 "manufacturer": "Contemporary Controls",
 "manufacturer_slug": "contemporary-controls",
 "model": "Schneider Electric PowerLogic PM800 via BASgatewayLX",
 "short_model": "BASgatewayLX PowerLogic PM800",
 "model_slug": "basgatewaylx-schneider-pm800",
 "aliases": [
  "PM800",
  "PM810",
  "PM820",
  "PM850",
  "PM870",
  "PowerLogic PM800"
 ],
 "equipment_type": "Power and energy meter",
 "applies_to": "Schneider Electric PowerLogic PM800-series power meters on Modbus, read by a BASgatewayLX.",
 "summary": "Gateway profile for the PowerLogic PM800: 126 Analog Inputs, 44 polled by default. Polled values cover phase, neutral and ground currents, voltages, real/reactive/apparent power per phase and total, true PF, frequency and real, reactive, apparent and conditional energy.",
 "bacnet_transport": [
  "BACnet IP"
 ],
 "firmware": null,
 "default_device_instance": null,
 "access_inferred": true,
 "notes": [
  "Built from Contemporary Controls' BASgatewayLX Modbus device profile Schneider_Electric__PM800_Meter_aLX.csv; the profile maps the registers in the maker's Modbus register document (https://www.ccontrols.com/support/dp/PM800.pdf).",
  "Object instances are the ones this profile assigns when it is loaded into the gateway. A site that edited or rebuilt the profile may use different instances.",
  "Only 44 of the 126 rows are flagged for polling in the profile; the rest are served only after you tick them in the gateway. Their descriptions say \"not polled by default\".",
  "The CSV has no read/write column: Analog/Binary Inputs are read-only and Analog/Binary Outputs are commandable (priority array), which is how the gateway maps them (access inferred). Descriptions give the Modbus register each object reads.",
  "Some names appear more than once in the profile as published (Energy Real Total (signed/absolute); Energy Reactive Total (signed/absolute); Energy Apparent...); they are kept as printed and told apart by instance."
 ],
 "source": {
  "title": "BASgatewayLX Modbus device profile Schneider_Electric__PM800_Meter",
  "doc_number": "Schneider_Electric__PM800_Meter_aLX.csv",
  "revision_date": null,
  "url": "https://www.ccontrols.com/support/dp/Schneider_Electric__PM800_Meter.zip"
 },
 "integration": {
  "summary": "Map real power total, real energy in and voltage L-L average first. The listed objects are read-only.",
  "minimum_points": [
   {
    "ref": "AI 24",
    "name": "Real Power Total",
    "why": "Real power total"
   },
   {
    "ref": "AI 38",
    "name": "Energy Real In",
    "why": "Real energy in"
   },
   {
    "ref": "AI 15",
    "name": "Voltage L-L Average",
    "why": "Voltage L-L average"
   },
   {
    "ref": "AI 11",
    "name": "Current 3-Phase Average",
    "why": "Current 3-phase average"
   },
   {
    "ref": "AI 36",
    "name": "True Power Factor Total",
    "why": "True power factor total"
   },
   {
    "ref": "AI 37",
    "name": "Frequency",
    "why": "Frequency"
   }
  ],
  "enable": null,
  "heartbeat": null,
  "remote_sensors": null,
  "setup": [
   "The BASgatewayLX presents each Modbus device as its own virtual BACnet device on BACnet IP; give it a unique device instance and Modbus address (serial) or IP address (Modbus TCP) when you add it with this profile.",
   "One BASgatewayLX handles up to 100 Modbus devices and 1000 polled points in total, so leave unneeded rows unpolled."
  ],
  "gotchas": [
   "Unpolled rows do not appear as BACnet objects until enabled in the gateway's device profile page."
