite0=Inactive, 1=Active
BO3DO4Digital outputWrite0=Inactive, 1=Active
Object ID lookup: CET Electric PMC-53A multifunction panel meter, BACnet MS/TP point IDs by name

Integration notes

Check it against the live device. A points list tells you what the controller can expose; the unit in front of you may differ by firmware or installed options. This list is provided as-is for reference only and may contain mistakes — confirming it before you write, map or commission anything is up to you (terms). Easy BACnet scans a network for BACnet IP devices from an Android phone, reads every object on the PMC-53A multifunction panel meter, BACnet MS/TP and exports what it actually has to Excel — free. New to BACnet? Start with what a BACnet points list is and what the object types mean.

Questions about the CET Electric PMC-53A multifunction panel meter, BACnet MS/TP

How many BACnet points does the CET Electric PMC-53A multifunction panel meter, BACnet MS/TP have?

This list has 128 BACnet objects: 96 analog inputs, 22 analog values, 6 binary inputs, 4 binary outputs. The exact set on a given unit depends on its firmware, installed options and configuration.

Which CET Electric PMC-53A multifunction panel meter, BACnet MS/TP BACnet points are writable?

26 of the 128 objects accept a write. Points marked Command have a priority array: a write holds until it is released, so release it back to automatic when you are done.

Where is the official CET Electric PMC-53A multifunction panel meter, BACnet MS/TP BACnet documentation?

The source is PMC-53A User Manual, Appendix C BACnet MS/TP Implementation (V2.2), revision 2026-02-04, published free by CET Electric at https://www.cet-global.com/uploadfiles/2026/02/PMC-53A%20User%20Manual%20V2.2%20(20260204).pdf.

What are the minimum BACnet points to integrate the CET Electric PMC-53A multifunction panel meter, BACnet MS/TP?

Start with AI 30 P Total (Total active power, kW); AI 500 kWh Import (Energy imported, kWh); AI 502 kWh Export (Energy exported, kWh); AI 14 ULL average (Average line-line voltage, V); AI 22 I average (Average current, A); AI 54 PF Total (Total power factor); AI 56 Frequency (Frequency, Hz).

How do I check these points on the real PMC-53A multifunction panel meter, BACnet MS/TP?

Scan the network with a BACnet IP browser such as Easy BACnet, open the device and compare its object list with this table. Anything missing is usually an option that isn't installed or a point that is disabled in the controller's configuration.

More CET Electric BACnet points lists

Source: PMC-53A User Manual, Appendix C BACnet MS/TP Implementation · V2.2 · rev. 2026-02-04. Object names, instances and units are reproduced as published; descriptions are our own.