  ]
 },
 "points": [
  {
   "type": "AI",
   "instance": 1,
   "name": "Energy Real Total (signed/absolute)",
   "description": "Modbus 402600; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 2,
   "name": "Energy Reactive Total (signed/absolute)",
   "description": "Modbus 402602; not polled by default",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 3,
   "name": "Energy Apparent",
   "description": "Modbus 402604; not polled by default",
   "units": "VA",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 4,
   "name": "True Power Factor Total",
   "description": "Modbus 402606; not polled by default",
   "units": "PF",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 5,
   "name": "Display 1 Second Metering Floating Point Values",
   "description": "Modbus 403248; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 6,
   "name": "Current Phase A",
   "description": "Modbus 411700",
   "units": "A",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 7,
   "name": "Current Phase B",
   "description": "Modbus 411702",
   "units": "A",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 8,
   "name": "Current Phase C",
   "description": "Modbus 411704",
   "units": "A",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 9,
   "name": "Current Neutral",
   "description": "Modbus 411706",
   "units": "A",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 10,
   "name": "Current Ground",
   "description": "Modbus 411708",
   "units": "A",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 11,
   "name": "Current 3-Phase Average",
   "description": "Modbus 411710",
   "units": "A",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 12,
   "name": "Voltage A-B",
   "description": "Modbus 411712",
   "units": "V",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 13,
   "name": "Voltage B-C",
   "description": "Modbus 411714",
   "units": "V",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 14,
   "name": "Voltage C-A",
   "description": "Modbus 411716",
   "units": "V",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 15,
   "name": "Voltage L-L Average",
   "description": "Modbus 411718",
   "units": "V",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 16,
   "name": "Voltage A-N",
   "description": "Modbus 411720",
   "units": "V",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 17,
   "name": "Voltage B-N",
   "description": "Modbus 411722",
   "units": "V",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 18,
   "name": "Voltage C-N",
   "description": "Modbus 411724",
   "units": "V",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 19,
   "name": "Voltage N-G",
   "description": "Modbus 411726",
   "units": "V",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 20,
   "name": "Voltage L-N Average",
   "description": "Modbus 411728",
   "units": "V",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 21,
   "name": "Real Power Phase A",
   "description": "Modbus 411730",
   "units": "W",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 22,
   "name": "Real Power Phase B",
   "description": "Modbus 411732",
   "units": "W",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 23,
   "name": "Real Power Phase C",
   "description": "Modbus 411734",
   "units": "W",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 24,
   "name": "Real Power Total",
   "description": "Modbus 411736",
   "units": "W",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 25,
   "name": "Reactive Power Phase A",
   "description": "Modbus 411738",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 26,
   "name": "Reactive Power Phase B",
   "description": "Modbus 411740",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 27,
   "name": "Reactive Power Phase C",
   "description": "Modbus 411742",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 28,
   "name": "Reactive Power Total",
   "description": "Modbus 411744",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 29,
   "name": "Apparent Power Phase A",
   "description": "Modbus 411746",
   "units": "VA",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 30,
   "name": "Apparent Power Phase B",
   "description": "Modbus 411748",
   "units": "VA",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 31,
   "name": "Apparent Power Phase C",
   "description": "Modbus 411750",
   "units": "VA",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 32,
   "name": "Apparent Power Total",
   "description": "Modbus 411752",
   "units": "VA",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 33,
   "name": "True Power Factor Phase A",
   "description": "Modbus 411754",
   "units": "PF",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 34,
   "name": "True Power Factor Phase B",
   "description": "Modbus 411756",
   "units": "PF",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 35,
   "name": "True Power Factor Phase C",
   "description": "Modbus 411758",
   "units": "PF",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 36,
   "name": "True Power Factor Total",
   "description": "Modbus 411760",
   "units": "PF",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 37,
   "name": "Frequency",
   "description": "Modbus 411762",
   "units": "Hz",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 38,
   "name": "Energy Real In",
   "description": "Modbus 411800",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 39,
   "name": "Energy Reactive In",
   "description": "Modbus 411802",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 40,
   "name": "Energy Real Out",
   "description": "Modbus 411804",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 41,
   "name": "Energy Reactive Out",
   "description": "Modbus 411806",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 42,
   "name": "Energy Real Total (signed/absolute)",
   "description": "Modbus 411808",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 43,
   "name": "Energy Reactive Total (signed/absolute)",
   "description": "Modbus 411810",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 44,
   "name": "Energy Apparent",
   "description": "Modbus 411812",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 45,
   "name": "Energy Conditional Real In",
   "description": "Modbus 411814",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 46,
   "name": "Energy Conditional Reactive In",
   "description": "Modbus 411816",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 47,
   "name": "Energy Conditional Real Out",
   "description": "Modbus 411818",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 48,
   "name": "Energy Conditional Reactive Out",
   "description": "Modbus 411820",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 49,
   "name": "Energy Conditional Apparent",
   "description": "Modbus 411822",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 50,
   "name": "Energy Incremental Real In Last Complete Interval",
   "description": "Modbus 411824; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 51,
   "name": "Energy. Incremental Reactive In Last Complete Interval",
   "description": "Modbus 411826; not polled by default",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 52,
   "name": "Energy Incremental Real Out Last Complete Interval",
   "description": "Modbus 411828; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 53,
   "name": "Energy Incremental Reactive Out Last Complete Interval",
   "description": "Modbus 411830; not polled by default",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 54,
   "name": "Energy Incremental Apparent Last Complete Interval",
   "description": "Modbus 411832; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 55,
   "name": "Energy Incremental Real In Present interval",
   "description": "Modbus 411836; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 56,
   "name": "Energy. Incremental Reactive In Present Interval",
   "description": "Modbus 411838; not polled by default",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 57,
   "name": "Energy Incremental Real Out Present Interval",
   "description": "Modbus 411840; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 58,
   "name": "Energy Incremental Reactive Out Present Interval",
   "description": "Modbus 411842; not polled by default",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 59,
   "name": "Energy Incremental Apparent Present Interval",
   "description": "Modbus 411844; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 60,
   "name": "Energy Reactive Quadrant 1",
   "description": "Modbus 411846; not polled by default",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 61,
   "name": "Energy Reactive Quadrant 2",
   "description": "Modbus 411848; not polled by default",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 62,
   "name": "Energy Reactive Quadrant 3",
   "description": "Modbus 411850; not polled by default",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 63,
   "name": "Energy Reactive Quadrant 4",
   "description": "Modbus 411852; not polled by default",
   "units": "VAR",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 64,
   "name": "Cumulative Usage Input Channel #1",
   "description": "Modbus 411854; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 65,
   "name": "Cumulative Usage Input Channel #2",
   "description": "Modbus 411856; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 66,
   "name": "Cumulative Usage Input Channel #3",
   "description": "Modbus 411858; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 67,
   "name": "Cumulative Usage Input Channel #4",
   "description": "Modbus 411860; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 68,
   "name": "Cumulative Usage Input Channel #5",
   "description": "Modbus 411862; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 69,
   "name": "Energy Real 3-Phase Total Usage Today",
   "description": "Modbus 411864; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 70,
   "name": "Energy Real 3-Phase Total Usage Yesterday",
   "description": "Modbus 411866; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 71,
   "name": "Energy Real 3-Phase Total Usage This Week",
   "description": "Modbus 411868; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 72,
   "name": "Energy Real 3-Phase Total Usage Last Week",
   "description": "Modbus 411870; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 73,
   "name": "Energy Real 3-Phase Total Usage This Month",
   "description": "Modbus 411872; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 74,
   "name": "Energy Real 3-Phase Total Usage Last Month",
   "description": "Modbus 411874; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 75,
   "name": "Energy Apparent 3-Phase Total Usage Today",
   "description": "Modbus 411876; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 76,
   "name": "Energy Apparent 3-Phase Total Usage Yesterday",
   "description": "Modbus 411878; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 77,
   "name": "Energy Apparent 3-Phase Total Usage This Week",
   "description": "Modbus 411880; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 78,
   "name": "Energy Apparent 3-Phase Total Usage Last Week",
   "description": "Modbus 411882; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 79,
   "name": "Energy Apparent 3-Phase Total Usage This Month",
   "description": "Modbus 411884; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 80,
   "name": "Energy Apparent 3-Phase Total Usage Last Month",
   "description": "Modbus 411886; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 81,
   "name": "Energy Real 3-Phase Total Usage – First Shift – Today",
   "description": "Modbus 411888; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 82,
   "name": "Energy Real 3-Phase Total Usage – Second Shift – Today",
   "description": "Modbus 411890; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 83,
   "name": "Energy Real 3-Phase Total Usage – Third Shift – Today",
   "description": "Modbus 411892; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 84,
   "name": "Energy Real 3-Phase Total Usage – First Shift – Yesterday",
   "description": "Modbus 411894; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 85,
   "name": "Energy Real 3-Phase Total Usage – Second Shift – Yesterday",
   "description": "Modbus 411896; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 86,
   "name": "Energy Real 3-Phase Total Energy Real 3-Phase Total",
   "description": "Modbus 411898; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 87,
   "name": "Energy Real 3-Phase Total Usage – First Shift – This Week",
   "description": "Modbus 411900; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 88,
   "name": "Energy Real 3-Phase Total Usage – Second Shift – This Week",
   "description": "Modbus 411902; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 89,
   "name": "Energy Real 3-Phase Total Usage – Third Shift – This Week",
   "description": "Modbus 411904; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 90,
   "name": "Energy Real 3-Phase Total Usage – First Shift – Last Week",
   "description": "Modbus 411906; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 91,
   "name": "Energy Real 3-Phase Total Usage – Second Shift – Last Week",
   "description": "Modbus 411908; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 92,
   "name": "Energy Real 3-Phase Total Usage – Third Shift – Last Week",
   "description": "Modbus 411910; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 93,
   "name": "Energy Real 3-Phase Total Usage – First Shift – This Month",
   "description": "Modbus 411912; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 94,
   "name": "Energy Real 3-Phase Total Usage – Second Shift – This Month",
   "description": "Modbus 411914; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 95,
   "name": "Energy Real 3-Phase Total Usage – Third Shift – This Month",
   "description": "Modbus 411916; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 96,
   "name": "Energy Real 3-Phase Total Usage – First Shift – Last Month",
   "description": "Modbus 411918; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 97,
   "name": "Energy Real 3-Phase Total Usage – Second Shift – Last Month",
   "description": "Modbus 411920; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 98,
   "name": "Energy Real 3-Phase Total Usage – Third Shift – Last Month",
   "description": "Modbus 411922; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 99,
   "name": "Energy Apparent 3-Phase Total Usage – First Shift – Today",
   "description": "Modbus 411924; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 100,
   "name": "Energy Apparent 3-Phase Total Usage – Second Shift – Today",
   "description": "Modbus 411926; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 101,
   "name": "Energy Apparent 3-Phase Total Usage – Third Shift – Today",
   "description": "Modbus 411928; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 102,
   "name": "Energy Apparent 3-Phase Total Usage – First Shift – Yesterday",
   "description": "Modbus 411930; not polled by default",
   "units": "Wh",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 103,
   "name": "Energy Apparent 3-Phase Total Usage – Second Shift – Yesterday",
   "description": "Modbus 411932; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 104,
   "name": "Energy Apparent 3-Phase Total Usage – Third Shift – Yesterday",
   "description": "Modbus 411934; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 105,
   "name": "Energy Apparent 3-Phase Total Usage – First Shift – This Week",
   "description": "Modbus 411936; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 106,
   "name": "Energy Apparent 3-Phase Total Usage – Second Shift – This Week",
   "description": "Modbus 411938; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 107,
   "name": "Energy Apparent 3-Phase Total Usage – Third Shift – This Week",
   "description": "Modbus 411940; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 108,
   "name": "Energy Apparent 3-Phase Total Usage – First Shift – Last Week",
   "description": "Modbus 411942; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 109,
   "name": "Energy Apparent 3-Phase Total Usage – Second Shift – Last Week",
   "description": "Modbus 411944; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 110,
   "name": "Energy Apparent 3-Phase Total Usage – Third Shift – Last Week",
   "description": "Modbus 411946; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 111,
   "name": "Energy Apparent 3-Phase Total Usage – First Shift – This Month",
   "description": "Modbus 411948; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 112,
   "name": "Energy Apparent 3-Phase Total Usage – Second Shift – This Month",
   "description": "Modbus 411950; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 113,
   "name": "Energy Apparent 3-Phase Total Energy Apparent 3-Phase Total",
   "description": "Modbus 411952; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 114,
   "name": "Energy Apparent 3-Phase Total Usage – First Shift – Last Month",
   "description": "Modbus 411954; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 115,
   "name": "Energy Apparent 3-Phase Total Usage – Second Shift – Last Month",
   "description": "Modbus 411956; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 116,
   "name": "Energy Apparent 3-Phase Total Usage – Third Shift – Last Month",
   "description": "Modbus 411958; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 117,
   "name": "THD/thd Current Phase A",
   "description": "Modbus 411960; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 118,
   "name": "THD/thd Current Phase B",
   "description": "Modbus 411962; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 119,
   "name": "THD/thd Current Phase C",
   "description": "Modbus 411964; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 120,
   "name": "THD/thd Current Phase N",
   "description": "Modbus 411966; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 121,
   "name": "THD/thd Voltage Phase A-N",
   "description": "Modbus 411968; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 122,
   "name": "THD/thd Voltage Phase B-N",
   "description": "Modbus 411970; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 123,
   "name": "THD/thd Voltage Phase C-N",
   "description": "Modbus 411972; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 124,
   "name": "THD/thd Voltage Phase A-B",
   "description": "Modbus 411974; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 125,
   "name": "THD/thd Voltage Phase B-C",
   "description": "Modbus 411976; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  },
  {
   "type": "AI",
   "instance": 126,
   "name": "THD/thd Voltage Phase C-A",
   "description": "Modbus 411978; not polled by default",
   "units": "",
   "access": "R",
   "states": ""
  }
 ],
 "page": "https://easybacnet.com/bacnet-points-lists/contemporary-controls/basgatewaylx-schneider-pm800",
 "note": "Provided as-is. Point availability varies by firmware and options; verify against the live device.",
 "disclaimer": "DISCLAIMER: reference only, provided AS IS with no warranty. May contain errors or be out of date. You must verify every point against the manufacturer's current documentation and the live device before use. easybacnet.com accepts no liability for its use and is not affiliated with the manufacturer. Terms: https://easybacnet.com/terms#content"
}